Literature DB >> 12967759

Correction of axis misalignment in the analysis of knee rotations.

F Marin1, H Mannel, L Claes, L Dürselen.   

Abstract

The Cardanic or Eulerian description is the most commonly used method for the description of in vivo knee rotation. It is based on the determination of external anatomical landmarks used for the decomposition of the position of the tibia relative to the femur by three rotations about three pre-defined axes. However, the in vivo localisation of external anatomical landmarks is known to be difficult and subjective. Even a small mislocalisation may lead to dramatic consequences: the Cardanic description may become irreproducible and angle values may be overestimated. This error is well documented in the literature and known as the "cross-talk effect". Therefore this study proposes an additional calibration step of the classic Cardanic description by a reorientation procedure of rotation axes. The procedure is based on biomechanical constraints of knee kinematics as they appear during a knee squat exercise using the finite helical axis (FHA) method and is independent of anatomical landmark. The method was validated with the help of a special set-up modelling a perfect knee. Furthermore, an inter-session reliability study was performed involving tests on two healthy subjects during knee squat exercises. We found that the reorientation procedure was more reproducible than the classic Cardanic description. We observed a maximum inter-session difference of 37.1 degrees for the adduction angle obtained with the classic Cardanic description. In contrast, the maximum angle difference obtained with the reorientation procedure was less than 10 degrees.

Mesh:

Year:  2003        PMID: 12967759     DOI: 10.1016/s0167-9457(03)00036-8

Source DB:  PubMed          Journal:  Hum Mov Sci        ISSN: 0167-9457            Impact factor:   2.161


  8 in total

1.  Finite helical axes of motion are a useful tool to describe the three-dimensional in vitro kinematics of the intact, injured and stabilised spine.

Authors:  A Kettler; F Marin; G Sattelmayer; M Mohr; H Mannel; L Dürselen; L Claes; H J Wilke
Journal:  Eur Spine J       Date:  2004-05-18       Impact factor: 3.134

2.  The intertarsal joint of the ostrich (Struthio camelus): Anatomical examination and function of passive structures in locomotion.

Authors:  Nina U Schaller; Bernd Herkner; Rikk Villa; Peter Aerts
Journal:  J Anat       Date:  2009-06       Impact factor: 2.610

3.  Reconstructing the knee joint mechanism from kinematic data.

Authors:  Irene Reichl; Winfried Auzinger; Heinz-Bodo Schmiedmayer; Ewa Weinmüller
Journal:  Math Comput Model Dyn Syst       Date:  2010-11-20       Impact factor: 0.945

4.  Goniometer crosstalk compensation for knee joint applications.

Authors:  Tatiana de Oliveira Sato; Gert-Åke Hansson; Helenice Jane Cote Gil Coury
Journal:  Sensors (Basel)       Date:  2010-11-09       Impact factor: 3.576

5.  Cross-talk correction method for knee kinematics in gait analysis using principal component analysis (PCA): a new proposal.

Authors:  Audrey Baudet; Claire Morisset; Philippe d'Athis; Jean-Francis Maillefert; Jean-Marie Casillas; Paul Ornetti; Davy Laroche
Journal:  PLoS One       Date:  2014-07-08       Impact factor: 3.240

6.  Medial knee loading is altered in subjects with early osteoarthritis during gait but not during step-up-and-over task.

Authors:  Susana Meireles; Mariska Wesseling; Colin R Smith; Darryl G Thelen; Sabine Verschueren; Ilse Jonkers
Journal:  PLoS One       Date:  2017-11-08       Impact factor: 3.240

7.  Impact of knee marker misplacement on gait kinematics of children with cerebral palsy using the Conventional Gait Model-A sensitivity study.

Authors:  Mickael Fonseca; Xavier Gasparutto; Fabien Leboeuf; Raphaël Dumas; Stéphane Armand
Journal:  PLoS One       Date:  2020-04-24       Impact factor: 3.240

Review 8.  Sensor-to-Segment Calibration Methodologies for Lower-Body Kinematic Analysis with Inertial Sensors: A Systematic Review.

Authors:  Léonie Pacher; Christian Chatellier; Rodolphe Vauzelle; Laetitia Fradet
Journal:  Sensors (Basel)       Date:  2020-06-11       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.