Literature DB >> 1356186

Early detection of antibodies to HIV-1 by third-generation assays.

H L Zaaijer1, P v Exel-Oehlers, T Kraaijeveld, E Altena, P N Lelie.   

Abstract

Third-generation immunoassays for detection of antibody to human immunodeficiency virus (HIV) have reduced the interval between infection and antibody detection. Might such earlier detection diminish the value of the western blot as a confirmatory assay? We compared the sensitivity of one second-generation and two third-generation anti-HIV enzyme immunoassays (EIAs) with the results from HIV-antigen testing and western blot. 1045 western-blot confirmed anti-HIV positive samples were tested with a detection rate of 100% for all three EIAs. The detection rate in 36 samples drawn from different persons in early stages of HIV infection was 89% for the second-generation EIA and 94% for both third-generation EIAs. With carefully selected seroconversion panels that included sampling intervals during seroconversion of one week or less, we found that both third-generation EIAs detected seroconversion on average 5 days earlier (range 0-13) than did the second-generation assay. Western blot is commonly used to confirm HIV infection. In 6 of 10 seroconversions, one or both third-generation EIAs were reactive before any band appeared in the western blot. Since HIV antigen was detectable in these cases, the HIV antigen test may serve as a confirmatory assay for anti-HIV EIA-positive, western-blot negative, samples.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1356186     DOI: 10.1016/0140-6736(92)92303-w

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  23 in total

1.  Performance of a multiplex qualitative PCR LCx assay for detection of human immunodeficiency virus type 1 (HIV-1) group M subtypes, group O, and HIV-2.

Authors:  K Abravaya; C Esping; R Hoenle; J Gorzowski; R Perry; P Kroeger; J Robinson; R Flanders
Journal:  J Clin Microbiol       Date:  2000-02       Impact factor: 5.948

2.  Multicenter evaluation of new double-antigen sandwich enzyme immunoassay for measurement of anti-human immunodeficiency virus type 1 and type 2 antibodies.

Authors:  P Burgisser; F Simon; M Wernli; T Wust; M F Beya; P C Frei
Journal:  J Clin Microbiol       Date:  1996-03       Impact factor: 5.948

3.  Usefulness of enzyme immunoassay (EIA) for screening of anti HIV antibodies in urinary specimens: A comparative analysis.

Authors:  A K Sahni; A Nagendra; Partha Roy; S Patrikar
Journal:  Med J Armed Forces India       Date:  2013-12-16

4.  Multicenter evaluation of the new automated Enzymun-Test Anti-HIV 1 + 2 + subtyp O.

Authors:  B Weber
Journal:  J Clin Microbiol       Date:  1998-02       Impact factor: 5.948

5.  Human Immunodeficiency Virus (HIV).

Authors: 
Journal:  Transfus Med Hemother       Date:  2016-05-09       Impact factor: 3.747

6.  Synthetic-peptide-based enzyme-linked immunosorbent assay for screening human serum or plasma for antibodies to human immunodeficiency virus type 1 and type 2.

Authors:  L Gonzalez; R W Boyle; M Zhang; J Castillo; S Whittier; P Della-Latta; L M Clarke; J R George; X Fang; J G Wang; B Hosein; C Y Wang
Journal:  Clin Diagn Lab Immunol       Date:  1997-09

Review 7.  ENZYME LINKED IMMUNOSORBENT ASSAYS REVISITED.

Authors:  Mkk Rao; K Kapila; R M Gupta
Journal:  Med J Armed Forces India       Date:  2017-06-26

8.  Performance characteristics of recombinant enzyme immunoassay to detect antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 and to measure early antibody responses in seroconverting patients.

Authors:  R A Galli; S Castriciano; M Fearon; C Major; K W Choi; J Mahony; M Chernesky
Journal:  J Clin Microbiol       Date:  1996-04       Impact factor: 5.948

9.  Detection of human immunodeficiency virus type 1 (HIV-1) RNA in pools of sera negative for antibodies to HIV-1 and HIV-2.

Authors:  P A Morandi; G A Schockmel; S Yerly; P Burgisser; P Erb; L Matter; R Sitavanc; L Perrin
Journal:  J Clin Microbiol       Date:  1998-06       Impact factor: 5.948

10.  Evidence-based guidelines for universal counselling and offering of HIV testing in pregnancy in Canada.

Authors:  L Samson; S King
Journal:  CMAJ       Date:  1998-06-02       Impact factor: 8.262

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.