PURPOSE: To evaluate the use of computer-assisted volumetric measurement for the prediction of late enophthalmos and for volume estimation of implant material in the correction of late enophthalmos secondary to orbital blowout fractures (BOF).
METHODS: This is a prospective observational study of 16 patients. Computer-assisted orbital volume measurements were made with the use of axial CT scans. Hertel exophthalmometry was used for the measurement of enophthalmos. The Lancaster test was used for measurement of diplopia. Autogenous bone or hydroxyapatite composite material was used for the repair of orbital defects and the correction of orbital volume expansion in 16 patients with enophthalmos caused by BOF. The volume of implant material was calculated from the orbital volume increment. Patients were followed for an average of 8 months after surgery.
RESULTS: There is a high correlation between the increment of orbital volume and the degree of enophthalmos; 1 cm3 orbital volume increment causes 0.89 mm of enophthalmos. Before surgery, 10 of the 16 patients had moderate enophthalmos (3 to 4 mm) and 6 patients had severe enophthalmos (> or = 5 mm). Six months after surgical intervention, 13 patients (81%) achieved satisfactory results; 3 patients had no enophthalmos and 10 had mild enophthalmos (1 to 2 mm). Three patients had moderate to severe enophthalmos.
CONCLUSIONS: The measurement of orbital volume in patients with BOF can be used to predict the degree of late enophthalmos. Use of the orbital volume increment to determine the amount of implant material can improve the therapeutic outcome in the correction of late enophthalmos caused by BOF.

Entities:  

Mesh:

Year:  2003        PMID: 12918556     DOI: 10.1097/01.iop.0000062848.26273.e5

Source DB:  PubMed          Journal:  Ophthalmic Plast Reconstr Surg        ISSN: 0740-9303            Impact factor:   1.746


  15 in total

1.  'Orbital volume restoration rate after orbital fracture'; a CT-based orbital volume measurement for evaluation of orbital wall reconstructive effect.

Authors:  J M Wi; K H Sung; M Chi
Journal:  Eye (Lond)       Date:  2017-01-13       Impact factor: 3.775

2.  Model-based segmentation in orbital volume measurement with cone beam computed tomography and evaluation against current concepts.

Authors:  Maximilian E H Wagner; Nils-Claudius Gellrich; Karl-Ingo Friese; Matthias Becker; Franz-Erich Wolter; Juergen T Lichtenstein; Marcus Stoetzer; Majeed Rana; Harald Essig
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-06-05       Impact factor: 2.924

Review 3.  New and emerging patient-centered CT imaging and image-guided treatment paradigms for maxillofacial trauma.

Authors:  David Dreizin; Arthur J Nam; Jeffrey Hirsch; Mark P Bernstein
Journal:  Emerg Radiol       Date:  2018-06-20

4.  Functional outcome after surgical treatment of orbital floor fractures.

Authors:  Paul W Poeschl; Arnulf Baumann; Guido Dorner; Guenter Russmueller; Rudolf Seemann; Ferenc Fabian; Rolf Ewers
Journal:  Clin Oral Investig       Date:  2011-08-20       Impact factor: 3.573

5.  A Protocol to Reduce Interobserver Variability in the Computed Tomography Measurement of Orbital Floor Fractures.

Authors:  Chuan Han Ang; Jin Rong Low; Jia Yi Shen; Elijah Zheng Yang Cai; Eileen Chor Hoong Hing; Yiong Huak Chan; Gangadhara Sundar; Thiam Chye Lim
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2015-02-03

6.  Relative difference in orbital volume as an indication for surgical reconstruction in isolated orbital floor fractures.

Authors:  Babak Alinasab; Mats O Beckman; Tony Pansell; Saber Abdi; Anders H Westermark; Pär Stjärne
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2011-12

7.  Orbital volume analysis: validation of a semi-automatic software segmentation method.

Authors:  Jesper Jansen; Ruud Schreurs; Leander Dubois; Thomas J J Maal; Peter J J Gooris; Alfred G Becking
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-07-16       Impact factor: 2.924

8.  Radiological pitfalls in patients with inducible dynamic proptosis.

Authors:  Sharon R Morris; Jean-Louis Desousa; Ian Francis; Lekha Chandrasekharan; Raman Malhotra
Journal:  Open Ophthalmol J       Date:  2008-05-05

9.  Combined Orbital Fractures: Surgical Strategy of Sequential Repair.

Authors:  Su Won Hur; Sung Eun Kim; Kyu Jin Chung; Jun Ho Lee; Tae Gon Kim; Yong-Ha Kim
Journal:  Arch Plast Surg       Date:  2015-07-14

10.  Precision of posttraumatic primary orbital reconstruction using individually bent titanium mesh with and without navigation: a retrospective study.

Authors:  Harald Essig; Lars Dressel; Majeed Rana; Madiha Rana; Horst Kokemueller; Martin Ruecker; Nils-Claudius Gellrich
Journal:  Head Face Med       Date:  2013-07-02       Impact factor: 2.151

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.