Literature DB >> 13678088

Image annotation for conveying automated lung nodule detection results to radiologists.

Samuel G Armato1.   

Abstract

RATIONALE AND
OBJECTIVES: The author investigated the ability of automated techniques to convey the results of an automated lung nodule detection method for human visualization.
MATERIALS AND METHODS: Automated nodule detection begins with gray-level thresholding techniques to create a segmented lung volume within which nodule candidates are identified. Morphologic and gray-level features are computed for each candidate. To distinguish between candidates that represent actual nodules and those that represent non-nodules, a rule-based scheme is combined with linear discriminant analysis. For output visualization, final detection results are represented as circles around computer-detected structures in a single section in which each structure appears. Consequently, an inappropriate choice of section could result in an actual nodule detected by the computer but not properly indicated to the radiologist, thus reducing the potential positive impact of that detection on the radiologist's decision-making process.
RESULTS: The automated nodule detection method achieved 71% sensitivity with 0.5 false positives per section on 38 CT scans; however, when these results were converted to annotations on the images output for human visualization, only 91% of the computer-detected true-positive nodules received annotations that encompassed a portion of the actual nodule. Thus, the "effective sensitivity" of the automated detection method was reduced.
CONCLUSION: The "effective sensitivity" of an automated lung nodule detection system considers the eventual human interaction with system output. Differences between reported computer sensitivity and "effective sensitivity" may be reduced through proper consideration of the assessment of "truth," of the manner in which computer results are scored, and of the complete segmentation of candidates for automated nodule detection.

Entities:  

Mesh:

Year:  2003        PMID: 13678088     DOI: 10.1016/s1076-6332(03)00116-8

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  3 in total

1.  iPad: Semantic annotation and markup of radiological images.

Authors:  Daniel L Rubin; Cesar Rodriguez; Priyanka Shah; Chris Beaulieu
Journal:  AMIA Annu Symp Proc       Date:  2008-11-06

2.  Evaluation of computer-aided detection and diagnosis systems.

Authors:  Nicholas Petrick; Berkman Sahiner; Samuel G Armato; Alberto Bert; Loredana Correale; Silvia Delsanto; Matthew T Freedman; David Fryd; David Gur; Lubomir Hadjiiski; Zhimin Huo; Yulei Jiang; Lia Morra; Sophie Paquerault; Vikas Raykar; Frank Samuelson; Ronald M Summers; Georgia Tourassi; Hiroyuki Yoshida; Bin Zheng; Chuan Zhou; Heang-Ping Chan
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

Review 3.  Segmentation and Image Analysis of Abnormal Lungs at CT: Current Approaches, Challenges, and Future Trends.

Authors:  Awais Mansoor; Ulas Bagci; Brent Foster; Ziyue Xu; Georgios Z Papadakis; Les R Folio; Jayaram K Udupa; Daniel J Mollura
Journal:  Radiographics       Date:  2015 Jul-Aug       Impact factor: 5.333

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.