Literature DB >> 12904366

Comparison and evaluation of Osiris and Sirscan 2000 antimicrobial susceptibility systems in the clinical microbiology laboratory.

A Nijs1, R Cartuyvels, A Mewis, V Peeters, J L Rummens, K Magerman.   

Abstract

The Osiris and Sirscan 2000 systems are two semiautomated systems that can be used to read and interpret the results on disk diffusion agar plates. They are both used for determination of susceptibility to antimicrobial agents. The present study compared both systems versus the NCCLS standard method of visual reading with a ruler. Both inpatient and outpatient samples with a total of 315 nonfastidious gram-negative strains were obtained. In total, 3724 organism-antimicrobial agent combinations that fulfilled the NCCLS guidelines for disk diffusion susceptibility testing were evaluated prospectively. The results obtained with both systems in comparison with those obtained by the classical nonautomated means of interpretation were excellent, with correlation coefficients of 0.96 for both systems. The overall agreements for susceptibility interpretation were 96.56 and 96.24% with the Osiris and Sirscan systems, respectively. Very major errors were obtained for 8 (1.07%) and 10 (1.34%) organism-antimicrobial agent combinations with the Osiris and Sirscan systems, respectively. In addition, major errors were obtained for 2 (0.07%) and 6 (0.21%) combinations with the Osiris and Sirscan systems, respectively. Minor errors were obtained for 118 and 124 organism-antimicrobial agent combinations with the Osiris and Sirscan systems, respectively. Overall, both the Osiris system and the Sirscan system are comparable and reliable systems for determination of interpretative categories from the zone diameters of standard disk diffusion test plates.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12904366      PMCID: PMC179852          DOI: 10.1128/JCM.41.8.3627-3630.2003

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  Comparison of efficacy and cost-effectiveness of BIOMIC VIDEO and Vitek antimicrobial susceptibility test systems for use in the clinical microbiology laboratory.

Authors:  I Berke; P M Tierno
Journal:  J Clin Microbiol       Date:  1996-08       Impact factor: 5.948

2.  Evaluating agreement with a gold standard in method comparison studies.

Authors:  R T St Laurent
Journal:  Biometrics       Date:  1998-06       Impact factor: 2.571

3.  [Statistical study of the SIRSCAN computerised camera].

Authors:  J Acar; O Bellon; H Chardon; J Charrel; F Goldstein; R Labia; J Sirot
Journal:  Pathol Biol (Paris)       Date:  1997-05

4.  Evaluation of the Sirscan automated zone reader in a clinical microbiology laboratory.

Authors:  A A Medeiros; J Crellin
Journal:  J Clin Microbiol       Date:  2000-04       Impact factor: 5.948

5.  Selection criteria for an antimicrobial susceptibility testing system.

Authors:  J H Jorgensen
Journal:  J Clin Microbiol       Date:  1993-11       Impact factor: 5.948

6.  Evaluation of the BIOMIC video reader system for determining interpretive categories of isolates on the basis of disk diffusion susceptibility results.

Authors:  E K Korgenski; J A Daly
Journal:  J Clin Microbiol       Date:  1998-01       Impact factor: 5.948

  6 in total
  8 in total

1.  Colorimetric-plate method for rapid disk diffusion susceptibility testing of Escherichia coli.

Authors:  Sehnaz Sener; Ibrahim Cagatay Acuner; Yuksel Bek; Belma Durupinar
Journal:  J Clin Microbiol       Date:  2011-01-19       Impact factor: 5.948

Review 2.  Expert systems in clinical microbiology.

Authors:  Trevor Winstanley; Patrice Courvalin
Journal:  Clin Microbiol Rev       Date:  2011-07       Impact factor: 26.132

3.  Synthesis and Antimicrobial, Anticancer and Anti-Oxidant Activities of Novel 2,3-Dihydropyrido[2,3-d]pyrimidine-4-one and Pyrrolo[2,1-b][1,3]benzothiazole Derivatives via Microwave-Assisted Synthesis.

Authors:  Aamal A Al-Mutairi; Hend N Hafez; Abdel-Rhaman B A El-Gazzar; Marwa Y A Mohamed
Journal:  Molecules       Date:  2022-02-12       Impact factor: 4.411

4.  Formulation and evaluation of oral disintegrating films using a natural ingredient against Streptococcus mutans.

Authors:  K Harini; Krishnamachari Janani; Kavalipurapu Venkata Teja; Chandra Mohan; M Sukumar
Journal:  J Conserv Dent       Date:  2022-05-04

5.  Evaluation of an Automated System for Reading and Interpreting Disk Diffusion Antimicrobial Susceptibility Testing of Fastidious Bacteria.

Authors:  Evgeny A Idelevich; Karsten Becker; Janne Schmitz; Dennis Knaack; Georg Peters; Robin Köck
Journal:  PLoS One       Date:  2016-07-08       Impact factor: 3.240

Review 6.  Methods for in vitro evaluating antimicrobial activity: A review.

Authors:  Mounyr Balouiri; Moulay Sadiki; Saad Koraichi Ibnsouda
Journal:  J Pharm Anal       Date:  2015-12-02

Review 7.  A review of the current state of digital plate reading of cultures in clinical microbiology.

Authors:  Daniel D Rhoads; Susan M Novak; Liron Pantanowitz
Journal:  J Pathol Inform       Date:  2015-05-28

8.  Standardisation of disk diffusion results for antibiotic susceptibility testing using the sirscan automated zone reader.

Authors:  Michael Hombach; Reinhard Zbinden; Erik C Böttger
Journal:  BMC Microbiol       Date:  2013-10-08       Impact factor: 3.605

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.