Literature DB >> 12893697

A study on radiation doses and irradiated areas in cerebral embolisation.

C Theodorakou1, J A Horrocks.   

Abstract

Patient radiation doses during interventional radiology procedures may reach the thresholds for radiation-induced skin and eye lens injuries. This study investigates the irradiated areas and doses received by patients undergoing cerebral embolisation, which is regarded as a high dose interventional radiology procedure. For each procedure the fluoroscopic and digital dose-area product (DAP), the fluoroscopic time, the total number of acquired images and entrance-skin dose (ESD) calculated by the angiographic unit were recorded. The ESD was measured by means of thermoluminescent dosimeters. In this study, the skin, eye and thyroid gland doses and the irradiated area for 30 patients were recorded. The average ESD was found to be 0.77 Gy for the posteroanterior plane and 0.78 Gy for the lateral plane. The average DAP was 48 Gy cm(2) for the posteroanterior plane and 58 Gy cm(2) for the lateral plane. The patient's average right eye dose was 60 mGy and the dose to the thyroid gland was 24 mGy. Seven patients received a dose above 1 Gy, one patient exceeded the threshold for transient erythema and one exceeded the threshold for temporary epilation. A good correlation between the DAP and the ESD for both planes has been found. The doctor's eye dose has also been measured for 17 procedures and the average dose per procedure was 0.13 mGy.

Entities:  

Mesh:

Year:  2003        PMID: 12893697     DOI: 10.1259/bjr/26353198

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  8 in total

1.  Cumulative radiation dose during hospitalization for aneurysmal subarachnoid hemorrhage.

Authors:  S I Moskowitz; W J Davros; M E Kelly; D Fiorella; P A Rasmussen; T J Masaryk
Journal:  AJNR Am J Neuroradiol       Date:  2010-05-27       Impact factor: 3.825

2.  Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters.

Authors:  T Moritake; Y Matsumaru; T Takigawa; K Nishizawa; A Matsumura; K Tsuboi
Journal:  AJNR Am J Neuroradiol       Date:  2008-08-21       Impact factor: 3.825

3.  Real-time eye lens dose monitoring during cerebral angiography procedures.

Authors:  M J Safari; J H D Wong; K A A Kadir; N K Thorpe; D L Cutajar; M Petasecca; M L F Lerch; A B Rosenfeld; K H Ng
Journal:  Eur Radiol       Date:  2015-05-23       Impact factor: 5.315

4.  Pediatric patient surface doses in neuroangiography.

Authors:  Natalie A Swoboda; Derek G Armstrong; John Smith; Ellen Charkot; Bairbre L Connolly
Journal:  Pediatr Radiol       Date:  2005-05-26

5.  Patient skin dose during neuroembolization by multiple-point measurement using a radiosensitive indicator.

Authors:  S Suzuki; S Furui; Y Matsumaru; S Nobuyuki; M Ebara; T Abe; D Itoh
Journal:  AJNR Am J Neuroradiol       Date:  2008-04-03       Impact factor: 3.825

6.  Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study.

Authors:  Yon Kwon Ihn; Bum-Soo Kim; Jun Soo Byun; Sang Hyun Suh; Yoo Dong Won; Deok Hee Lee; Byung Moon Kim; Young Soo Kim; Pyong Jeon; Chang-Woo Ryu; Sang-Il Suh; Dae Seob Choi; See Sung Choi; Jin Wook Choi; Hyuk Won Chang; Jae-Wook Lee; Sang Heum Kim; Young Jun Lee; Shang Hun Shin; Soo Mee Lim; Woong Yoon; Hae Woong Jeong; Moon Hee Han
Journal:  Neurointervention       Date:  2016-09-03

7.  Local skin and eye lens equivalent doses in interventional neuroradiology.

Authors:  Michael Sandborg; Sandro Rossitti; Håkan Pettersson
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

8.  Dose evaluation for skin and organ in hepatocellular carcinoma during angiographic procedure.

Authors:  Daniela D'Alessio; Claudia Giliberti; Antonella Soriani; Livio Carpanese; Giuseppe Pizzi; Giulio Vallati; Lidia Strigari
Journal:  J Exp Clin Cancer Res       Date:  2013-10-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.