Six cases of bacterial infection in porous orbital implants.

Jung-Ran You1, Jin-Ho Seo, Yeong-Hoon Kim, Woong-Chul Choi.   

Abstract

BACKGROUND: We present 6 cases of bacterial infection that developed after porous orbital implant surgery. CASES: Five patients with hydroxyapatite implants showed lid swelling, discharge, and suppurative granuloma 14 days to 3 years after surgery. The hydroxyapatite implants were removed 14 days to 41 months postoperatively, and synthetic porous polyethylene orbital implants were inserted. Thick discharge and conjunctival melting was noted 14 months after primary Medpor implant surgery in the sixth patient, and the infection was controlled by medical therapy. OBSERVATIONS: The culture of specimens removed with swabs from the conjunctiva of patients and from the hydroxyapatite implants showed growth of Staphylococcus aureus, Staphylococcus epidermidis, alpha-hemolytic streptococcus and peptostreptococcus in 4 patients, whereas Streptococcus pyogenes were cultured from the conjunctiva in the Medpor implant patient. Culture for the remaining patient was negative .
CONCLUSIONS: If there is continuous pain, injection, and discharge after porous implant insertion, bacterial infection in the implant should be considered immediately. Systemic antibiotics and topical eye drops should be administered without delay. If no improvement is observed, the implant should be removed and a different approach must be considered.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12967870     DOI: 10.1016/s0021-5155(03)00137-0

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  4 in total

1.  [Craniofacial augmentation with porous polyethylene implants (Medpor: first clinical results].

Authors:  M Gosau; S Schiel; G F Draenert; S Ihrler; G Mast; M Ehrenfeld
Journal:  Mund Kiefer Gesichtschir       Date:  2006-05

2.  Long-term surgical outcomes of porous polyethylene orbital implants: a review of 314 cases.

Authors:  Su-Kyung Jung; Won-Kyung Cho; Ji-Sun Paik; Suk-Woo Yang
Journal:  Br J Ophthalmol       Date:  2011-11-17       Impact factor: 4.638

3.  Safety and Biocompatibility of a New High-Density Polyethylene-Based Spherical Integrated Porous Orbital Implant: An Experimental Study in Rabbits.

Authors:  Ivan Fernandez-Bueno; Salvatore Di Lauro; Ivan Alvarez; Jose Carlos Lopez; Maria Teresa Garcia-Gutierrez; Itziar Fernandez; Eva Larra; Jose Carlos Pastor
Journal:  J Ophthalmol       Date:  2015-11-24       Impact factor: 1.909

4.  Complications of orbital endoimplantation in the Eye Clinic of the Lithuanian University of Health Sciences.

Authors:  Raimonda Piškinienė; Mantas Banevičius
Journal:  Acta Med Litu       Date:  2017
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.