Rapid evaluation of right and left ventricular function and mass using real-time true-FISP cine MR imaging without breath-hold: comparison with segmented true-FISP cine MR imaging with breath-hold.

Yoshiro Hori1, Naoaki Yamada, Masahiro Higashi, Nobuhiko Hirai, Satoshi Nakatani.   

Abstract

PURPOSE: To evaluate the accuracy of cardiac function measured with real-time true fast imaging with steady-state precession (True-FISP) cine without breath-hold compared with those measured from segmented True-FISP cine with breath-hold.
METHODS: Eighteen consecutive patients and six healthy volunteers were enrolled in the study group. Both real-time multislice True-FISP cine imaging without breath-hold and single-slice segmented True-FISP cine imaging with multiple breath-holds were performed in short-axis imaging sections to encompass the entire ventricles. Vertical long-axis cine imaging using real-time True-FISP cine sequence without breath-hold was performed to evaluate heart motion during respiration in 13 subjects. Ventricular volume and mass were evaluated by four observers independently with manual tracing.
RESULTS: Real-time True-FISP cine quality was sufficient for contour detection in all 24 subjects. Cardiodynamic measurements based on real-time True-FISP cine correlated well with those based on segmented True-FISP cine [left ventricular (LV) end-diastolic volume: r = 0.98; LV end-systolic volume: r = 0.98; LV ejection fraction: r = 0.91; LV mass: r = 0.96; right ventricular (RV) end-diastolic volume: r = 0.89; RV end-systolic volume: r = 0.94; RV ejection fraction: r = 0.79]. Intra- and interobserver variability were sufficiently small in real-time True-FISP cine without breath-hold. Heart motion during respiration along the long axis of the left ventricle (2.2 mm to 3.7 mm) was much less than the slice interval (10 mm), confirming that misregistration of slice position during respiration was low.
CONCLUSION: Real-time True-FISP cine without breath-hold has high reproducibility and is applicable to patients with severe cardiac dysfunction and/or arrhythmias.

Entities:  

Mesh:

Year:  2003        PMID: 12882075     DOI: 10.1081/jcmr-120022260

Source DB:  PubMed          Journal:  J Cardiovasc Magn Reson        ISSN: 1097-6647            Impact factor:   5.364


  13 in total

1.  Use of cardiac magnetic resonance imaging to evaluate cardiac structure, function and fibrosis in children with infantile Pompe disease on enzyme replacement therapy.

Authors:  Piers C A Barker; Sara K Pasquali; Stephen Darty; Richard J Ing; Jennifer S Li; Raymond J Kim; Stephanie DeArmey; Priya S Kishnani; Michael J Campbell
Journal:  Mol Genet Metab       Date:  2010-07-23       Impact factor: 4.797

2.  Assessment of left ventricular volumes and function by cine-MR imaging depending on the investigator's experience.

Authors:  A Bailly; J Lipiecki; P Chabrot; A Alfidja; J M Garcier; S Ughetto; J Ponsonnaille; L Boyer
Journal:  Surg Radiol Anat       Date:  2008-10-08       Impact factor: 1.246

3.  Comparison of two single-breath-held 3-D acquisitions with multi-breath-held 2-D cine steady-state free precession MRI acquisition in children with single ventricles.

Authors:  Lamya A Atweh; Nicholas A Dodd; Ramkumar Krishnamurthy; Amol Pednekar; Zili D Chu; Rajesh Krishnamurthy
Journal:  Pediatr Radiol       Date:  2016-02-22

4.  Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction.

Authors:  Michael S Hansen; Thomas S Sørensen; Andrew E Arai; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-12-21       Impact factor: 4.668

5.  Highly accelerated real-time cardiac cine MRI using k-t SPARSE-SENSE.

Authors:  Li Feng; Monvadi B Srichai; Ruth P Lim; Alexis Harrison; Wilson King; Ganesh Adluru; Edward V R Dibella; Daniel K Sodickson; Ricardo Otazo; Daniel Kim
Journal:  Magn Reson Med       Date:  2012-08-06       Impact factor: 4.668

6.  True real-time cardiac MRI in free breathing without ECG synchronization using a novel sequence with radial k-space sampling and balanced SSFP contrast mode.

Authors:  Ralf W Bauer; Isabel Radtke; Kai T Block; Maya C Larson; J Matthias Kerl; Renate Hammerstingl; Thomas G Graf; Thomas J Vogl; Shuo Zhang
Journal:  Int J Cardiovasc Imaging       Date:  2013-01-19       Impact factor: 2.357

7.  High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting.

Authors:  Peter Kellman; Christophe Chefd'hotel; Christine H Lorenz; Christine Mancini; Andrew E Arai; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

Review 8.  MR and CT Imaging for the Evaluation of Pulmonary Hypertension.

Authors:  Benjamin H Freed; Jeremy D Collins; Christopher J François; Alex J Barker; Michael J Cuttica; Naomi C Chesler; Michael Markl; Sanjiv J Shah
Journal:  JACC Cardiovasc Imaging       Date:  2016-06

9.  Clinical validation of free breathing respiratory triggered retrospectively cardiac gated cine balanced steady-state free precession cardiovascular magnetic resonance in sedated children.

Authors:  Rajesh Krishnamurthy; Amol Pednekar; Lamya A Atweh; Esben Vogelius; Zili David Chu; Wei Zhang; Shiraz Maskatia; Prakash Masand; Shaine A Morris; Ramkumar Krishnamurthy; Raja Muthupillai
Journal:  J Cardiovasc Magn Reson       Date:  2015-01-14       Impact factor: 5.364

Review 10.  Cardiovascular magnetic resonance artefacts.

Authors:  Pedro F Ferreira; Peter D Gatehouse; Raad H Mohiaddin; David N Firmin
Journal:  J Cardiovasc Magn Reson       Date:  2013-05-22       Impact factor: 5.364