Fatigue resistance of cast occlusal rests using Co-Cr and Ag-Pd-Cu-Au alloys.

Cynthia G Gapido1, Hiroshi Kobayashi, Osamu Miyakawa, Shoji Kohno.   

Abstract

STATEMENT OF PROBLEM: Fatigue failure in a removable partial denture framework includes fracture of the occlusal rest at the rest-minor connector angle.
PURPOSE: This in vitro study evaluated the fatigue resistance of 0.8-mm-thick occlusal rests cast with Co-Cr and Ag-Pd-Cu-Au alloys.
MATERIAL AND METHODS: The specimen consisted of occlusal rest (0.8 x 2.0 x 10 mm), vertical minor connector (0.9 x 2.0 x 5.0 mm), and denture base connector (1.5 x 5.0 x 25 mm). Twenty-five specimens each were cast with Co-Cr and Ag-Pd-Cu-Au alloys. From each group, 5 specimens were subjected to a load-deflection test conducted to determine the amount of deflection to be used in fatigue test. The fatigue test was performed such that the occlusal rest component was deflected by displacing the denture base component in a tissueward direction. Predetermined denture base displacement values of 0.25 and 0.49 mm for Co-Cr and Ag-Pd-Cu-Au specimens, respectively, were repeated at a rate of 500 cycles/min by use of a displacement-controlled fatigue testing machine, until occlusal rest failure occurred or a preset limit of 2 million cycles was achieved. The survival rates of the occlusal rests were calculated assuming a chewing cycle of 2 x 10(5) per year. Scanning electron microscopy (SEM) photographs were made to examine the fracture surfaces and to identify casting defects. The relationship between fatigue cycles and number of casting defects was determined by Spearman rank correlation analysis (P<.01).
RESULTS: All 20 Co-Cr specimens outran the preset limit, whereas 18 Ag-Pd-Cu-Au specimens fractured. After 3 years of simulated clinical use, only 50% of the Ag-Pd-Cu-Au occlusal rests survived. Statistical analysis showed that the fatigue cycles and number of casting defects were inversely related (P<.01). Fatigue crack initiation occurred at the inner-curvature surface of the rest-minor connector angle. The typical Ag-Pd-Cu Au fatigue fracture surface consisted of smooth propagation and dimpled and smooth final fracture areas.
CONCLUSIONS: This study suggests that cast Co-Cr rests are more rigid and fatigue resistant than Ag-Pd-Cu-Au rests. The fatigue resistance of 0.8-mm-thick occlusal rests may be adequate if cast with Co-Cr alloy. An increased number of casting defects may hasten the fatigue failure of occlusal rests.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12942060     DOI: 10.1016/s0022-3913(03)00367-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Effects of conventional welding and laser welding on the tensile strength, ultimate tensile strength and surface characteristics of two cobalt-chromium alloys: a comparative study.

Authors:  Seenivasan Madhan Kumar; Jayesh Raghavendra Sethumadhava; Vaidyanathan Anand Kumar; Grover Manita
Journal:  J Indian Prosthodont Soc       Date:  2012-04-18

2.  Fatigue lifetime prediction of a reduced-diameter dental implant system: Numerical and experimental study.

Authors:  Yuanyuan Duan; Jorge A Gonzalez; Pratim A Kulkarni; William W Nagy; Jason A Griggs
Journal:  Dent Mater       Date:  2018-06-18       Impact factor: 5.304

3.  Comparative Study Clarifying the Most Suitable Material to Be Used as Partial Denture Clasps.

Authors:  Sherif Aly Sadek; Wessam Mohamed Dehis; Hala Hassan
Journal:  Open Access Maced J Med Sci       Date:  2018-06-07

4.  Strain Distribution in a Kennedy Class I Implant Assisted Removable Partial Denture under Various Loading Conditions.

Authors:  Reza Shahmiri; John M Aarts; Vincent Bennani; Raj Das; Michael V Swain
Journal:  Int J Dent       Date:  2013-04-30

5.  Analyse the effect of different investment techniques and pattern materials on surface roughness of raw Ni-Cr castings - An In Vitro study.

Authors:  Aditi Aneesh Kanitkar; Aneesh Shriram Kanitkar; Rutuparna S Sasane; Seema S Patil; Swapnil R Chopade; Seema Vaidya
Journal:  J Indian Prosthodont Soc       Date:  2020-01-27

6.  Examination of inter-rater and intra-rater reliability during retentive force measurement of different clasps using the developed small-sized retentive force measurement device.

Authors:  Hitoshi Akiyama; Maiko Sakamoto; Ryoichi Akama; Jun Takei
Journal:  BMC Oral Health       Date:  2020-08-20       Impact factor: 2.757

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.