Literature DB >> 26987047

Effects of Different Combinations of Er:YAG Laser-Adhesives on Enamel Demineralization and Bracket Bond Strength.

Serpil Çokakoğlu1, Ruhi Nalçacı2, Serdar Üşümez3, Sıddık Malkoç4.   

Abstract

OBJECTIVE: The purpose of this study was to investigate the demineralization around brackets and shear bond strength (SBS) of brackets bonded to Er:YAG laser-irradiated enamel at different power settings with various adhesive systems combinations.
METHODS: A total of 108 premolar teeth were used in this study. Teeth were assigned into three groups according to the etching procedure, then each group divided into three subgroups based on the application of different adhesive systems. There were a total of nine groups as follows. Group 1: Acid + Transbond XT Primer; group 2: Er:YAG (100 mJ, 10 Hz) etching + Transbond XT Primer; group 3: Er:YAG (200 mJ, 10 Hz) etching + Transbond XT Primer; group 4: Transbond Plus self-etching primer (SEP); group 5: Er:YAG (100 mJ, 10 Hz) etching + Transbond Plus SEP; group 6: Er:YAG (200 mJ, 10 Hz) etching + Transbond Plus SEP; group 7: Clearfil Protect Bond; group 8: Er:YAG (100 mJ, 10 Hz) etching + Clearfil Protect Bond; group 9: Er:YAG (200 mJ, 10 Hz) etching + Clearfil Protect Bond. Brackets were bonded with Transbond XT Adhesive Paste in all groups. Teeth to be evaluated for demineralization and SBS were exposed to pH and thermal cyclings, respectively. Then, demineralization samples were scanned with micro-CT to determine lesion depth values. For SBS test, a universal testing machine was used and adhesive remnant was index scored after debonding. Data were analyzed statistically.
RESULTS: No significant differences were found among the lesion depth values of the various groups, except for G7 and G8, in which the lowest values were recorded. The lowest SBS values were in G7, whereas the highest were in G9. The differences between the other groups were not significant.
CONCLUSIONS: Er:YAG laser did not have a positive effect on prevention of enamel demineralization. When two step self-etch adhesive is preferred for bonding brackets, laser etching at 1 W (100 mJ, 10 Hz) is suggested to improve SBS of brackets.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26987047      PMCID: PMC4827284          DOI: 10.1089/pho.2015.4041

Source DB:  PubMed          Journal:  Photomed Laser Surg        ISSN: 1549-5418            Impact factor:   2.796


  30 in total

1.  Shear bond strength of orthodontic brackets with newly developed antibacterial self-etch adhesive.

Authors:  Neslihan Eminkahyagil; Yonca Korkmaz; Saadet Gokalp; Meserret Baseren
Journal:  Angle Orthod       Date:  2005-09       Impact factor: 2.079

2.  Effect of self-etching primer and adhesive formulations on the shear bond strength of orthodontic brackets.

Authors:  Zafer C Cehreli; Defne Kecik; Ilken Kocadereli
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-05       Impact factor: 2.650

3.  Optimal Er:YAG laser energy for preventing enamel demineralization.

Authors:  Jeng-Fen Liu; Yuanyuan Liu; Hsu Chin-Ying Stephen
Journal:  J Dent       Date:  2005-06-06       Impact factor: 4.379

4.  Shear bond strength of orthodontic brackets with 3 self-etch adhesives.

Authors:  Neslihan Arhun; Ayça Arman; Cagla Sesen; Erdem Karabulut; Yonca Korkmaz; Saadet Gokalp
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-04       Impact factor: 2.650

5.  Comparison of shear bond strength of two self-etch primer/adhesive systems.

Authors:  Samir E Bishara; Raed Ajlouni; John F Laffoon; John J Warren
Journal:  Angle Orthod       Date:  2006-01       Impact factor: 2.079

6.  Bracket bond strengths of new adhesive systems.

Authors:  Gerald T Minick; Larry J Oesterle; Sheldon M Newman; William Craig Shellhart
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-06       Impact factor: 2.650

7.  A possible mechanism of acquired acid resistance of human dental enamel by laser irradiation.

Authors:  T Oho; T Morioka
Journal:  Caries Res       Date:  1990       Impact factor: 4.056

8.  Subablative Er:YAG laser effect on enamel demineralization.

Authors:  Y Liu; C-Y S Hsu; C M J Teo; S H Teoh
Journal:  Caries Res       Date:  2012-10-30       Impact factor: 4.056

9.  Acid resistance of erbium-doped yttrium aluminum garnet laser-treated and phosphoric acid-etched enamels.

Authors:  Jung-Ho Kim; Oh-Won Kwon; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Angle Orthod       Date:  2006-11       Impact factor: 2.079

10.  Bond strengths of an antibacterial monomer-containing adhesive system applied with and without acid etching for lingual retainer bonding.

Authors:  Mustafa Ulker; Tancan Uysal; Sabri Ilhan Ramoglu; Faruk Izzet Ucar
Journal:  Eur J Orthod       Date:  2009-06-01       Impact factor: 3.075

View more
  2 in total

1.  Effect of Erbium, Chromium-Doped: Yttrium, Scandium, Gallium, and Garnet and Erbium: Yttrium-Aluminum-Garnet Laser Etching on Enamel Demineralization and Shear Bond Strength of Orthodontic Brackets.

Authors:  Vahid Mollabashi; Loghman Rezaei-Soufi; Maryam Farhadian; Ali Reza Noorani
Journal:  Contemp Clin Dent       Date:  2019 Apr-Jun

Review 2.  The Use of Laser Energy for Etching Enamel Surfaces in Dentistry-A Scoping Review.

Authors:  Anca Labunet; Andrada Tonea; Andreea Kui; Sorina Sava
Journal:  Materials (Basel)       Date:  2022-03-08       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.