Literature DB >> 12892184

Dislocation after total hip replacement in relation to metal-on-metal bearing surfaces.

M T Clarke1, P T H Lee, R N Villar.   

Abstract

Metal-on-metal (MOM) is a commonly used bearing notable for its 'suction fit' when lubricated. In this study, we examined the capacity for MOM bearings to protect against dislocation after total hip replacement (THR). We undertook a clinical investigation to compare the rate of dislocation of MOM bearings with those of ceramic-on-polyethylene (COP) bearings and found that one MOM bearing dislocated in a series of 109 hips (0.9%) compared with nine of 145 hips (6.2%) in the COP group (p = 0.02). We also performed an in vitro investigation comparing the peak forces generated during forced separation of the two bearings of the same dimensions at velocities from 1 to 50 cm/s. This revealed that the MOM bearing generated significant resistance to separation at all velocities (maximum mean 24 N), whereas the COP did not (maximum mean 1.9 N, p < 0.001). We conclude that MOM bearings are more stable to dislocation than COP bearings as a result of the interfacial forces provided by a thin, lubricating fluid.

Entities:  

Mesh:

Year:  2003        PMID: 12892184

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  8 in total

1.  Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?

Authors:  Seung-Hoon Baek; Won Keun Kim; Jun Young Kim; Shin-Yoon Kim
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

2.  Mechanical failure of metal-polyethylene sandwich liner in metal-on-metal total hip replacement.

Authors:  Yasushi Oshima; Joseph F Fetto
Journal:  J Mater Sci Mater Med       Date:  2015-01-20       Impact factor: 3.896

Review 3.  Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidence.

Authors:  Art Sedrakyan; Sharon-Lise T Normand; Stefan Dabic; Samantha Jacobs; Stephen Graves; Danica Marinac-Dabic
Journal:  BMJ       Date:  2011-11-29

Review 4.  Personalized Hip Joint Replacement with Large Diameter Head: Current Concepts.

Authors:  Pascal-André Vendittoli; Sagi Martinov; Mina Wahba Morcos; Sivan Sivaloganathan; William G Blakeney
Journal:  J Clin Med       Date:  2022-03-30       Impact factor: 4.241

Review 5.  Arthroplasty in Femoral Head Osteonecrosis.

Authors:  Yoon Je Cho; Dong Cheol Nam; Kwangyoung Jung
Journal:  Hip Pelvis       Date:  2014-06-30

6.  Is the Survivorship of Birmingham Hip Resurfacing Better Than Selected Conventional Hip Arthroplasties in Men Younger Than 65 Years of Age? A Study from the Australian Orthopaedic Association National Joint Replacement Registry.

Authors:  James Stoney; Stephen E Graves; Richard N de Steiger; Sophia Rainbird; Thu-Lan Kelly; Alesha Hatton
Journal:  Clin Orthop Relat Res       Date:  2020-11       Impact factor: 4.755

7.  MRI does not detect acetabular osteolysis around metal-on-metal Birmingham THA.

Authors:  Wenzel Waldstein; Tom Schmidt-Braekling; Friedrich Boettner
Journal:  Arch Orthop Trauma Surg       Date:  2014-05-18       Impact factor: 3.067

8.  The influence of bearing surfaces on revisions due to dislocations in total hip arthroplasty.

Authors:  Francesco Castagnini; Barbara Bordini; Monica Cosentino; Cristina Ancarani; Federica Mariotti; Federico Biondi; Cesare Faldini; Francesco Traina
Journal:  J Mater Sci Mater Med       Date:  2021-09-15       Impact factor: 3.896

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.