Efficacy of implantable loop recorders in establishing symptom-rhythm correlation in young patients with syncope and palpitations.

Joseph Rossano1, Beatrijs Bloemers, Narayanswami Sreeram, Seshadri Balaji, Maully J Shah.   

Abstract

OBJECTIVE: To evaluate efficacy of the recently introduced implantable loop recorder (ILR) in establishing symptom-rhythm correlation in young patients with syncope, near syncope, palpitations, and acute life-threatening events (ALTEs).
METHODS: A retrospective study was conducted with patients with ILR from 3 pediatric centers. Inclusion criteria were age <or=25 years and a minimum follow-up of 1 month. All ILR-stored events were analyzed regularly for the presence or absence of an arrhythmia at the time of the symptomatic event.
RESULTS: Twenty-one patients (12 male, 9 female) with an average age of 12.3 +/- 5.3 years (range: 0.8-22 years) were included in the study. Five (24%) patients had structural heart disease, 2 (10%) had a family history of sudden cardiac death, 3 (14%) had QT prolongation on electrocardiogram, and 11 had no cardiovascular disease. Indications for ILR were recurrent syncope and near syncope (n = 15), palpitations (n = 2), and ALTE (n = 2). Fourteen (67%) patients continued to have symptoms, and 7 (33%) had no symptoms after ILR over a follow-up period of 8.4 +/- 4.7 months (range: 1.9-16 months). Symptom-rhythm correlation was possible in all 14 patients who continued to have symptoms (supraventricular tachycardia in 4, ventricular tachycardia in 2, torsades de points in 1, asystole in 1, junctional bradycardia in 1, and sinus rhythm in 5).
CONCLUSIONS: ILR is useful in determining the presence or absence of an arrhythmia during symptoms of syncope, near syncope, and palpitations as well as ALTEs in patients with and without structural heart disease when conventional diagnostic testing, such as electrocardiogram, Holter monitoring, and/or external loop recording, is inconclusive.

Entities:  

Mesh:

Year:  2003        PMID: 12949317     DOI: 10.1542/peds.112.3.e228

Source DB:  PubMed          Journal:  Pediatrics        ISSN: 0031-4005            Impact factor:   7.124


  12 in total

Review 1.  Pediatric Disorders of Orthostatic Intolerance.

Authors:  Julian M Stewart; Jeffrey R Boris; Gisela Chelimsky; Phillip R Fischer; John E Fortunato; Blair P Grubb; Geoffrey L Heyer; Imad T Jarjour; Marvin S Medow; Mohammed T Numan; Paolo T Pianosi; Wolfgang Singer; Sally Tarbell; Thomas C Chelimsky
Journal:  Pediatrics       Date:  2017-12-08       Impact factor: 7.124

2.  PocketECG: A New Noninvasive Method for Continuous and Real-Time ECG Monitoring-Initial Results in Children and Adolescents.

Authors:  Katarzyna Bieganowska; Agnieszka Kaszuba; Maciej Bieganowski; Krzysztof Kaczmarek
Journal:  Pediatr Cardiol       Date:  2017-01-18       Impact factor: 1.655

3.  Arrhythmia Detection in Pediatric Patients: ECG Quality and Diagnostic Yield of a Patient-Triggered Einthoven Lead-I Event Recorder (Zenicor EKG-2™).

Authors:  Lea Usadel; Guido Haverkämper; Susanne Herrmann; Rebekka Löber; Katja Weiss; Bernd Opgen-Rhein; Felix Berger; Joachim C Will
Journal:  Pediatr Cardiol       Date:  2015-11-14       Impact factor: 1.655

4.  The diagnostic yield from implantable loop recorders in children and young adults.

Authors:  N Sreeram; M Gass; C Apitz; G Ziemer; M Hofbeck; M Emmel; K Brockmeier; F Hitchcock; G Bennink
Journal:  Clin Res Cardiol       Date:  2007-12-24       Impact factor: 5.460

5.  Holter Monitoring and Loop Recorders: From Research to Clinical Practice.

Authors:  Alessio Galli; Francesco Ambrosini; Federico Lombardi
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-08

6.  Using a Cardiac Event Recorder in Children with Potentially Arrhythmia-Related Symptoms.

Authors:  Murat Saygi; Yakup Ergul; Isa Ozyilmaz; Fatma Sevinc Sengul; Osman Guvenc; Eyup Aslan; Alper Guzeltas; Celal Akdeniz; Volkan Tuzcu
Journal:  Ann Noninvasive Electrocardiol       Date:  2016-01-21       Impact factor: 1.468

7.  Idiopathic ventricular arrhythmias detected by an implantable loop recorder in a child with exercise-induced syncope.

Authors:  Celal Akdeniz; Isa Ozyilmaz; Murat Saygi; Yakup Ergul; Volkan Tuzcu
Journal:  Tex Heart Inst J       Date:  2013

8.  Catecholaminergic polymorphic ventricular tachycardia detected by an insertable loop recorder in a pediatric patient with exercise syncopal episodes.

Authors:  J M Ormaetxe; R Sáez; M F Arkotxa; J D Martinez-Alday
Journal:  Pediatr Cardiol       Date:  2004 Nov-Dec       Impact factor: 1.655

Review 9.  Common syndromes of orthostatic intolerance.

Authors:  Julian M Stewart
Journal:  Pediatrics       Date:  2013-04-08       Impact factor: 7.124

10.  2021 PACES expert consensus statement on the indications and management of cardiovascular implantable electronic devices in pediatric patients.

Authors:  Maully J Shah; Michael J Silka; Jennifer N Avari Silva; Seshadri Balaji; Cheyenne M Beach; Monica N Benjamin; Charles I Berul; Bryan Cannon; Frank Cecchin; Mitchell I Cohen; Aarti S Dalal; Brynn E Dechert; Anne Foster; Roman Gebauer; M Cecilia Gonzalez Corcia; Prince J Kannankeril; Peter P Karpawich; Jeffery J Kim; Mani Ram Krishna; Peter Kubuš; Martin J LaPage; Douglas Y Mah; Lindsey Malloy-Walton; Aya Miyazaki; Kara S Motonaga; Mary C Niu; Melissa Olen; Thomas Paul; Eric Rosenthal; Elizabeth V Saarel; Massimo Stefano Silvetti; Elizabeth A Stephenson; Reina B Tan; John Triedman; Nicholas H Von Bergen; Philip L Wackel
Journal:  Indian Pacing Electrophysiol J       Date:  2021-07-29