Literature DB >> 12959292

Comparison of the extrapulmonary beta2-adrenoceptor responses and pharmacokinetics of salbutamol given by standard metered dose-inhaler and modified actuator device.

D M Newnham1, D G McDevitt, B J Lipworth.   

Abstract

1. Ten healthy subjects were randomised to inhale salbutamol via a standard metered-dose inhaler (MDI), or via a modified metered-dose actuator device (MA). Previously published radiolabelled aerosol data had shown that the MA device produced a lower aerosol velocity, reduced oropharyngeal deposition, but with unchanged pulmonary deposition. 2. Dose-response curves (DRC) were constructed with the following cumulative doses of salbutamol: 200 microg, 600 microg (200 microg + 400 microg), 1400 microg (600microg + 800 microg) ad 2600 microg (1400 + 1200 microg). Dose increments were made every 30 min and measurements of extrapulmonary beta2-adrenoceptor responses were performed 20 min after each dose. In addition, plasma salbutamol concentrations were also measured immediately before and for up to 60 min after the last dose. 3. Baseline values were not significantly different between the two study days for any of the measured parameters. 4. Cmax (ng ml(-1)) for plasma salbutamol (as means and 95% CI for difference between MA and MDI) was: 2.0 (0.3-3.7), P = 0.03. Values for t(max) (min), median and range: MA 5 (5-10) vs MDI 5 (5-10); and AUC 0-60, (ng ml(-1) min, mean and 95% CI for difference between MA and MDI): 69 (-5-143), were not significantly different between the two devices. 5. There was a significant (P < 0.01) left shift in the DRC with the MA device compared with the MDI, for hypokalaemic, finger tremor, chronotropic and electrocardiographic (Twave, Q-Tc) responses to salbutamol. Values for the hypokalaemic response (mmol l(-1)) at 2600 microg were (as change from baseline, means and 95% CI for difference between MA and MDI): 0.23 (0.10-0.36). 6. Thus, the MA device produced greater systemic absorption of salbutamol, and associated extrapulmonary beta2-adrenoceptor responses compared with a standard MDI. These results, therefore, suggest that data from radiolabelled aerosol deposition studies may not predict the systemic absorption of inhaled beta2-adrenoceptor agonists.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 12959292      PMCID: PMC1364617          DOI: 10.1111/j.1365-2125.1993.tb00393.x

Source DB:  PubMed          Journal:  Br J Clin Pharmacol        ISSN: 0306-5251            Impact factor:   4.335


  18 in total

1.  Beta-adrenoceptor responses to inhaled salbutamol in normal subjects.

Authors:  B J Lipworth; D G McDevitt
Journal:  Eur J Clin Pharmacol       Date:  1989       Impact factor: 2.953

2.  Bronchodilator delivery from Gentlehaler, a new low-velocity pressurized aerosol inhaler.

Authors:  S P Newman; S W Clarke
Journal:  Chest       Date:  1993-05       Impact factor: 9.410

3.  Comparison of three techniques of inhalation on the airway response to terbutaline.

Authors:  M J Cushley; R A Lewis; A E Tattersfield
Journal:  Thorax       Date:  1983-12       Impact factor: 9.139

4.  The efficacy of drug delivery by a pear-shaped spacer and metered dose inhaler.

Authors:  J Morris; J S Milledge; H Moszoro; A Higgins
Journal:  Br J Dis Chest       Date:  1984-10

5.  Improvement of pressurised aerosol deposition with Nebuhaler spacer device.

Authors:  S P Newman; A B Millar; T R Lennard-Jones; F Morén; S W Clarke
Journal:  Thorax       Date:  1984-12       Impact factor: 9.139

6.  Salbutamol aerosol causes a tachycardia due to the inhaled rather than the swallowed fraction.

Authors:  J G Collier; R J Dobbs; I Williams
Journal:  Br J Clin Pharmacol       Date:  1980-03       Impact factor: 4.335

7.  Inhalation of terbutaline sulphate through a conventional actuator or a pear-shaped tube: effects and side effects.

Authors:  S B Lindgren; S Larsson
Journal:  Eur J Respir Dis       Date:  1982-11

8.  Decreased adreno-cortical suppression utilizing the Nebuhaler for inhalation of steroid aerosols.

Authors:  P Prahl; T Jensen
Journal:  Clin Allergy       Date:  1987-09

9.  Systemic cardiovascular and metabolic effects associated with the inhalation of an increased dose of albuterol. Influence of mouth rinsing and gargling.

Authors:  M Küng; S W Croley; B A Phillips
Journal:  Chest       Date:  1987-03       Impact factor: 9.410

10.  Comparison of Nebuhaler and nebulizer treatment of acute severe asthma in children.

Authors:  G Fuglsang; S Pedersen
Journal:  Eur J Respir Dis       Date:  1986-08
View more
  14 in total

1.  Relative bioavailability of sodium cromoglycate to the lung following inhalation, using urinary excretion.

Authors:  O A Aswania; S A Corlett; H Chrystyn
Journal:  Br J Clin Pharmacol       Date:  1999-06       Impact factor: 4.335

Review 2.  Can lung deposition data act as a surrogate for the clinical response to inhaled asthma drugs?

Authors:  S P Newman
Journal:  Br J Clin Pharmacol       Date:  2000-06       Impact factor: 4.335

3.  Methods to determine lung distribution of inhaled drugs - could gamma scintigraphy be the gold standard?

Authors:  H Chrystyn
Journal:  Br J Clin Pharmacol       Date:  2000-06       Impact factor: 4.335

Review 4.  Methods to identify drug deposition in the lungs following inhalation.

Authors:  H Chrystyn
Journal:  Br J Clin Pharmacol       Date:  2001-04       Impact factor: 4.335

5.  Age dependent systemic exposure to inhaled salbutamol.

Authors:  Klaus Bønnelykke; Jakob Jessing Jespersen; Hans Bisgaard
Journal:  Br J Clin Pharmacol       Date:  2007-03-01       Impact factor: 4.335

Review 6.  Deposition and effects of inhaled corticosteroids.

Authors:  Stephen P Newman
Journal:  Clin Pharmacokinet       Date:  2003       Impact factor: 6.447

7.  Subsensitivity of bronchodilator and systemic beta 2 adrenoceptor responses after regular twice daily treatment with eformoterol dry powder in asthmatic patients.

Authors:  D M Newnham; A Grove; D G McDevitt; B J Lipworth
Journal:  Thorax       Date:  1995-05       Impact factor: 9.139

Review 8.  Optimizing inhaled drug delivery in patients with asthma.

Authors:  C Jackson; B Lipworth
Journal:  Br J Gen Pract       Date:  1995-12       Impact factor: 5.386

9.  Lung bioavailability of generic and innovator salbutamol metered dose inhalers.

Authors:  D J Clark; J Gordon-Smith; G McPhate; G Clark; B J Lipworth
Journal:  Thorax       Date:  1996-03       Impact factor: 9.139

Review 10.  Spacer devices for metered dose inhalers.

Authors:  Stephen P Newman
Journal:  Clin Pharmacokinet       Date:  2004       Impact factor: 6.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.