Literature DB >> 12967070

Reliability of digital radiography of interproximal dental caries.

Etje Sanden1, Andreas Koob, Stefan Hassfeld, Hans Jörg Staehle, Peter Eickholz.   

Abstract

PURPOSE: To compare the effects of different image processing modes (filters) on the reproducibility and validity of the assessment of interproximal carious lesions viewed in digitized radiographic images.
MATERIALS AND METHODS: Variables studied were film type, exposure time, and tissue scatter radiation. Images were assessed in relation to film type, exposure time and tissue scatter. Standardized radiographs of 50 extracted teeth were obtained and 44 areas of interproximal caries were detected. Six radiographs were obtained of each tooth and digitized using FRIACOM software. Four were made using D-type film with and without soft tissue scatter equivalent at normal exposure time (0.32 seconds) and underexposed (0.16 seconds). Two were made using E-type film with TSE normal (0.16 seconds) and underexposed (0.08 seconds). On each of the 300 radiographs, the central depth (CD) of each carious lesion was measured at 18x magnification both on the unchanged radiographic image and after use of two different filters. All measurements were repeated after 1 week to estimate reproducibility.
RESULTS: Histometric CD assessments provided a gold standard for comparison with the radiographic measurements (validity). Whereas reproducibility was not influenced by one of the filters, filter "structure" improved the overall validity of CD measurements. In this study, digital manipulations of radiographic images resulted in statistically significant improvement of the validity of CD measurements.

Entities:  

Mesh:

Year:  2003        PMID: 12967070

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  5 in total

1.  Image quality assessment in panoramic dental radiography: a comparative study between conventional and digital systems.

Authors:  Akmal Sabarudin; Yu Jin Tiau
Journal:  Quant Imaging Med Surg       Date:  2013-02

2.  Performance of a photostimulable storage phosphor digital system with or without the sharpen filter and cone beam CT for detecting approximal enamel subsurface demineralization.

Authors:  M D F Belém; C P M Tabchoury; R I Ferreira-Santos; F C Groppo; F Haiter-Neto
Journal:  Dentomaxillofac Radiol       Date:  2013-02-14       Impact factor: 2.419

Review 3.  Radiographic modalities for diagnosis of caries in a historical perspective: from film to machine-intelligence supported systems.

Authors:  Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2021-03-04       Impact factor: 3.525

4.  Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography.

Authors:  Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli Da Silva; Liogi Iwaki Filho; Alfredo De Franco Queiroz; Lucas Bachegas Gomes Geron
Journal:  Contemp Clin Dent       Date:  2013-07

5.  Accuracy of digital image enhancement in detection of vertical and horizontal root fracture.

Authors:  Maryam Ghazizadeh; Mahnaz Sheikhi; Maedeh Aminian; Mohammad Moein Ghazizadeh
Journal:  Dent Res J (Isfahan)       Date:  2020-08-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.