Influence of peg design and cement mantle thickness on pull-out strength of glenoid component pegs.

R W Nyffeler1, C Anglin, R Sheikh, C Gerber.   

Abstract

Fixation of the glenoid component is critical to the outcome of total shoulder arthroplasty. In an in vitro study, we analysed the effect of surface design and thickness of the cement mantle on the pull-out strength of the polyethylene pegs which are considered essential for fixation of cemented glenoid components. The macrostructure and surface of the pegs and the thickness of the cement mantle were studied in human glenoid bone. The lowest pull-out forces, 20 +/- 5 N, were for cylindrical pegs with a smooth surface fixed in the glenoid with a thin cement mantle. The highest values, 425 +/- 7 N, were for threaded pegs fixed with a thicker cement mantle. Increasing the diameter of the hole into which the peg is inserted from 5.2 to 6.2 mm thereby increasing the thickness of the cement mantle, improved the mean pull-out force for the pegs tested.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12892204

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  Peri-implant stress correlates with bone and cement morphology: Micro-FE modeling of implanted cadaveric glenoids.

Authors:  Hwabok Wee; April D Armstrong; Wesley W Flint; Allen R Kunselman; Gregory S Lewis
Journal:  J Orthop Res       Date:  2015-06-18       Impact factor: 3.494

2.  Effect of glenoid perforation during total shoulder arthroplasty on glenoid component cement fixation and suprascapular nerve.

Authors:  Gregory I Pace; Rachel A Thomas; Connor L Zale; Gregory S Lewis; Raymond Y Kim; H Mike Kim
Journal:  Shoulder Elbow       Date:  2020-01-13

3.  Stability of small pegs for cementless implant fixation.

Authors:  Diogo M Geraldes; Ulrich Hansen; Jonathan Jeffers; Andrew A Amis
Journal:  J Orthop Res       Date:  2017-05-23       Impact factor: 3.494

4.  Cadaveric study validating in vitro monitoring techniques to measure the failure mechanism of glenoid implants against clinical CT.

Authors:  Sarah Junaid; Thomas Gregory; Shirley Fetherston; Roger Emery; Andrew A Amis; Ulrich Hansen
Journal:  J Orthop Res       Date:  2018-04-25       Impact factor: 3.494

5.  Failure mechanism of the all-polyethylene glenoid implant.

Authors:  Junaid Sarah; Gupta Sanjay; Sanghavi Sanjay; Anglin Carolyn; Roger Emery; Amis Andrew; Hansen Ulrich
Journal:  J Biomech       Date:  2009-11-25       Impact factor: 2.712

6.  A CT scan protocol for the detection of radiographic loosening of the glenoid component after total shoulder arthroplasty.

Authors:  Thomas Gregory; Ulrich Hansen; Monica Khanna; Celine Mutchler; Saik Urien; Andrew A Amis; Bernard Augereau; Roger Emery
Journal:  Acta Orthop       Date:  2013-11-29       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.