Literature DB >> 12927458

Microtensile bond strength of total-etch and self-etching adhesives to caries-affected dentine.

Laura Ceballos1, Defrén G Camejo, M Victoria Fuentes, Raquel Osorio, Manuel Toledano, Ricardo M Carvalho, David H Pashley.   

Abstract

OBJECTIVES: To evaluate the microtensile bond strength of total-etch or self-etch adhesives to caries-affected versus normal dentine, and to correlate these bond strengths with DIAGNOdent laser fluorescence and Knoop microhardness (KH) measurements of the substrates.
METHODS: Extracted carious human molars were ground to expose flat surfaces where the caries lesion was surrounded by normal dentine. Surfaces were bonded with either Prime & Bond NT, Scotchbond 1, Clearfil SE Bond or Prompt L-Pop, according to manufacturers' recommendations. A crown was built up using resin composite (Tetric Ceram). After storage in water (37 degrees C, 24 h), teeth were vertically serially sectioned into 0.7 mm thick slabs and trimmed to yield 1 mm(2) test area that contained either caries-affected or normal dentine. Samples were tested in tension in an Instron machine at 1 mm/min. The quality of the dentine just beneath each fractured specimen was measured by laser fluorescence and KH.
RESULTS: Total-etch adhesives yielded higher bond strengths than self-etching systems. Significantly lower results were obtained with Prompt L-Pop. All the adhesives attained higher strengths in normal than in caries-affected dentine, but the differences were only significant for Prime &amp; Bond NT and Clearfil SE Bond. Higher laser fluorescence values and lower KH (p<0.001) were recorded in caries-affected dentine compared to normal dentine.
CONCLUSIONS: The total-etch adhesives evaluated produced higher bond strengths to normal and caries-affected dentine than self-etching systems. Laser fluorescence measurements discriminated caries-affected dentine from normal dentine, and were strongly correlated with KH. However, laser fluorescence and KH did not permit high correlations with resin-dentine bond strengths in caries-affected dentine.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12927458     DOI: 10.1016/s0300-5712(03)00088-5

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  15 in total

1.  Caries detection under composite restorations by laser fluorescence and digital radiography.

Authors:  Suwadee Kositbowornchai; Chotikpanich Sukanya; Tangkittikasem Tidarat; Thongsombat Chanoggarn
Journal:  Clin Oral Investig       Date:  2012-12-16       Impact factor: 3.573

2.  Microtensile bond strength analysis of adhesive systems to Er:YAG and Er,Cr:YSGG laser-treated dentin.

Authors:  Thaysa Monteiro Ramos; Thayanne Monteiro Ramos-Oliveira; Simone Gonçalves Moretto; Patricia Moreira de Freitas; Marcella Esteves-Oliveira; Carlos de Paula Eduardo
Journal:  Lasers Med Sci       Date:  2013-01-26       Impact factor: 3.161

3.  Influence of Er:YAG and Ti:sapphire laser irradiation on the microtensile bond strength of several adhesives to dentin.

Authors:  M Portillo; M C Lorenzo; P Moreno; A García; J Montero; L Ceballos; M V Fuentes; A Albaladejo
Journal:  Lasers Med Sci       Date:  2013-05-16       Impact factor: 3.161

4.  Quantitative analysis of adhesive resin in the hybrid layer using Raman spectroscopy.

Authors:  Yuan Zou; Steven R Armstrong; Julie L P Jessop
Journal:  J Biomed Mater Res A       Date:  2010-07       Impact factor: 4.396

5.  In vitro enzymatic biodegradation of adhesive resin in the hybrid layer.

Authors:  Yuan Zou; Julie L P Jessop; Steven R Armstrong
Journal:  J Biomed Mater Res A       Date:  2010-07       Impact factor: 4.396

6.  Effects of chemical cross-linkers on caries-affected dentin bonding.

Authors:  G V Macedo; M Yamauchi; A K Bedran-Russo
Journal:  J Dent Res       Date:  2009-11-05       Impact factor: 6.116

7.  Effect of 2% chlorhexidine digluconate on the bond strength to normal versus caries-affected dentin.

Authors:  Paula C P Komori; David H Pashley; Leo Tjäderhane; Lorenzo Breschi; Annalisa Mazzoni; Mario Fernando de Goes; Linda Wang; Marcela R Carrilho
Journal:  Oper Dent       Date:  2009 Mar-Apr       Impact factor: 2.440

8.  An in vitro evaluation of shear bond strength of silorane and bis-GMA resin-based composite using different curing units.

Authors:  Manak Khosla; Neeraj Malhotra; Kundabala Mala
Journal:  J Conserv Dent       Date:  2012-07

9.  Morphological evaluation of new total etching and self etching adhesive system interfaces with dentin.

Authors:  Mithra N Hegde; Priyadarshini Hegde; C Ravi Chandra
Journal:  J Conserv Dent       Date:  2012-04

10.  Evaluation of Shear Bond Strength of Newer Bonding Systems on Superficial and Deep Dentin.

Authors:  R Veena Kumari; Kishore Siddaraju; Hema Nagaraj; Ramya Krishna Poluri
Journal:  J Int Oral Health       Date:  2015-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.