Literature DB >> 12938848

Laboratory evaluation of a self-etching primer for orthodontic bonding.

Y D Aljubouri1, D T Millett, W H Gilmour.   

Abstract

The aim of the present study was to compare the mean bonding time, mean shear bond strength and mean survival time of stainless steel brackets with a micro-etched base bonded with a light-cure composite using a self-etching primer (SEP) or a conventional two-stage etch and prime system. Brackets were bonded to 30 premolars with each bonding system. The bonding time was recorded for each specimen using a stopwatch. After storage in a humidor at 37 degrees C for 24 hours, the shear debonding force was measured at a crosshead speed of 0.5 mm/minute. Another 10 premolars were bonded with each bonding system and used to assess survival time following the application of mechanical stress in a ball mill for 100 hours. The mean bonding time of the SEP group (111.5 seconds) was significantly less than that of the two-stage bonding group (170.5 seconds) [mean difference 59 seconds; 95 per cent confidence interval (CI) 51.8-66.2 seconds, two sample t-test P < 0.001]. The mean shear bond strength of the SEP group (2.88 MPa) was significantly less than that of the two-stage bonding group (3.71 MPa) (mean difference 0.83 MPa; 95 per cent CI 0.23-1.42 MPa; two sample t-test P = 0.008). For the survival study, only one of the two-stage bonding group failed within 1 hour in the ball mill. The SEP significantly reduced bracket bonding time. The mean shear bond strength of the brackets bonded with the SEP was significantly less than those bonded with a conventional two-stage etch and prime system. There was no difference in survival time of brackets bonded by each bonding system.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12938848     DOI: 10.1093/ejo/25.4.411

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  12 in total

1.  Optimal enamel conditioning strategy for rebonding orthodontic brackets: a laboratory study.

Authors:  Qi-Feng Zhang; Hua Yao; Zhi-Yong Li; Li Jin; Hui-Ming Wang
Journal:  Int J Clin Exp Med       Date:  2014-09-15

2.  Clinical performance of precoated brackets and self-etch bonding technique: a prospective comparative study.

Authors:  Ezgi Atik; Hande Gorucu-Coskuner; Tulin Taner
Journal:  Clin Oral Investig       Date:  2018-11-30       Impact factor: 3.573

3.  Effects of Different Combinations of Er:YAG Laser-Adhesives on Enamel Demineralization and Bracket Bond Strength.

Authors:  Serpil Çokakoğlu; Ruhi Nalçacı; Serdar Üşümez; Sıddık Malkoç
Journal:  Photomed Laser Surg       Date:  2016-03-17       Impact factor: 2.796

4.  Comparison of Self-Etch Primers with Conventional Acid Etching System on Orthodontic Brackets.

Authors:  Amit Zope; Yogita Zope-Khalekar; Shrikant S Chitko; Veerendra V Kerudi; Harshal Ashok Patil; Prasad Vasudeo Bonde; Pratik Jaltare; Siddhesh G Dolas
Journal:  J Clin Diagn Res       Date:  2016-12-01

5.  Effects of procedures of remineralization around orthodontics bracket bonded by self-etching primer on its shear bond strength.

Authors:  Mahmoud Al-Suleiman; Nick Silikas; David Watts
Journal:  J Orthod Sci       Date:  2012-07

6.  Shear bond strength and debonding characteristics of metal and ceramic brackets bonded with conventional acid-etch and self-etch primer systems: An in-vivo study.

Authors:  Behnam Mirzakouchaki; Sajjad Shirazi; Reza Sharghi; Samaneh Shirazi; Mahsan Moghimi; Shirin Shahrbaf
Journal:  J Clin Exp Dent       Date:  2016-02-01

7.  Effect of Intracanal Post Space Treatments on Push-Out Bond Strength of Fiber Posts to Root Dentin.

Authors:  Hamid Kermanshah; Behnam Bolhari; Faraz Sedaghat; Ladan Ranjbar Omrani
Journal:  J Dent (Tehran)       Date:  2017-01

8.  Comparison of shear bond strength and enamel surface changing between the two-step etching and primer and self-etch primer methods in rebonding of orthodontic brackets: An in vitro study.

Authors:  Shiva Alavi; Ailin Ehteshami
Journal:  Dent Res J (Isfahan)       Date:  2019 Jul-Aug

9.  Clinical bond failure rates of adhesive precoated self-ligating brackets using a self-etching primer.

Authors:  Mete Ozer; Mehmet Bayram; Cagri Dincyurek; Fuat Tokalak
Journal:  Angle Orthod       Date:  2013-07-02       Impact factor: 2.079

10.  Effect of clearfil protect bond and transbond plus self-etch primer on shear bond strength of orthodontic brackets.

Authors:  S Hamid Raji; Reza Ghorbanipour; Fateme Majdzade
Journal:  Dent Res J (Isfahan)       Date:  2011-12
View more