Literature DB >> 1325971

Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies.

O Böstman1, U Päivärinta, E Partio, J Vasenius, M Manninen, P Rokkanen.   

Abstract

Degradation and tissue replacement of a totally absorbable polyglycolide screw, 4.5 millimeters in diameter and thirty millimeters in length, were studied histologically, morphometrically, and radiographically at sequential stages of resorption at as long as thirty-six weeks after fixation of a transverse distal femoral osteotomy in rabbits. The initial mean shear force to failure was 95.0 newtons for the specimens that had been fixed with the polyglycolide screw compared with 257.0 newtons for the distal part of the contralateral, intact femur. The physical appearance of the screw was unaltered at three weeks. The first histological signs of degradation were seen at six weeks, along the thread ridge. Premature breakage of the screw resulted in gross displacement and non-union of the osteotomy in one animal. The degradation of polyglycolide was accompanied histologically by a typical non-specific foreign-body reaction. This kind of tissue response seemed to be associated with an osteolytic proximal expansion of the implant cavity that was suggestive of increased pressure within the cavity during degradation of the screw. In eight specimens, a wall of new bone formed around this area of osteolysis and demarcated the implant cavity from the surrounding normal cancellous bone. Seventy-four per cent of the periphery and 28 per cent of the central core of the screw had been resorbed at twelve weeks. At thirty-six weeks, no polymeric material could be discerned, and the predominant tissue component within the implant cavity was loose connective tissue. The volume fractions of trabecular bone and hematopoietic bone marrow were significantly lower (p less than 0.01) than those of the intact, control side, but the degree of restoration of tissue varied considerably from animal to animal.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1325971

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  12 in total

1.  Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70:30/bioactive glass composite rods. An experimental study on rats.

Authors:  Pyhältö Tuomo; Lapinsuo Matti; Pätiälä Hannu; Rokkanen Pentti; Niiranen Henna; Törmälä Pertti
Journal:  J Mater Sci Mater Med       Date:  2004-03       Impact factor: 3.896

2.  Degradation, cytotoxicity, and biocompatibility of NIPAAm-based thermosensitive, injectable, and bioresorbable polymer hydrogels.

Authors:  Zhanwu Cui; Bae Hoon Lee; Christine Pauken; Brent L Vernon
Journal:  J Biomed Mater Res A       Date:  2011-05-04       Impact factor: 4.396

3.  Tissue restoration after implantation of polyglycolide, polydioxanone, polylevolactide, and metallic pins in cortical bone: an experimental study in rabbits.

Authors:  Harri K Pihlajamäki; Sari T Salminen; Olli Tynninen; Ole M Böstman; Outi Laitinen
Journal:  Calcif Tissue Int       Date:  2010-05-22       Impact factor: 4.333

4.  Intraosseous foreign body granuloma in rotator cuff repair with bioabsorbable suture anchor.

Authors:  T Nusselt; S Freche; H-M Klinger; M H Baums
Journal:  Arch Orthop Trauma Surg       Date:  2010-06-06       Impact factor: 3.067

Review 5.  Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction.

Authors:  Pedro Debieux; Carlos E S Franciozi; Mário Lenza; Marcel Jun Tamaoki; Robert A Magnussen; Flávio Faloppa; João Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2016-07-24

6.  Absorbable self-reinforced polylactide (SR-PLLA) rods vs rigid rods (K-wire) in spinal fusion: an experimental study in rabbits.

Authors:  Murat Bezer; Yakup Yildirim; Bülent Erol; Osman Güven
Journal:  Eur Spine J       Date:  2004-09-18       Impact factor: 3.134

7.  Fixation of experimental osteotomies with bioabsorbable SR-polylactide-polyglycolide (80/20) polymeric rods.

Authors:  Eeva Mäkelä; E Antero Mäkelä; Esa K Partio; Timo Juutilainen; Kimmo Lähteenkorva; Pertti Törmälä; Pentti Rokkanen
Journal:  J Mater Sci Mater Med       Date:  2007-08-15       Impact factor: 3.896

8.  Axial forces and bending moments in the loaded rabbit tibia in vivo.

Authors:  Janin Reifenrath; Daniel Gottschalk; Nina Angrisani; Silke Besdo; Andrea Meyer-Lindenberg
Journal:  Acta Vet Scand       Date:  2012-03-30       Impact factor: 1.695

Review 9.  The Use of Poly-d,l-lactic Acid (PDLLA) Devices for Bone Augmentation Techniques: A Systematic Review.

Authors:  Marco Annunziata; Livia Nastri; Gennaro Cecoro; Luigi Guida
Journal:  Molecules       Date:  2017-12-13       Impact factor: 4.411

Review 10.  Biomaterials-Driven Sterile Inflammation.

Authors:  Henry Chen; Devendra K Agrawal; Finosh G Thankam
Journal:  Tissue Eng Part B Rev       Date:  2021-02-23       Impact factor: 6.389