Literature DB >> 12973293

Residual dentin thickness in mesial roots of mandibular molars prepared with Lightspeed rotary instruments and Gates-Glidden reamers.

Offer Zuckerman1, Alexander Katz, Raphael Pilo, Aviad Tamse, Zvi Fuss.   

Abstract

OBJECTIVE: We sought to measure the residual dentin thickness (RDT) in the mesial roots of mandibular molars after instrumentation with Lightspeed and Gates-Glidden rotary instruments. Study design Thirty extracted, untreated human mesial roots of mandibular molars were separated from the distal roots and embedded in clear polyester resin. The roots were cut horizontally at 1, 4, and 7 mm short of the anatomic apex. The diameter of each mesiobuccal canal was measured by using a stereo measuring microscope at each level in the buccolingual and mesiodistal directions. The dentin thickness was measured in each level in the mesial, distal, buccal, and lingual directions. Sections were reassembled with a muffle. The canals were enlarged to the working length with Lightspeed rotary instruments, of which the average size used was a No. 50 file. The coronal third was flared with No. 2 Gates-Glidden reamers. Slices were separated again, and the RDT and canal diameters were measured.
RESULTS: The minimal measured RDT after instrumentation at the 1-, 4-, and 7-mm levels was 0.70 +/- 0.28 mm, 1.04 +/- 0.18 mm, and 1.09 +/- 0.19 mm, respectively. The average diameter of the canals after instrumentation at the 1-, 4-, and 7-mm levels was 0.50 +/- 0.04 mm, 0.52 +/- 0.05 mm, and 0.74 +/- 0.08 mm, respectively. The canal diameter did not exceed one third of the root diameter at all levels.
CONCLUSIONS: Root canal preparation of mandibular mesial roots with Lightspeed instruments to No. 50 in the apical third and Gates-Glidden reamers to No. 2 in the coronal third does not significantly decrease the RDT.

Entities:  

Mesh:

Year:  2003        PMID: 12973293     DOI: 10.1016/s1079-2104(02)91710-5

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  14 in total

1.  Computed tomography evaluation of residual root thickness after pre-flaring using gates Glidden drills: The sequence effect.

Authors:  Nahid M Akhlaghi; Amirali Naghdi; Laleh Mohammadian Bajgiran; Elahe Behrooz
Journal:  J Conserv Dent       Date:  2014-03

2.  A digital stereomicroscopic study of the furcation wall thickness of mesiobuccal roots of maxillary first and second molars.

Authors:  Arash Shahravan; Alireza Rekabi; Hasan Shahabi; Rezvan Ashuri; Ali Mirzazadeh; Maryam Rad; Jahangir Haghani
Journal:  Iran Endod J       Date:  2010-05-20

3.  Comparison of the effects of TripleGates and Gates-Glidden burs on cervical dentin thickness and root canal area by using cone beam computed tomography.

Authors:  Kássio Sousa; Carlos Vieira Andrade-Junior; Juliana Melo da Silva; Marco Antonio Hungaro Duarte; Gustavo De-Deus; Emmanuel João Nogueira Leal da Silva
Journal:  J Appl Oral Sci       Date:  2015 Mar-Apr       Impact factor: 2.698

4.  The minimum residual root thickness after using ProTaper, RaCe and Gates-Glidden drills: A cone beam computerized tomography study.

Authors:  Nahid Mohammadzadeh Akhlaghi; Laleh Mohammadian Bajgiran; Amirali Naghdi; Elaheh Behrooz; Zohreh Khalilak
Journal:  Eur J Dent       Date:  2015 Apr-Jun

5.  Endodontic treatment of a C-shaped mandibular second premolar with four root canals and three apical foramina: a case report.

Authors:  Thikamphaa Bertrand; Sahng Gyoon Kim
Journal:  Restor Dent Endod       Date:  2016-01-19

6.  A Digital Stereomicroscopic Study of the Radicular Wall Thickness of Two-Canal Mandibular Incisors.

Authors:  Sedigheh Khedmat; Sohayla Mohamadian; Fatemeh Dibaji; Mohamad Javad Kharrazifard
Journal:  J Dent (Tehran)       Date:  2015-07

7.  Cervical Dentin Changes in Curved Root Canals after Using WaveOne and Reciproc Files with Full Rotation versus Reciprocation Movement: An Ex vivo Study.

Authors:  Yazdan Shantiaee; Golnaz Nahvi; Omid Dianat; Farzad Aghdashi
Journal:  Contemp Clin Dent       Date:  2017 Jul-Sep

8.  The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique.

Authors:  Qian Yang; Gary Shun-Pan Cheung; Ya Shen; Dingming Huang; Xuedong Zhou; Yuan Gao
Journal:  BMC Oral Health       Date:  2015-07-28       Impact factor: 2.757

9.  Alterations of the Danger Zone after Preparation of Curved Root Canals Using WaveOne with Reverse Rotation or Reciprocation Movements.

Authors:  Yazdan Shantiaee; Omid Dianat; Payam Paymanpour; Golnaz Nahvi; Mohammad Ali Ketabi; Golbarg Kolahi Ahari
Journal:  Iran Endod J       Date:  2015-07-01

10.  Comparison of removed dentin thickness with hand and rotary instruments.

Authors:  Shahriar Shahriari; Hasan Abedi; Mahdi Hashemi; Seyed Mohsen Jalalzadeh
Journal:  Iran Endod J       Date:  2009-04-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.