Implantation of the VentrAssist Implantable Rotary Blood Pump in sheep.

Natalie L James1, Anita L van der Meer, Glenn A Edwards, Samuel R Snelling, John D Begg, Donald S Esmore, John C Woodard.   

Abstract

The VentrAssist Implantable Rotary Blood Pump (IRBP) is a hydrodynamically suspended, electromagnetically driven, centrifugal blood pump that provides continuous flow of up to 10 L/min at 3,000 rpm. In vivo studies in sheep were conducted to assess system design and performance. Surgery involved thoracotomy with subdiaphragmatic pump placement. Cannulae were transdiaphragmatic, with inflow in the left ventricular apex and outflow anastomosed to the descending aorta. Animals had no anticoagulation or antiplatelet therapy after surgery and no prophylactic antibiotics after recovery. Twelve sheep were supported for 622 pump days. Estimated pump flow ranged from 1 to 5.5 L/min at 1,800 to 2,000 rpm using 2.5 to 4.5 W. There was no clinical evidence of hemolysis or cardiovascular, renal, or hepatic dysfunction. Adverse outcomes included kinking/disconnection of the outflow cannula caused by the graft bend relief (n = 4), which was addressed through cannula redesign. Pump electrical malfunction (n = 4), caused by a silicone potting compound, was corrected using a neutral curing potting material. Surgical/husbandry issues (n = 2) also were addressed. The VentrAssist IRBP provides high flow at low rotational speed and power consumption. Further trials are in progress in advance of in vivo studies of the safety and efficacy of the final system.

Entities:  

Mesh:

Year:  2003        PMID: 12918590

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  4 in total

Review 1.  Mechanical circulatory support devices (MCSD) in Japan: current status and future directions.

Authors:  Setsuo Takatani; Hikaru Matsuda; Akihisa Hanatani; Chisato Nojiri; Kenji Yamazaki; Tadashi Motomura; Katsuhiro Ohuchi; Tohru Sakamoto; Takashi Yamane
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

2.  Flow cytometric assays for quantifying activated ovine platelets.

Authors:  Carl A Johnson; Trevor A Snyder; Joshua R Woolley; William R Wagner
Journal:  Artif Organs       Date:  2007-11-14       Impact factor: 3.094

3.  Noninferiority of Shanghai Cingular biotech's bovine pericardial valve preclinical study in juvenile ovine model.

Authors:  Jin-Miao Chen; Yu Ding; Shu-Yang Lu; Sun Pan; Mieradilijiang Abudupataer; Tao Hong; Chun-Sheng Wang
Journal:  J Thorac Dis       Date:  2016-06       Impact factor: 2.895

4.  Ex Vivo Assessment of a Parabolic-Tip Inflow Cannula for Pediatric Continuous-Flow VADs.

Authors:  Michael T Griffin; Matthew F Grzywinski; Hannah J Voorhees; Marina V Kameneva; Salim E Olia
Journal:  ASAIO J       Date:  2016 Sep-Oct       Impact factor: 2.872

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.