Ultrasound indentation of bovine knee articular cartilage in situ.

Mikko S Laasanen1, Simo Saarakkala, Juha Töyräs, Jani Hirvonen, Jarno Rieppo, Rami K Korhonen, Jukka S Jurvelin.   

Abstract

We have earlier developed a handheld ultrasound indentation instrument for the diagnosis of articular cartilage degeneration. In ultrasound indentation, cartilage is compressed with the ultrasound transducer. Tissue thickness and deformation are calculated from the A-mode ultrasound signal and the stress applied is registered with the strain gauges. In this study, the applicability of the ultrasound indentation instrument to quantify site-dependent variation in the mechano-acoustic properties of bovine knee cartilage was investigated. Osteochondral blocks (n=6 per site) were prepared from the femoral medial condyle (FMC), the lateral facet of the patello-femoral groove (LPG) and the medial tibial plateau (MTP). Cartilage stiffness (dynamic modulus, E(dyn)), as obtained with the ultrasound indentation instrument in situ, correlated highly linearly (r=0.913, p<0.01) with the values obtained using the reference material-testing device in vitro. Reproducibility (standardized coefficient of variation) of the ultrasound indentation measurements was 5.2%, 1.7% and 3.1% for E(dyn), ultrasound reflection coefficient of articular surface (R) and thickness, respectively. E(dyn) and R were site dependent (p<0.05, Kruskall-Wallis H test). E(dyn) was significantly higher (p<0.05, Kruskall-Wallis Post Hoc test) in LPG (mean+/-SD: 10.1+/-3.1MPa) than in MTP (2.9+/-1.4MPa). In FMC, E(dyn) was 4.6+/-1.3MPa. R was significantly (p<0.05) lower at MTP (2.0+/-0.7%) than at other sites (FMC: 4.2+/-0.9%; LPG: 4.4+/-0.8%). Cartilage glycosaminoglycan concentration, as quantified with the digital densitometry, correlated positively with E(dyn) (r=0.678, p<0.01) and especially with the equilibrium Young's modulus (reference device, r=0.874, p<0.01) but it was not associated with R (r=0.294, p=0.24). We conclude that manual measurements are reproducible and the instrument may be used for detection of cartilage quality in situ. Especially, combined measurement of thickness, E(dyn) and R provides valuable diagnostic information on cartilage status.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12893034     DOI: 10.1016/s0021-9290(03)00163-5

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  10 in total

1.  Indentation test of soft tissues with curved substrates: a finite element study.

Authors:  M H Lu; Y P Zheng
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

2.  An optical coherence tomography (OCT)-based air jet indentation system for measuring the mechanical properties of soft tissues.

Authors:  Yan-Ping Huang; Yong-Ping Zheng; Shu-Zhe Wang; Zhong-Ping Chen; Qing-Hua Huang; Yong-Hong He
Journal:  Meas Sci Technol       Date:  2009-01       Impact factor: 2.046

3.  Observation of sGAG content of human hip joint cartilage in different old age groups based on EPIC micro-CT.

Authors:  Xiao-Fei Li; Xi-Ran Cai; Fan Fan; Hai-Jun Niu; Shu-Yu Li; De-Yu Li; Yu-Bo Fan; Yi-Xian Qin
Journal:  Connect Tissue Res       Date:  2015-02-03       Impact factor: 3.417

Review 4.  Non-invasive and in vivo assessment of osteoarthritic articular cartilage: a review on MRI investigations.

Authors:  Ahmad Fadzil Mohd Hani; Dileep Kumar; Aamir Saeed Malik; Raja Mohd Kamil Raja Ahmad; Ruslan Razak; Azman Kiflie
Journal:  Rheumatol Int       Date:  2014-05-31       Impact factor: 2.631

5.  Nondestructive assessment of sGAG content and distribution in normal and degraded rat articular cartilage via EPIC-microCT.

Authors:  L Xie; A S P Lin; R E Guldberg; M E Levenston
Journal:  Osteoarthritis Cartilage       Date:  2009-09-01       Impact factor: 6.576

6.  Apparatus and Method for Rapid Detection of Acoustic Anisotropy in Cartilage.

Authors:  Mostafa Motavalli; Cheyenne Jones; Jim A Berilla; Ming Li; Mark D Schluchter; Joseph M Mansour; Jean F Welter
Journal:  J Med Biol Eng       Date:  2020-03-18       Impact factor: 1.553

7.  High-Frequency Acoustic Imaging Using Adhesive-Free Polymer Transducer.

Authors:  Abhishek Ranjan; Chengxiang Peng; Sanat Wagle; Frank Melandsø; Anowarul Habib
Journal:  Polymers (Basel)       Date:  2021-04-30       Impact factor: 4.329

8.  Quantifying birefringence in the bovine model of early osteoarthritis using polarisation-sensitive optical coherence tomography and mechanical indentation.

Authors:  Matthew Goodwin; Bastian Bräuer; Stephen Lewis; Ashvin Thambyah; Frédérique Vanholsbeeck
Journal:  Sci Rep       Date:  2018-06-05       Impact factor: 4.379

9.  Finite deformation elastography of articular cartilage and biomaterials based on imaging and topology optimization.

Authors:  Luyao Cai; Eric A Nauman; Claus B W Pedersen; Corey P Neu
Journal:  Sci Rep       Date:  2020-05-14       Impact factor: 4.379

10.  3D High-Frequency Ultrasound Imaging of Cartilage-Bone Interface Compared with Micro-CT.

Authors:  Yanping Huang; Choi Han Chan; Guangquan Zhou; Yongping Zheng; Chun Hoi Yan; Chunyi Wen
Journal:  Biomed Res Int       Date:  2020-05-31       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.