Literature DB >> 12975572

Diagnostic value of single versus dual chamber electrograms recorded from an implantable defibrillator.

Michael H Kim1, David Bruckman, Christian Sticherling, Hakan Oral, Frank Pelosi, Bradley P Knight, Fred Morady, S Adam Strickberger.   

Abstract

INTRODUCTION: The clinical utility of ventricular electrograms in comparison to atrial and ventricular electrograms in diagnosing the type of tachycardias recorded by an implantable defibrillator has not been addressed from the standpoint of a clinician's diagnostic accuracy and confidence in that diagnosis.
METHODS: Fifty-two tachycardia episodes recorded from dual chamber defibrillators were divided into two tests. The initial test contained only information from the ventricular electrogram and the second test contained information from both the atrial and ventricular electrograms. For each test, the reviewers were asked to provide the specific diagnosis, the originating chamber of origin of the tachycardia, and the confidence of their responses for each question. McNemar's test for matched pairs was used to determine accuracy and an analysis of variance to determine reviewer confidence.
RESULTS: The overall accuracy for both the specific diagnosis (61% vs. 79%; p < 0.001) and the chamber of origin (76% vs. 90%; p < 0.001) improved when both the atrial and ventricular electrograms were available for review. Reviewer confidence appeared to correlate with diagnostic accuracy.
CONCLUSIONS: The data clearly show the favorable impact of dual chamber defibrillators on the diagnostic accuracy and confidence of clinicians faced with a clinical tachycardia recorded from an implantable defibrillator. Such improvements may translate into more focused and appropriate therapeutic interventions.

Entities:  

Mesh:

Year:  2003        PMID: 12975572     DOI: 10.1023/a:1025324621737

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  5 in total

1.  Preliminary clinical experience with the first dual chamber pacemaker defibrillator.

Authors:  T Lavergne; J C Daubert; M Chauvin; E Dolla; S Kacet; A Leenhardt; P Mabo; P Ritter; N Sadoul; N Saoudi; C Henry; R Nitzsche; A Ripart; F Murgatroyd
Journal:  Pacing Clin Electrophysiol       Date:  1997-01       Impact factor: 1.976

2.  Do current dual chamber cardioverter defibrillators have advantages over conventional single chamber cardioverter defibrillators in reducing inappropriate therapies? A randomized, prospective study.

Authors:  I Deisenhofer; C Kolb; G Ndrepepa; J Schreieck; M Karch; S Schmieder; B Zrenner; C Schmitt
Journal:  J Cardiovasc Electrophysiol       Date:  2001-02

3.  Clinical experience with the new detection algorithms for atrial fibrillation of a defibrillator with dual chamber sensing and pacing.

Authors:  V Kühlkamp; V Dörnberger; C Mewis; R Suchalla; R F Bosch; L Seipel
Journal:  J Cardiovasc Electrophysiol       Date:  1999-07

4.  Inappropriate detection of supraventricular arrhythmias by implantable dual chamber defibrillators: a comparison of four different algorithms.

Authors:  F Hintringer; S Schwarzacher; G Eibl; O Pachinger
Journal:  Pacing Clin Electrophysiol       Date:  2001-05       Impact factor: 1.976

5.  Implantable cardioverter-defibrillator therapy in the absence of significant symptoms. Rhythm diagnosis and management aided by stored electrogram analysis.

Authors:  B G Hook; D J Callans; R B Kleiman; B T Flores; F E Marchlinski
Journal:  Circulation       Date:  1993-06       Impact factor: 29.690

  5 in total
  2 in total

Review 1.  "Two for the Price of One": A Single-Lead Implantable Cardioverter-Defibrillator System with a Floating Atrial Dipole.

Authors:  Nicole E Worden; Musab Alqasrawi; Siva M Krothapalli; Alexander Mazur
Journal:  J Atr Fibrillation       Date:  2016-04-30

2.  [Sandwiched between the single- and triple-chamber ICD: do we still need the dual-chamber ICD?].

Authors:  C W Israel
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-12
  2 in total