Literature DB >> 12966290

Explicit finite element simulation of eccentric loading in total knee replacement.

M Taylor1, D S Barrett.   

Abstract

In vivo kinematic data indicate that unicondylar or edge loading occurs during normal activities in well-aligned and malpositioned knee replacements. Using a validated explicit finite element model of a knee replacement, the effects of eccentric loading of a total knee replacement are simulated. Only minor variations were observed in the kinematics with a medial offset of the vertical load of as much as 15 mm (representing a medial:lateral loading ratio of 86:14), although the polyethylene stresses did increase by approximately 3 MPa throughout the stance phase of gait. There was a significant change in the kinematics and stresses when unicondylar loading occurred (95:5 medial:lateral loading ratio). Even for the unicondylar load case, contact always was maintained within the lateral compartment. This raises the question whether lift-off often observed in fluoroscopy studies really occurs. The model predicted regions of plastic deformation that closely resemble those observed in retrieved specimens of catastrophic wear. The explicit finite element model offers considerable insight into the kinematics and stresses generated by total knee replacement during different and varied loading conditions that occur during normal usage.

Entities:  

Mesh:

Year:  2003        PMID: 12966290     DOI: 10.1097/01.blo.0000079267.91782.58

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  12 in total

1.  Kinematics of a highly congruent mobile-bearing total knee prosthesis.

Authors:  N Wolterbeek; E H Garling; B J A Mertens; H M J van der Linden; R G H H Nelissen; E R Valstar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-17       Impact factor: 4.342

2.  Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty.

Authors:  Tsan-Wen Huang; Kuo-Ti Peng; Kuo-Chin Huang; Mel S Lee; Robert Wen-Wei Hsu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-21       Impact factor: 4.342

3.  Correlation between in vivo stresses and oxidation of UHMWPE in total hip arthroplasty.

Authors:  M Regis; P Bracco; L Giorgini; S Fusi; P Dalla Pria; L Costa; C Schmid
Journal:  J Mater Sci Mater Med       Date:  2014-06-29       Impact factor: 3.896

4.  Damage in total knee replacements from mechanical overload.

Authors:  William F Zimmerman; Mark A Miller; Richard J Cleary; Timothy H Izant; Kenneth A Mann
Journal:  J Biomech       Date:  2016-05-20       Impact factor: 2.712

5.  Radiostereometric measurement of polyethylene deformation pattern in meniscal bearing TKR at 5 years follow-up.

Authors:  Alessandro Russo; Laura Bragonzoni; Claudia Trozzi; Francesco Iacono; Andrea Visani; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-11-16       Impact factor: 4.342

6.  A 3D finite element model to investigate prosthetic interface stresses of different posterior tibial slope.

Authors:  Yi Shen; Xiaomiao Li; Xiaodong Fu; Weili Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-07-30       Impact factor: 4.342

7.  The benefits of computer-assisted total knee arthroplasty on coronal alignment with marked femoral bowing in Asian patients.

Authors:  Chien-Yin Lee; Shih-Jie Lin; Liang-Tseng Kuo; Kuo-Ti Peng; Kuo-Chin Huang; Tsan-Wen Huang; Mel S Lee; Robert Wen-Wei Hsu; Wun-Jer Shen
Journal:  J Orthop Surg Res       Date:  2014-12-03       Impact factor: 2.359

8.  Comparison of computer-navigated and conventional total knee arthroplasty in patients with Ranawat type-II valgus deformity: medium-term clinical and radiological results.

Authors:  Tsan-Wen Huang; Chien-Yin Lee; Shih-Jie Lin; Kuo-Ti Peng; Kuo-Chin Huang; Mel S Lee; Robert Wen-Wei Hsu; Wun-Jer Shen
Journal:  BMC Musculoskelet Disord       Date:  2014-11-22       Impact factor: 2.362

9.  Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty.

Authors:  Shih-Jie Lin; Chien-Ying Lee; Kuo-Chin Huang; Kuo-Ti Peng; Tsan-Wen Huang; Mel S Lee; Robert Wen-Wei Hsu; Wun-Jer Shen
Journal:  J Orthop Surg Res       Date:  2015-09-02       Impact factor: 2.359

10.  The effect of malrotation of tibial component of total knee arthroplasty on tibial insert during high flexion using a finite element analysis.

Authors:  Kei Osano; Ryuji Nagamine; Mitsugu Todo; Makoto Kawasaki
Journal:  ScientificWorldJournal       Date:  2014-05-08
View more