Literature DB >> 12883400

Performance of noninvasive partial CO2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery.

Yoshifumi Kotake1, Kiyoshi Moriyama, Yasushi Innami, Hideyuki Shimizu, Toshihiko Ueda, Hiroshi Morisaki, Junzo Takeda.   

Abstract

BACKGROUND: In the partial CO(2) rebreathing method, monitored changes in CO(2) elimination and end-tidal CO(2) in response to a brief rebreathing period are used to estimate cardiac output. However, dynamic changes in CO(2) production during ischemia and reperfusion may affect the accuracy of these estimates. This study was designed to compare measurements of cardiac output as produced by the partial CO(2) rebreathing (NICO), bolus (BCO), and continuous thermodilution (CCO) methods of monitoring cardiac output.
METHODS: Cardiac output was continuously monitored using both NICO and CCO in 28 patients undergoing aortic reconstruction. BCO measurements were taken at the following intervals when hemodynamic stability was achieved: (1) after anesthetic induction; (2) during aortic cross-clamp; (3) at reperfusion of the iliac artery; and, (4) during peritoneal closure.
RESULTS: The bias and precision (1 SD) derived from all the measurements between NICO and BCO was -0.58 +/- 0.9 l/min, whereas for CCO and BCO it was 0.38 +/- 1.17 l/min. The bias between NICO and BCO was small after anesthetic induction and during cross-clamp, but increased following reperfusion. The bias between CCO and BCO was relatively small until reperfusion but increased significantly at peritoneal closure.
CONCLUSIONS: Results indicate that in aortic reconstruction surgery the performance of NICO monitoring is comparable with that of CCO; however, the direction of bias in these continuous measurement devices is the opposite.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12883400     DOI: 10.1097/00000542-200308000-00009

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  14 in total

Review 1.  [Measurement of cardiac output].

Authors:  D A Reuter; A E Goetz
Journal:  Anaesthesist       Date:  2005-11       Impact factor: 1.041

Review 2.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

3.  Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices.

Authors:  Pierre Squara; Maurizio Cecconi; Andrew Rhodes; Mervyn Singer; Jean-Daniel Chiche
Journal:  Intensive Care Med       Date:  2009-07-11       Impact factor: 17.440

Review 4.  [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

Authors:  G Pestel; K Fukui; M Higashi; I Schmidtmann; C Werner
Journal:  Anaesthesist       Date:  2018-06       Impact factor: 1.041

5.  End-tidal carbon dioxide monitoring indicates recovery from cardiogenic shock in patients receiving percutaneous cardiopulmonary support.

Authors:  Takuji Yoshida; Masazumi Watanabe; Mikiko Murakami; Hitoshi Furukawa; Hideki Nakahara
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

Review 6.  Noninvasive Monitoring and Potential for Patient Outcome.

Authors:  Susana Vacas; Maxime Cannesson
Journal:  J Cardiothorac Vasc Anesth       Date:  2019-08       Impact factor: 2.628

7.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

8.  Improved accuracy of cardiac output estimation by the partial CO2 rebreathing method.

Authors:  Yoshifumi Kotake; Takashige Yamada; Hiromasa Nagata; Takeshi Suzuki; Ryohei Serita; Nobuyuki Katori; Junzo Takeda; Hideyuki Shimizu
Journal:  J Clin Monit Comput       Date:  2009-03-20       Impact factor: 2.502

9.  Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis.

Authors:  Karim Kouz; Frederic Michard; Alina Bergholz; Christina Vokuhl; Luisa Briesenick; Phillip Hoppe; Moritz Flick; Gerhard Schön; Bernd Saugel
Journal:  Crit Care       Date:  2021-03-29       Impact factor: 9.097

10.  Technological advancements in the care of the trauma patient.

Authors:  J J Siracuse; N N Saillant; C J Hauser
Journal:  Eur J Trauma Emerg Surg       Date:  2011-11-09       Impact factor: 3.693

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.