OBJECTIVE: This open randomized study examined differences between the effects of an equal dose of salbutamol administered via the Diskus, Turbuhaler, and pMDI plus Volumatic. Measurements included dose response curves, dynamic and static lung volumes, respiratory muscle strength, and systemic effects.
METHODS: The cumulative dose-response study compared the biological effects (pulmonary function, respiratory muscle function, systemic effects) of an equal dose of salbutamol delivered via four different devices in 23 patients with asthma and 21 patients with moderate or severe chronic obstructive pulmonary disease (COPD).
RESULTS: Salbutamol via Volumatic showed significantly better bronchodilation than via pMDI or Turbuhaler in both patient groups. No significant difference was found between salbutamol via Volumatic and Diskus. However, the advantage of Volumatic is of marginal clinical relevance since the additional bronchodilation was a maximum of 140 ml FEV(1) and did not exceed the minimal patient-perceivable improvement. In the asthma group a more evident plasma K(+) decrease was found after salbutamol delivered via pMDI and pMDI plus Volumatic. Furthermore, especially in the COPD patients a significant decrease was observed in hyperinflation and consequently an improvement in maximal inspiratory pressure as a result of salbutamol via all devices.
CONCLUSIONS: Bronchodilation by salbutamol was slightly more effective via Volumatic than via pMDI or Turbuhaler. No significant difference in bronchodilation was found between salbutamol via Volumatic and Diskus. The advantage of Volumatic is not of clinical relevance.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12920494     DOI: 10.1007/s00228-003-0614-2

Source DB:  PubMed          Journal:  Eur J Clin Pharmacol        ISSN: 0031-6970            Impact factor:   2.953


  16 in total

1.  Cumulative and single-dose design to assess the bronchodilator effects of beta2-agonists in individuals with asthma.

Authors:  D Fishwick; L Bradshaw; C Macdonald; R Beasley; D Gash; T Bengtsson; E Bondesson; L Borgström
Journal:  Am J Respir Crit Care Med       Date:  2001-02       Impact factor: 21.405

Review 2.  Consensus Conference on Aerosols and Delivery Devices. September 24-26, 1999, Bermuda.

Authors: 
Journal:  Respir Care       Date:  2000-06       Impact factor: 2.258

3.  Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering beta (2 )agonists bronchodilators in asthma.

Authors:  F S Ram; J Wright; D Brocklebank; J E White
Journal:  BMJ       Date:  2001-10-20

4.  Failure of aminophylline and salbutamol to improve respiratory muscle function and exercise tolerance in healthy humans.

Authors:  B Violante; R Pellegrino; C Vinay; R Selleri; G Ghinamo
Journal:  Respiration       Date:  1989       Impact factor: 3.580

5.  Patient perception of the diskus inhaler: a comparison with the turbuhaler inhaler.

Authors:  M Schlaeppi; K Edwards; R W Fuller; R Sharma
Journal:  Br J Clin Pract       Date:  1996 Jan-Feb

Review 6.  Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease. NHLBI/WHO Global Initiative for Chronic Obstructive Lung Disease (GOLD) Workshop summary.

Authors:  R A Pauwels; A S Buist; P M Calverley; C R Jenkins; S S Hurd
Journal:  Am J Respir Crit Care Med       Date:  2001-04       Impact factor: 21.405

7.  The influence of age, diagnosis, and gender on proper use of metered-dose inhalers.

Authors:  D E Goodman; E Israel; M Rosenberg; R Johnston; S T Weiss; J M Drazen
Journal:  Am J Respir Crit Care Med       Date:  1994-11       Impact factor: 21.405

8.  What are minimal important changes for asthma measures in a clinical trial?

Authors:  N C Santanello; J Zhang; B Seidenberg; T F Reiss; B L Barber
Journal:  Eur Respir J       Date:  1999-07       Impact factor: 16.671

9.  The utility of spirometry in the diagnosis of reversible airways obstruction.

Authors:  H R Smith; C G Irvin; R M Cherniack
Journal:  Chest       Date:  1992-06       Impact factor: 9.410

10.  Effect of salbutamol on dynamic hyperinflation in chronic obstructive pulmonary disease patients.

Authors:  C Tantucci; A Duguet; T Similowski; M Zelter; J P Derenne; J Milic-Emili
Journal:  Eur Respir J       Date:  1998-10       Impact factor: 16.671

View more
  1 in total

1.  Clinical and functional responses to salbutamol inhaled via different devices in asthmatic patients with induced bronchoconstriction.

Authors:  Federico Lavorini; Pietro Geri; Martina Luperini; Nazzarena M Maluccio; Laura Mariani; Cecilia Marmai; Massimo Pistolesi; Giovanni A Fontana
Journal:  Br J Clin Pharmacol       Date:  2004-11       Impact factor: 4.335

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.