Literature DB >> 12881826

Cardiorespiratory fitness and functional capacity assessed by the 20-meter shuttle walking test in patients with coronary artery disease.

Mathieu Gayda1, Dominique Choquet, Abdou Temfemo, Saïd Ahmaïdi.   

Abstract

OBJECTIVE: To validate the 20-meter shuttle walking test (20MST) in the assessment of maximal oxygen consumption (VO(2)max) and maximal speed in patients with coronary artery disease (CAD).
DESIGN: Single-sample validity study.
SETTING: Cardiac rehabilitation service in France. PARTICIPANTS: Seventeen men with CAD.
INTERVENTIONS: Subjects underwent a symptom-limited treadmill test (SLTT) in a laboratory, with a speed starting at 2.5km/h and increasing by 0.5km/h every minute, and performed an adapted 20MST in a corridor, with a speed starting at 3km/h and increasing by 1km/h every minute until exhaustion. MAIN OUTCOME MEASURES: VO(2) measured during the 20MST with the Cosmed K2 telemetric gas analyzer (K2 VO(2)), estimated VO(2) calculated by the Léger equation (Léger VO(2)) from the maximal speed obtained during the 20MST, and VO(2) measured during the SLTT (SLTT VO(2)). Maximal speeds attained on the treadmill and on the 20MST were also compared.
RESULTS: A significant (P<.0001) difference was observed between the Léger estimate of VO(2) and those of K2 VO(2) and SLTT VO(2) (mean +/- standard deviation, 12.28+/-5.90mL. min(-1).kg(-1) vs 23.04+/-7.17 and 22.56+/-6.29mL.min(-1).kg(-1)). No difference was found between the treadmill and the 20MST maximal speeds (6.73+/-0.91km/h, 6.78+/-1.23km/h, respectively). Measured with the Cosmed K2, a significant relationship existed between VO(2) and each speed level (r=.95, P<.0001; VO(2)=4.24x speed-7.37, standard estimation error=2.29mL.min(-1).kg(-1)).
CONCLUSION: Maximal VO(2) and maximal speed measured on the treadmill did not differ significantly from those obtained on the 20MST. The current 20MST equation (Léger equation) was not valid to estimate VO(2) in CAD patients. A modified prediction equation of VO(2) was given and would need a larger number of patients to be generalized.

Entities:  

Mesh:

Year:  2003        PMID: 12881826     DOI: 10.1016/s0003-9993(03)00036-4

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  4 in total

1.  Comparison of gas exchange data using the Aquatrainer system and the facemask with Cosmed K4b2 during exercise in healthy subjects.

Authors:  Mathieu Gayda; Laurent Bosquet; Martin Juneau; Thibaut Guiraud; Jean Lambert; Anil Nigam
Journal:  Eur J Appl Physiol       Date:  2010-01-05       Impact factor: 3.078

2.  Exercise performance, physical activity, and health-related quality of life in participants with stable angina.

Authors:  Andrew W Gardner; Polly S Montgomery; Raphael M Ritti-Dias; Udho Thadani
Journal:  Angiology       Date:  2011-03-18       Impact factor: 3.619

3.  Comparison of functional exercise capacity, quality of life and respiratory and peripheral muscle strength between patients with stable angina and healthy controls.

Authors:  Irem Huzmeli; Aysel-Yildiz Ozer; Oguz Akkus; Nihan Katayıfcı; Fatih Sen; Saadet Ufuk Yurdalan; Mine Gulden Polat
Journal:  J Int Med Res       Date:  2020-12       Impact factor: 1.671

4.  INFLUENCE OF DIABETES ON AMBULATION AND INFLAMMATION IN MEN AND WOMEN WITH SYMPTOMATIC PERIPHERAL ARTERY DISEASE.

Authors:  Andrew W Gardner; Donald E Parker; Polly S Montgomery; Danuta Sosnowska; Ana I Casanegra; Zoltan Ungvari; Anna Csiszar; Sarah X Zhang; Josh J Wang; William E Sonntag
Journal:  J Clin Transl Endocrinol       Date:  2015-12-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.