Literature DB >> 1332575

In situ hybridization for the detection of human papillomavirus (HPV) in gynaecological biopsies. A study of two commercial kits.

I Zehbe1, E Rylander, A Strand, E Wilander.   

Abstract

Human papillomavirus (HPV) detection in biopsies from the lower genital tract may be requested by clinicians as a complement to ordinary histopathological diagnosis. In the present study, two commercial kits, (Enzo Diagnostics Inc., New York, USA and Biohit, Helsinki, Finland) used for in situ hybridization with biotinylated c-DNA probes were compared and the HPV-expression was evaluated in relation to histopathological findings. The Enzo kit identifies HPV-types 6/11, 16/18, 18 and 31/33/51, whereas the Biohit kit has separate probes for HPV 6, 11, 16, 18, 31 and 33, but none for HPV 51. The usefulness of a general probe (probemix) for the visualization of HPV irrespective of type (Enzo Diagnostics Inc.) was also studied Altogether 226 biopsies from the lower female genital tract were formalin-fixed, paraffin-embedded and processed for routine histopathological grading. Consecutive sections were employed for in situ hybridization. 50 biopsies were subject to double-testing with Enzo and Biohit, whereas 176 were tested with Enzo only. Of the double-tested biopsies, 30% displayed a nuclear staining with the Enzo kit and 28% with the Biohit kit. It is concluded that the probes of these two kits have the same sensitivity in detecting HPV in tissue sections. Condylomata acuminata were HPV-positive in 81%, mostly for types 6/11. Flat condylomas were HPV-positive in 35%. The HPV-positivity of biopsies with low grade SIL (I) was 50% and that of high grade SIL (II and III) was 37%. High grade SIL contained either HPV-types 16/18 or 31/33/51. A correlation was found between the occurrence of koilocytosis and the presence of HPV-DNA. HPV-expression was most easily visualized in condylomata acuminata. In epithelium of normal appearance or with inflammatory alterations HPV-DNA was not seen.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1332575

Source DB:  PubMed          Journal:  Anticancer Res        ISSN: 0250-7005            Impact factor:   2.480


  2 in total

1.  Use of Probemix and OmniProbe biotinylated cDNA probes for detecting HPV infection in biopsy specimens from the genital tract.

Authors:  I Zehbe; E Rylander; A Strand; E Wilander
Journal:  J Clin Pathol       Date:  1993-05       Impact factor: 3.411

2.  Detection of human papillomavirus in cervical intra-epithelial neoplasia, using in situ hybridization and various polymerase chain reaction techniques.

Authors:  I Zehbe; E Rylander; K Edlund; G Wadell; E Wilander
Journal:  Virchows Arch       Date:  1996-06       Impact factor: 4.064

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.