Literature DB >> 12939781

A global sensitivity analysis of performance of a medical diagnostic test when verification bias is present.

Andrzej S Kosinski1, Huiman X Barnhart.   

Abstract

Current advances in technology provide less invasive or less expensive diagnostic tests for identifying disease status. When a diagnostic test is evaluated against an invasive or expensive gold standard test, one often finds that not all patients undergo the gold standard test. The sensitivity and specificity estimates based only on the patients with verified disease are often biased. This bias is called verification bias. Many authors have examined the consequences of verification bias and have proposed bias correction methods based on the assumption of independence between disease status and election for verification conditionally on the test result, or equivalently on the assumption that the disease status is missing at random using missing data terminology. This assumption may not be valid and one may need to consider adjustment for a possible non-ignorable verification bias resulting from the non-ignorable missing data mechanism. Such an adjustment involves ultimately uncheckable assumptions and requires sensitivity analysis. The sensitivity analysis is most often accomplished by perturbing parameters in the chosen model for the missing data mechanism, and it has a local flavour because perturbations are around the fitted model. In this paper we propose a global sensitivity analysis for assessing performance of a diagnostic test in the presence of verification bias. We derive a region of all sensitivity and specificity values consistent with the observed data and call this region a test ignorance region (TIR). The term 'ignorance' refers to the lack of knowledge due to the missing disease status for the not verified patients. The methodology is illustrated with two clinical examples. Copyright 2003 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2003        PMID: 12939781     DOI: 10.1002/sim.1517

Source DB:  PubMed          Journal:  Stat Med        ISSN: 0277-6715            Impact factor:   2.373


  10 in total

1.  Comparison of three commercial immunoassays for detection of herpes simplex virus type 2 antibodies in commercial sex workers in Yunnan Province, China.

Authors:  Thoai D Ngo; Oliver Laeyendecker; Rhoda Ashley Morrow; Shenghan Lai; Thomas C Quinn
Journal:  Clin Vaccine Immunol       Date:  2008-05-28

2.  Clinical usefulness of pit patterns for detecting colonic lesions requiring surgical treatment.

Authors:  Yasutoshi Kobayashi; Shin-Ei Kudo; Hideyuki Miyachi; Toshihisa Hosoya; Nobunao Ikehara; Kazuo Ohtsuka; Hiroshi Kashida; Shigeharu Hamatani; Shiro Hinotsu; Koji Kawakami
Journal:  Int J Colorectal Dis       Date:  2011-05-24       Impact factor: 2.571

3.  Diagnostic accuracy of immunochemical versus guaiac faecal occult blood tests for colorectal cancer screening.

Authors:  Adolfo Parra-Blanco; Antonio Z Gimeno-García; Enrique Quintero; David Nicolás; Santiago G Moreno; Alejandro Jiménez; Manuel Hernández-Guerra; Marta Carrillo-Palau; Yoshinobu Eishi; Julio López-Bastida
Journal:  J Gastroenterol       Date:  2010-02-17       Impact factor: 7.527

4.  Effect of sexually transmitted disease (STD) coinfections on performance of three commercially available immunosorbent assays used for detection of herpes simplex virus type 2-specific antibody in men attending Baltimore, Maryland, STD clinics.

Authors:  Jean Summerton; Melissa Riedesel; Oliver Laeyendecker; Charlotte Gaydos; Nancy E Maldeis; Andrew Hardick; Rhoda Ashley Morrow; Thomas C Quinn
Journal:  Clin Vaccine Immunol       Date:  2007-10-03

5.  PROspective Multicenter Imaging Study for Evaluation of chest pain: rationale and design of the PROMISE trial.

Authors:  Pamela S Douglas; Udo Hoffmann; Kerry L Lee; Daniel B Mark; Hussein R Al-Khalidi; Kevin Anstrom; Rowena J Dolor; Andrzej Kosinski; Mitchell W Krucoff; Daniel W Mudrick; Manesh R Patel; Michael H Picard; James E Udelson; Eric J Velazquez; Lawton Cooper
Journal:  Am Heart J       Date:  2014-03-18       Impact factor: 4.749

Review 6.  Estimation of diagnostic test accuracy without full verification: a review of latent class methods.

Authors:  John Collins; Minh Huynh
Journal:  Stat Med       Date:  2014-06-09       Impact factor: 2.373

7.  Uterine cavity assessment in infertile women: Sensitivity and specificity of three-dimensional Hysterosonography versus Hysteroscopy.

Authors:  Firoozeh Ahmadi; Zohreh Rashidy; Hadieh Haghighi; Mohamadreza Akhoond; Maryam Niknejadi; Mandana Hemat; Mansour Shamsipour
Journal:  Iran J Reprod Med       Date:  2013-12

8.  Anticipating missing reference standard data when planning diagnostic accuracy studies.

Authors:  Christiana A Naaktgeboren; Joris A H de Groot; Anne W S Rutjes; Patrick M M Bossuyt; Johannes B Reitsma; Karel G M Moons
Journal:  BMJ       Date:  2016-02-09

9.  Accuracy of Two-Dimensional Transvaginal Sonography and Office Hysteroscopy for Detection of Uterine Abnormalities in Patients with Repeated Implantation Failures or Recurrent Pregnancy Loss.

Authors:  Marzieh Shiva; Firouzeh Ahmadi; Arezoo Arabipoor; Mansoureh Oromiehchi; Mohammad Chehrazi
Journal:  Int J Fertil Steril       Date:  2017-10-12

10.  Diagnostic test evaluation methodology: A systematic review of methods employed to evaluate diagnostic tests in the absence of gold standard - An update.

Authors:  Chinyereugo M Umemneku Chikere; Kevin Wilson; Sara Graziadio; Luke Vale; A Joy Allen
Journal:  PLoS One       Date:  2019-10-11       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.