Literature DB >> 1327796

An evaluation of Technegas as a ventilation agent compared with krypton-81 m in the scintigraphic diagnosis of pulmonary embolism.

G Cook1, S E Clarke.   

Abstract

A ventilation agent that provides good quality lung images, which is cheap, easy to use and non-toxic, with a low radiation dose, has long been sought. Technegas, an ultrafine aerosol of technetium-99m-labelled carbon, was developed with these qualities in mind. We have studied Technegas in a clinical setting to evaluate some of these qualities. Twenty-five patients referred with a diagnosis of suspected pulmonary embolism were investigated during the same study using both krypton-81 m and Technegas as ventilation agents in conjunction with 99mTc-macroaggregated albumin as a perfusion agent. Technegas provided images which were of satisfactory quality. Images were obtained relatively easily and without discomfort to the patient, and Technegas has the advantage of always being available. A semi-quantitative regional assessment was employed which showed a good correlation (r = 0.499, P less than 0.001) between Technegas and krypton-81 m ventilation. We report on an effect not previously found to be significant, that is lung regions were better ventilated with Technegas than with krypton-81 m. This altered the diagnostic probability rating of pulmonary embolism in a number of patients (n = 3, 12%) compared with krypton-81 m. This effect was also noted in a further 8 patients (32%) without a change in the diagnostic probability. We offer possible explanations for this phenomenon.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1327796     DOI: 10.1007/bf00182818

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  21 in total

1.  Assessment of regional ventilation by continuous inhalation of radioactive krypton-81m.

Authors:  F Fazio; T Jones
Journal:  Br Med J       Date:  1975-09-20

2.  Commentary. Clinical experience with technegas.

Authors:  I P Murray
Journal:  Clin Nucl Med       Date:  1991-04       Impact factor: 7.794

3.  Technegas--a new ventilation agent for lung scanning.

Authors:  W M Burch; P J Sullivan; C J McLaren
Journal:  Nucl Med Commun       Date:  1986-12       Impact factor: 1.690

4.  The particle size distribution of technegas and its influence on regional lung deposition.

Authors:  J C Strong; J E Agnew
Journal:  Nucl Med Commun       Date:  1989-06       Impact factor: 1.690

Review 5.  Pulmonary embolism: diagnosis with multiple imaging modalities.

Authors:  P O Alderson; E C Martin
Journal:  Radiology       Date:  1987-08       Impact factor: 11.105

6.  Effect of inspiratory flow rate on regional distribution of inspired gas.

Authors:  B Bake; L Wood; B Murphy; P T Macklem; J Milic-Emili
Journal:  J Appl Physiol       Date:  1974-07       Impact factor: 3.531

7.  Comparison of technetium-99m aerosol and krypton-81m in ventilation studies for the diagnosis of pulmonary embolism.

Authors:  P Peltier; P De Faucal; A Chetanneau; J F Chatal
Journal:  Nucl Med Commun       Date:  1990-09       Impact factor: 1.690

8.  Lung ventilation scanning with a new carbon particle radioaerosol (Technegas). Preliminary patient studies.

Authors:  D S Rimkus; W L Ashburn
Journal:  Clin Nucl Med       Date:  1990-04       Impact factor: 7.794

9.  Tc-99m-DTPA aerosol and radioactive gases compared as adjuncts to perfusion scintigraphy in patients with suspected pulmonary embolism.

Authors:  P O Alderson; D R Biello; A Gottschalk; P B Hoffer; S A Kroop; M E Lee; L Ramanna; B A Siegel; A D Waxman
Journal:  Radiology       Date:  1984-11       Impact factor: 11.105

10.  An improved radionuclide technique for the detection of altered pulmonary permeability.

Authors:  P Monaghan; I Provan; C Murray; D W Mackey; H Van der Wall; B M Walker; P D Jones
Journal:  J Nucl Med       Date:  1991-10       Impact factor: 10.057

View more
  6 in total

1.  EANM guidelines for ventilation/perfusion scintigraphy : Part 1. Pulmonary imaging with ventilation/perfusion single photon emission tomography.

Authors:  M Bajc; J B Neilly; M Miniati; C Schuemichen; M Meignan; B Jonson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-08       Impact factor: 9.236

Review 2.  Aerosols for therapy and diagnosis.

Authors:  M J O'Doherty; R F Miller
Journal:  Eur J Nucl Med       Date:  1993-12

3.  Technegas wash-in to confirm lung pathology?

Authors:  W M Burch
Journal:  Eur J Nucl Med       Date:  1993-04

4.  Joint Guideline on Venous Thromboembolism - 2022.

Authors:  Ana Cristina Lopes Albricker; Cláudia Maria Vilas Freire; Simone Nascimento Dos Santos; Monica Luiza de Alcantara; Mohamed Hassan Saleh; Armando Luis Cantisano; José Aldo Ribeiro Teodoro; Carmen Lucia Lascasas Porto; Salomon Israel do Amaral; Orlando Carlos Gloria Veloso; Ana Cláudia Gomes Pereira Petisco; Fanilda Souto Barros; Márcio Vinícius Lins de Barros; Adriano José de Souza; Marcone Lima Sobreira; Robson Barbosa de Miranda; Domingos de Moraes; Carlos Gustavo Yuji Verrastro; Alexandre Dias Mançano; Ronaldo de Souza Leão Lima; Valdair Francisco Muglia; Cristina Sebastião Matushita; Rafael Willain Lopes; Artur Martins Novaes Coutinho; Diego Bromfman Pianta; Alair Augusto Sarmet Moreira Damas Dos Santos; Bruno de Lima Naves; Marcelo Luiz Campos Vieira; Carlos Eduardo Rochitte
Journal:  Arq Bras Cardiol       Date:  2022-04       Impact factor: 2.000

5.  Ventilation/Perfusion SPECT for Diagnosis of Pulmonary Embolism and Other Diseases.

Authors:  Marika Bajc; Björn Jonson
Journal:  Int J Mol Imaging       Date:  2010-12-19

6.  Comparison of 81mKrypton and 99mTc-Technegas for ventilation single-photon emission computed tomography in severe chronic obstructive pulmonary disease.

Authors:  Robin de Nijs; Nienke D Sijtsema; Matthijs F Kruis; Claus Verner Jensen; Martin Iversen; Michael Perch; Jann Mortensen
Journal:  Nucl Med Commun       Date:  2021-02-01       Impact factor: 1.698

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.