Dual-energy imaging in full-field digital mammography: a phantom study.

A Taibi1, S Fabbri, P Baldelli, C di Maggio, G Gennaro, M Marziani, A Tuffanelli, M Gambaccini.   

Abstract

A dual-energy technique which employs the basis decomposition method is being investigated for application to digital mammography. A three-component phantom, made up of plexiglas, polyethylene, and water, was doubly exposed with the full-field digital mammography system manufactured by General Electric. The 'low' and 'high' energy images were recorded with a Mo/Mo anode-filter combination and a Rh/Rh combination, respectively. The total dose was kept within the acceptable levels of conventional mammography. The first hybrid images obtained with the dual-energy algorithm are presented in comparison with a conventional radiograph of the phantom. Image-quality characteristics at contrast cancellation angles between plexiglas and water are discussed. Preliminary results show that a combination of a standard Mo-anode 28 kV radiograph with a Rh-anode 49 kV radiograph provides the best compromise between image-quality and dose in the hybrid image.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12884927     DOI: 10.1088/0031-9155/48/13/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Quantification of breast density with dual energy mammography: a simulation study.

Authors:  Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

2.  Quantification of breast density with dual energy mammography: an experimental feasibility study.

Authors:  Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

3.  Compositional breast imaging using a dual-energy mammography protocol.

Authors:  Aurelie D Laidevant; Serghei Malkov; Chris I Flowers; Karla Kerlikowske; John A Shepherd
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

4.  The impact of calibration phantom errors on dual-energy digital mammography.

Authors:  Xuanqin Mou; Xi Chen; Lijun Sun; Hengyong Yu; Zhen Ji; Lei Zhang
Journal:  Phys Med Biol       Date:  2008-10-20       Impact factor: 3.609

5.  Multispectral X-ray imaging to distinguish among dental materials.

Authors:  Ann-Christin Peter; Matthias Schnaubelt; Michael Gente
Journal:  Imaging Sci Dent       Date:  2017-12-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.