Literature DB >> 12956467

Closed posterior superior iliac spine impeding pediculocorporeal S-1 screw insertion.

Erkan Kaptanoglu1, Ozerk Okutan, Ibrahim Tekdemir, Etem Beskonakli, Haluk Deda.   

Abstract

OBJECT: Placement of pedicle screws into S-1 is difficult. In cases in which there is a closed posterior superior iliac spine (PSIS), its medial situation prevents lateral oblique placement of the screw inserter sleeve and directing the screw to the anteromedial aspect of S-1. In the present study, the authors discuss anatomical variations of the PSIS and sacrum, and they describe a safe and effective S-1 screw insertion technique.
METHODS: The relation of 50 PSISs obtained from 25 dry pelvises (15 male and 10 female cadavers) was examined. The distance from the inferolateral aspect of the S-1 superior articular facet to its promontory was estimated. The relation between the point of anterior penetration of the "screw line" and "safe zone" was analyzed. Penetration of screw lines into the S-1 body was also measured. (An illustrative case of closed PSIS is presented with pre- and postoperative computerized tomography [CT] scan findings.) The authors found that that PSIS was situated in 28% of the specimens. When screws were directed anteromedially, the screw lines failed to penetrate the S-1 body in 24% of the male and in 15% of female specimens. The screw lines deviated from the safe zone anteriorly in 34% of the male and in 20% of the female specimens. When the PSIS was medial to the line that connects the inferolateral aspect of the S-1 superior articular facet to the promontory, a classification of closed PSIS was assigned.
CONCLUSIONS: The accuracy of the placement of the screws and their pullout strength are increased when using the present technique. Preoperative CT scanning should be performed to determine the presence of a closed PSIS; in cases in which a closed PSIS is found, the ilium should be resected to enable a greater anteromedial trajectory for placement of S-1 pedicle screws.

Mesh:

Year:  2003        PMID: 12956467     DOI: 10.3171/spi.2003.99.2.0229

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  8 in total

1.  A study of sacral anthropometry to determine S1 screw placement for spinal lumbosacral fixation in the Korean population.

Authors:  Young-Yul Kim; Kee-Yong Ha; Sang-Il Kim; In-Soo Oh
Journal:  Eur Spine J       Date:  2015-07-31       Impact factor: 3.134

2.  Morphometry of the sacrum for clinical use.

Authors:  H Başaloğlu; M Turgut; F A Taşer; T Ceylan; H K Başaloğlu; A A Ceylan
Journal:  Surg Radiol Anat       Date:  2005-10-07       Impact factor: 1.246

3.  Neurovascular risks of sacral screws with bicortical purchase: an anatomical study.

Authors:  Ipek Ergur; Omer Akcali; Amac Kiray; Can Kosay; Hamid Tayefi
Journal:  Eur Spine J       Date:  2007-02-14       Impact factor: 3.134

4.  [Submuscular approach to the lumbar spine and extraforaminal cage implantation].

Authors:  F Magerl
Journal:  Orthopade       Date:  2011-02       Impact factor: 1.087

5.  The sacral screw placement depending on morphological and anatomical peculiarities.

Authors:  Carolin Meyer; Peter Pfannebecker; Jan Siewe; David Grevenstein; Jan Bredow; Peer Eysel; Max Joseph Scheyerer
Journal:  Surg Radiol Anat       Date:  2019-11-23       Impact factor: 1.246

6.  L5 nerve root injury caused by anterolateral malpositioning of loosened S1 pedicle screws: illustrative cases.

Authors:  Shota Tamagawa; Takatoshi Okuda; Hidetoshi Nojiri; Rei Momomura; Muneaki Ishijima
Journal:  J Neurosurg Case Lessons       Date:  2021-06-21

7.  Can intermuscular cleavage planes provide proper transverse screw angle? Comparison of two paraspinal approaches.

Authors:  Xiaofei Cheng; Bin Ni; Qi Liu; Jinshui Chen; Huapeng Guan
Journal:  Eur Spine J       Date:  2012-08-11       Impact factor: 3.134

8.  L5 spinal nerve injury caused by misplacement of outwardly-inserted S1 pedicle screws.

Authors:  Masahiro Inoue; Gen Inoue; Tomoyuki Ozawa; Masayuki Miyagi; Hiroto Kamoda; Tetsuhiro Ishikawa; Miyako Suzuki; Yoshihiro Sakuma; Yasuhiro Oikawa; Kazuyo Yamauchi; Sumihisa Orita; Masashi Takaso; Tomoaki Toyone; Kazuhisa Takahashi; Seiji Ohtori
Journal:  Eur Spine J       Date:  2012-12-28       Impact factor: 3.134

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.