Literature DB >> 12909537

Field comparison of inhalable and total dust samplers for assessing airborne dust in swine confinement barns.

Bernardo Z Predicala1, Ronaldo G Maghirang.   

Abstract

Inhalable and total dust sampling devices were compared for evaluating airborne dust in swine confinement buildings. Measurements from three swine facilities (n = 77 paired means) were obtained by area sampling using the IOM (Institute of Occupational Medicine, Edinburgh, U.K.) inhalable dust sampler and a 37-mm closed-face total (TCF) dust sampler. The overall geometric mean IOM concentration (1.18 mg/m(3), geometric standard deviation [GSD] = 2.00) was significantly greater (P < 0.05) than the overall geometric mean TCF concentration (1.08 mg/m(3), GSD = 1.98). Regression analysis with IOM and TCF values as independent and dependent variables, respectively, yielded a factor of 0.86 (+/-0.04 95% confidence interval), which can be used to estimate TCF values from the IOM measurements. Additional paired sampling data were obtained to compare the following pairs of dust samplers: (1) IOM sampler and conical inhalable sampler (CIS) (n = 20 paired means), (2) IOM and open-face total (TOF) dust samplers (n = 14), (3) CIS and TCF samplers (n = 19), and (4) TCF and TOF samplers (n = 8). Paired t-tests showed significantly (P < 0.05) higher IOM concentrations than the CIS sampler; no significant difference (P > 0.05) was found for the other three pairs compared. It may be necessary to establish work-specific conversion coefficients to obtain a reasonable estimate of worker exposure to total dust from measurements using other types of dust sampling devices.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12909537     DOI: 10.1080/10473220301375

Source DB:  PubMed          Journal:  Appl Occup Environ Hyg        ISSN: 1047-322X


  4 in total

1.  Field and wind tunnel comparison of four aerosol samplers using agricultural dusts.

Authors:  Stephen J Reynolds; Jason Nakatsu; Marvin Tillery; Thomas Keefe; John Mehaffy; Peter S Thorne; Kelley Donham; Matthew Nonnenmann; Vijay Golla; Patrick O'shaughnessy
Journal:  Ann Occup Hyg       Date:  2009-05-14

2.  A field evaluation of a single sampler for respirable and inhalable indium and dust measurements at an indium-tin oxide manufacturing facility.

Authors:  Brie Hawley Blackley; Jenna L Gibbs; Kristin J Cummings; Aleksandr B Stefaniak; Ji Young Park; Marcia Stanton; M Abbas Virji
Journal:  J Occup Environ Hyg       Date:  2019-01-28       Impact factor: 2.155

3.  Use of Recirculating Ventilation With Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room.

Authors:  T Renée Anthony; Ralph Altmaier; Samuel Jones; Rich Gassman; Jae Hong Park; Thomas M Peters
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

4.  Airborne cow allergen, ammonia and particulate matter at homes vary with distance to industrial scale dairy operations: an exposure assessment.

Authors:  D'Ann L Williams; Patrick N Breysse; Meredith C McCormack; Gregory B Diette; Shawn McKenzie; Alison S Geyh
Journal:  Environ Health       Date:  2011-08-12       Impact factor: 5.984

  4 in total