Literature DB >> 12939339

Frequency-doubling technology perimetry and optical defocus.

Andrew John Anderson1, Chris A Johnson.   

Abstract

PURPOSE: The frequency-doubling technology (FDT) perimeter has no provision for introducing corrective lenses, save for the patient's spectacles, and so patients are sometimes tested in the presence of moderate levels of defocus. The effect of defocus on frequency-doubling (FD) sensitivity was determined for both the commercially available instrument and for smaller targets that may be useful in spatially localizing visual field defects. In addition, whether stimulus artifacts may be detectable in the presence of defocus was assessed.
METHODS: Detection and resolution thresholds for FD stimuli, along with detection thresholds for spatially uniform flickering stimuli, were measured in normal observers in the presence of up to +6 D of defocus. In addition, the effect of defocus on the summary indices (mean deviation [MD], and pattern standard deviation [PSD]) of both the commercial FDT perimeter and a customized perimeter with smaller, higher spatial frequency targets was determined.
RESULTS: Thresholds for conventional FD targets (0.25 cyc/deg, 25 Hz) increased 0.1 log unit with +6 D defocus, whereas thresholds for smaller, higher spatial frequency (0.5 cyc/deg) targets increased 0.4 log unit. Despite the presence of a luminance artifact in the FD stimuli, detection, and resolution thresholds remained coincident at maximum defocus, suggesting that the artifact was not detectable. MD was significantly affected by defocus for the customized FD perimeter only, and PSD was not altered for either the conventional or customized test.
CONCLUSIONS: In normal observers, optical defocus has little effect on FDT perimetry sensitivity and does not make low spatial frequency artifacts detectable. Improving the spatial resolution of FDT perimetry decreases its robustness to defocus.

Entities:  

Mesh:

Year:  2003        PMID: 12939339     DOI: 10.1167/iovs.02-1076

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  9 in total

1.  Assessing spatial and temporal properties of perimetric stimuli for resistance to clinical variations in retinal illumination.

Authors:  William H Swanson; Mitchell W Dul; Douglas G Horner; Tiffany Liu; Irene Tran
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-01-20       Impact factor: 4.799

Review 2.  Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma.

Authors:  M A R Siddiqui; A Azuara-Blanco; S Neville
Journal:  Br J Ophthalmol       Date:  2005-12       Impact factor: 4.638

3.  Combining Frequency Doubling Technology Perimetry and Scanning Laser Polarimetry for Glaucoma Detection.

Authors:  Jean-Claude Mwanza; Joshua L Warren; Jessica T Hochberg; Donald L Budenz; Robert T Chang; Pradeep Y Ramulu
Journal:  J Glaucoma       Date:  2015 Oct-Nov       Impact factor: 2.503

4.  Blur-resistant perimetric stimuli.

Authors:  Douglas G Horner; Mitchell W Dul; William H Swanson; Tiffany Liu; Irene Tran
Journal:  Optom Vis Sci       Date:  2013-05       Impact factor: 1.973

5.  Frequency doubling technology threshold visual field results vary with software version.

Authors:  Nagisa Kojima; Shiroaki Shirato; Yuko Ohno
Journal:  Jpn J Ophthalmol       Date:  2007-12-21       Impact factor: 2.447

6.  Individual differences in the shape of the nasal visual field.

Authors:  William H Swanson; Mitchell W Dul; Douglas G Horner; Victor E Malinovsky
Journal:  Vision Res       Date:  2016-06-16       Impact factor: 1.886

Review 7.  [Frequency-doubling technology : A new method for determining glaucomatous visual field defects].

Authors:  J Lamparter; A Schulze; E M Hoffmann
Journal:  Ophthalmologe       Date:  2009-08       Impact factor: 1.059

Review 8.  Prevalence of glaucoma in rural Myanmar: the Meiktila Eye Study.

Authors:  R J Casson; H S Newland; J Muecke; S McGovern; L Abraham; W K Shein; D Selva; T Aung
Journal:  Br J Ophthalmol       Date:  2007-06       Impact factor: 4.638

9.  Prevalence and characteristics of glaucoma among Korean adults.

Authors:  Ji Hyun Kim; Sung Yong Kang; Na Rae Kim; Eun Suk Lee; Samin Hong; Gong Je Seong; Young Jae Hong; Chan Yun Kim
Journal:  Korean J Ophthalmol       Date:  2011-03-11
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.