Literature DB >> 23677437

Influence of Er:YAG and Ti:sapphire laser irradiation on the microtensile bond strength of several adhesives to dentin.

M Portillo1, M C Lorenzo, P Moreno, A García, J Montero, L Ceballos, M V Fuentes, A Albaladejo.   

Abstract

The aim of the present study was to evaluate the influence of erbium:yttrium-aluminum-garnet (Er:YAG) and Ti:sapphire laser irradiation on the microtensile bond strength (MTBS) of three different adhesive systems to dentin. Flat dentin surfaces from 27 molars were divided into three groups according to laser irradiation: control, Er:YAG (2,940 nm, 100 μs, 2.7 W, 9 Hz) and Ti:sapphire laser (795 nm, 120 fs, 1 W, 1 kHz). Each group was divided into three subgroups according to the adhesive system used: two-step total-etching adhesive (Adper Scotchbond 1 XT, from now on XT), two-step self-etching adhesive (Clearfil SE Bond, from now on CSE), and all-in-one self-etching adhesive (Optibond All-in-One, from now on OAO). After 24 h of water storage, beams of section at 1 mm(2) were longitudinally cut from the samples. Each beam underwent traction test in an Instron machine. Fifteen polished dentin specimens were used for the surface morphology analysis by scanning electron microscopy (SEM). Failure modes of representative debonded microbars were SEM-assessed. Data were analyzed by ANOVA, chi-square test, and multiple linear regression (p < 0.05). In the control group, XT obtained higher MTBS than that of laser groups that performed equally. CSE showed higher MTBS without laser than that with laser groups, where Er:YAG attained higher MTBS than ultrashort laser. When OAO was used, MTBS values were equal in the three treatments. CSE obtained the highest MTBS regardless of the surface treatment applied. The Er:YAG and ultrashort laser irradiation reduce the bonding effectiveness when a two-step total-etching adhesive or a two-step self-etching adhesive are used and do not affect their effectiveness when an all-in-one self-etching adhesive is applied.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23677437     DOI: 10.1007/s10103-013-1343-0

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  34 in total

1.  Regional measurement of resin-dentin bonding as an array.

Authors:  Y Shono; T Ogawa; M Terashita; R M Carvalho; E L Pashley; D H Pashley
Journal:  J Dent Res       Date:  1999-02       Impact factor: 6.116

2.  Bonding to Er-YAG-laser-treated dentin.

Authors:  L Ceballo; M Toledano; R Osorio; F R Tay; G W Marshall
Journal:  J Dent Res       Date:  2002-02       Impact factor: 6.116

3.  Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges.

Authors:  Bart Van Meerbeek; Jan De Munck; Yasuhiro Yoshida; Satoshi Inoue; Marcos Vargas; Padmini Vijay; Kirsten Van Landuyt; Paul Lambrechts; Guido Vanherle
Journal:  Oper Dent       Date:  2003 May-Jun       Impact factor: 2.440

4.  Influence of femtosecond laser treatment on shear bond strength of composite resin bonding to human dentin under simulated pulpal pressure.

Authors:  Susanne Gerhardt-Szep; Kristian Werelius; Francoise de Weerth; Detlef Heidemann; Paul Weigl
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2011-11-18       Impact factor: 3.368

5.  Microtensile bond strength analysis of different adhesive systems and dentin prepared with high-speed and Er:YAG laser: a comparative study.

Authors:  Denise Cerqueira Oliveira; Lussara Azevedo Manhães; Márcia Martins Marques; Adriana Bona Matos
Journal:  Photomed Laser Surg       Date:  2005-04       Impact factor: 2.796

6.  Micro-shear bond strength of Er:YAG-laser-treated dentin.

Authors:  Rubens C R de Carvalho; Patricia M de Freitas; Masayuki Otsuki; Carlos P de Eduardo; Junji Tagami
Journal:  Lasers Med Sci       Date:  2007-05-04       Impact factor: 3.161

7.  Influence of the hydration state on the ultrashort laser ablation of dental hard tissues.

Authors:  Francisco de Assis M G Rego Filho; Maristela Dutra-Corrêa; Gustavo Nicolodelli; Vanderlei S Bagnato; Maria Tereza de Araujo
Journal:  Lasers Med Sci       Date:  2012-05-15       Impact factor: 3.161

8.  Effect of laser irradiation and cavity disinfectant application on the microtensile bond strength of different adhesive systems.

Authors:  Ciğdem Celik; Yonca Ozel; Bora Bağiş; Selim Erkut
Journal:  Photomed Laser Surg       Date:  2010-04       Impact factor: 2.796

9.  Experimental studies of the application of the Er:YAG laser on dental hard substances: I. Measurement of the ablation rate.

Authors:  R Hibst; U Keller
Journal:  Lasers Surg Med       Date:  1989       Impact factor: 4.025

10.  Erbium, chromium:yttrium scandium gallium garnet laser for caries removal: influence on bonding of a self-etching adhesive system.

Authors:  Arlene Tachibana; Márcia Martins Marques; Julia Maria Pavan Soler; Adriana Bona Matos
Journal:  Lasers Med Sci       Date:  2007-10-26       Impact factor: 3.161

View more
  2 in total

1.  Ultrashort pulsed laser conditioning of human enamel: in vitro study of the influence of geometrical processing parameters on shear bond strength of orthodontic brackets.

Authors:  M C Lorenzo; M Portillo; P Moreno; J Montero; A García; S E Santos-del Riego; A Albaladejo
Journal:  Lasers Med Sci       Date:  2013-11-19       Impact factor: 3.161

2.  The effects of Er:YAG, Nd:YAG, and Diode (940nm) Lasers irradiation on Microtensile bond strength of two steps self-etch adhesives.

Authors:  L Resaei-Soufi; K Ghanadan; A Moghimbeigi
Journal:  Laser Ther       Date:  2019-06-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.