Literature DB >> 13819636

An experimental evaluation of the indicator dilution technique for the measurement of mitral regurgitation.

R H EICH, I STAIB, D ENERSON.   

Abstract

Entities:  

Keywords:  MITRAL VALVE/diseases

Mesh:

Year:  1959        PMID: 13819636      PMCID: PMC441791          DOI: 10.1172/JCI103982

Source DB:  PubMed          Journal:  J Clin Invest        ISSN: 0021-9738            Impact factor:   14.808


× No keyword cloud information.
  11 in total

1.  Some factors affecting indicator dilution curves in the presence and absence of valvular incompetence.

Authors:  J I HOFFMAN; G G ROWE
Journal:  J Clin Invest       Date:  1959-01-01       Impact factor: 14.808

2.  Clinical, physiological and pathological findings in mitral stenosis and regurgitation.

Authors:  L McDONALD; J B DEALY; M RABINOWITZ; L DEXTER
Journal:  Medicine (Baltimore)       Date:  1957-09       Impact factor: 1.889

3.  Dilution curves associated with valvular regurgitation.

Authors:  E WOODWARD; H B BURCHELL; E H WOOD
Journal:  Proc Staff Meet Mayo Clin       Date:  1957-09-18

4.  Evaluation of a method for detection of mitral regurgitation from indicator-dilution curves recorded from the left atrium.

Authors:  E WOODWARD; H J SWAN; E H WOOD
Journal:  Proc Staff Meet Mayo Clin       Date:  1957-09-18

5.  Hemodynamic methods for differentiation of mitral stenosis and regurgitation.

Authors:  H W MARSHALL; E WOODWARD; E H WOOD
Journal:  Am J Cardiol       Date:  1958-07       Impact factor: 2.778

6.  Further observations on the estimation of valvular incompetence from indicator dilution curves.

Authors:  P I KORNER; J P SHILLINGFORD
Journal:  Clin Sci       Date:  1956-08       Impact factor: 6.124

7.  The quantitative estimation of valvular incompetence by dye dilution curves.

Authors:  P I KORNER; J P SHILLINGFORD
Journal:  Clin Sci       Date:  1955-08       Impact factor: 6.124

8.  Estimations of cardiac output and central blood volume by dye dilution.

Authors:  P DOW
Journal:  Physiol Rev       Date:  1956-01       Impact factor: 37.312

9.  Definition of terms and symbols for description of circulatory indicator-dilution curves.

Authors:  E H WOOD; H J SWAN
Journal:  J Appl Physiol       Date:  1954-06       Impact factor: 3.531

10.  An evaluation of the measurement of the cardiac output and of the so-called pulmonary blood volume by the dye-dilution method.

Authors:  J T DOYLE; J S WILSON; C LEPINE; J V WARREN
Journal:  J Lab Clin Med       Date:  1953-01
View more
  1 in total

1.  Accuracy of the transpulmonary ultrasound dilution method for detection of small anatomic shunts.

Authors:  R Saxena; N Krivitski; K Peacock; A Durward; J M Simpson; S M Tibby
Journal:  J Clin Monit Comput       Date:  2014-09-21       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.