Literature DB >> 12893637

Synchronization of ventricular fibrillation with real-time feedback pacing: implication to low-energy defibrillation.

Hui-Nam Pak1, Yen-Bin Liu, Hideki Hayashi, Yuji Okuyama, Peng-Sheng Chen, Shien-Fong Lin.   

Abstract

Wavefront synchronization is an important aspect preceding the termination of ventricular fibrillation (VF). We evaluated the defibrillation efficacy of a novel multisite pacing algorithm using optical recording-guided synchronized pacing (SyncP) in the excitable gaps. We compared the effects of SyncP with traditional overdrive pacing (ODP) at 90% of the VF cycle length (VFCL) and high-frequency pacing (HFP; 43-215 Hz) on spontaneous VF termination in isolated rabbit hearts. For SyncP, the pacing current was triggered by the activation of a reference site and was delivered when the optical potential of the pacing site was in an excitable gap. We measured VFCL and the spatial dispersion of VFCL (SDCL) from five points (3 points in the paced area and 2 points in the nonpaced area) and the distribution of phase singularities during the prepacing, pacing, and postpacing periods. The results showed that 1) the VF termination rate of SyncP (16.0%, n = 106) was higher than that of ODP (2.1%, n = 48, P < 0.01) or HFP (1.6%, n = 129, P < 0.0001); 2) energy consumption for SyncP (7.6 +/- 9.3 mJ) was significantly lower than that of ODP (14.0 +/- 14.8 mJ, P < 0.0001); and 3) SyncP, but not ODP or HFP, decreased SDCL in the paced area during the pacing (P < 0.01) and postpacing (P < 0.05) periods compared with the prepacing period. We conclude that SyncP is effective in inducing wavefront synchronization and is more effective at facilitating spontaneous VF termination than non-SyncP.

Entities:  

Mesh:

Year:  2003        PMID: 12893637     DOI: 10.1152/ajpheart.00366.2003

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  11 in total

1.  Regional cooling facilitates termination of spiral-wave reentry through unpinning of rotors in rabbit hearts.

Authors:  Masatoshi Yamazaki; Haruo Honjo; Takashi Ashihara; Masahide Harada; Ichiro Sakuma; Kazuo Nakazawa; Natalia Trayanova; Minoru Horie; Jérôme Kalifa; José Jalife; Kaichiro Kamiya; Itsuo Kodama
Journal:  Heart Rhythm       Date:  2011-08-10       Impact factor: 6.343

2.  A model for multi-site pacing of fibrillation using nonlinear dynamics feedback.

Authors:  Victor D Hosfeld; Steffan Puwal; Keith Jankowski; Bradley J Roth
Journal:  J Biol Phys       Date:  2007-12-07       Impact factor: 1.365

3.  Cardiovascular disease: several small shocks beat one big one.

Authors:  Richard A Gray; John P Wikswo
Journal:  Nature       Date:  2011-07-13       Impact factor: 49.962

4.  GPU acceleration of optical mapping algorithm for cardiac electrophysiology.

Authors:  Pingfan Meng; Ali Irturk; Ryan Kastner; Andrew McCulloch; Jeffrey Omens; Adam Wright
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

5.  Low energy defibrillation in human cardiac tissue: a simulation study.

Authors:  Stuart W Morgan; Gernot Plank; Irina V Biktasheva; Vadim N Biktashev
Journal:  Biophys J       Date:  2009-02-18       Impact factor: 4.033

6.  Termination of atrial fibrillation using pulsed low-energy far-field stimulation.

Authors:  Flavio H Fenton; Stefan Luther; Elizabeth M Cherry; Niels F Otani; Valentin Krinsky; Alain Pumir; Eberhard Bodenschatz; Robert F Gilmour
Journal:  Circulation       Date:  2009-07-27       Impact factor: 29.690

7.  Synchronized defibrillation for ventricular fibrillation.

Authors:  Karen M Darragh; Ganesh Manoharan; Cesar Navarro; Simon J Walsh; John D Allen; John McC Anderson; Aa Jennifer Adgey
Journal:  Eur Heart J Acute Cardiovasc Care       Date:  2012-12

Review 8.  Electrical Stimulation for Low-Energy Termination of Cardiac Arrhythmias: a Review.

Authors:  Skylar Buchan; Ronit Kar; Mathews John; Allison Post; Mehdi Razavi
Journal:  Cardiovasc Drugs Ther       Date:  2021-08-07       Impact factor: 3.727

9.  Capture of activation during ventricular arrhythmia using distributed stimulation.

Authors:  Jason M Meunier; Sanjiv Ramalingam; Shien-Fong Lin; Abhijit R Patwardhan
Journal:  J Interv Card Electrophysiol       Date:  2007-05-23       Impact factor: 1.900

10.  A New Efficient Method for Detecting Phase Singularity in Cardiac Fibrillation.

Authors:  Young-Seon Lee; Jun-Seop Song; Minki Hwang; Byounghyun Lim; Boyoung Joung; Hui-Nam Pak
Journal:  PLoS One       Date:  2016-12-01       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.