Literature DB >> 12960526

Automatic model-based contour detection and blood flow quantification in small vessels with velocity encoded magnetic resonance imaging.

Frieke M A Box1, Aart Spilt, Mark A Van Buchem, Rob J van der Geest, Johan H C Reiber.   

Abstract

RATIONALE AND
OBJECTIVES: The quantitative assessment of blood flow in peripheral vessels from phase-contrast magnetic resonance imaging studies requires the accurate delineation of vessel contours in cross-sectional magnetic resonance images. The conventional manual segmentation approach is tedious, time-consuming, and leads to significant inter- and intraobserver variabilities. The aim of this study was to verify whether automatic model-based segmentation decreases these problems by fitting a model to the actual blood velocity profile.
METHODS: In this study 2 new fully automatic methods (a static and a dynamic approach) were developed and compared with manual analyzes using phantom and in vivo studies of internal carotid and vertebral arteries in healthy volunteers. The automatic segmentation approaches were based on fitting a 3D parabolic velocity model to the actual velocity profiles. In the static method, the velocity profiles were averaged over the complete cardiac cycle, whereas the dynamic method takes into account the velocity data of each cardiac time bin individually. Materials consisted of the magnetic resonance imaging data from 3 straight phantom tubes and the blood velocity profiles of 8 volunteers.
RESULTS: For the phantom studies, the automatic dynamic approach performed significantly better than the manual analysis (intraclass correlations [ICC] of 0.62-0.98 and 0.30-0.86, respectively). For the assessment of the total cerebral blood flow in the in vivo studies, the automatic static method performed significantly better than the manual 1 (ICC of 0.98-0.98 and 0.93-0.95, respectively). However, the automatic dynamic method was not significantly better than the manual 1 (ICC = 0.92-0.96) but had the advantage of providing additional parameters.
CONCLUSION: Blood flow in magnetic resonance images of small vessels can be assessed accurately, rapidly, and fully automatically using model-based postprocessing by fitting a first approximation of the velocity profile to the actual flow data.

Mesh:

Year:  2003        PMID: 12960526     DOI: 10.1097/01.RLI.0000077125.58014.36

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

1.  Semiautomatic analysis of phase contrast magnetic resonance imaging of cerebrospinal fluid flow through the aqueduct of Sylvius.

Authors:  Yudy Natalia Flórez; David Moratal; Juana Forner; Luis Martí-Bonmatí; Estanislao Arana; Ulises Guajardo-Hernández; José Millet-Roig
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

2.  MRI of arterial flow reserve in patients with intermittent claudication: feasibility and initial experience.

Authors:  Bas Versluis; Marjolein H G Dremmen; Patty J Nelemans; Joachim E Wildberger; Geert-Willem Schurink; Tim Leiner; Walter H Backes
Journal:  PLoS One       Date:  2012-03-08       Impact factor: 3.240

3.  Heritability and genome-wide associations studies of cerebral blood flow in the general population.

Authors:  M Arfan Ikram; Hazel I Zonneveld; Gennady Roshchupkin; Albert V Smith; Oscar H Franco; Sigurdur Sigurdsson; Cornelia van Duijn; André G Uitterlinden; Lenore J Launer; Meike W Vernooij; Vilmundur Gudnason; Hieab Hh Adams
Journal:  J Cereb Blood Flow Metab       Date:  2017-06-19       Impact factor: 6.200

4.  MRI evaluation of the relationship between carotid artery endothelial shear stress and brain white matter lesions in migraine.

Authors:  Evelien S Hoogeveen; Enrico B Arkink; Jeroen van der Grond; Mark A van Buchem; Michel D Ferrari; Gisela M Terwindt; Mark C Kruit
Journal:  J Cereb Blood Flow Metab       Date:  2019-06-18       Impact factor: 6.200

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.