Literature DB >> 12878264

An investigation of the toxicity of gadolinium based MRI contrast agents using neutron activation analysis.

M E Bartolini1, J Pekar, D R Chettle, F McNeill, A Scott, J Sykes, F S Prato, G R Moran.   

Abstract

The toxicity of gadolinium (Gd) based MRI contrast agents, is based upon the amount of Gd that dissociates from its chelate and deposits in tissues. In this study, the toxicities of two contrast agents were tested using different injection strategies in two animal models. Following a bolus injection of 0.2 mmol/kg of Gd-DTPA in a pilot study with a single canine, Gd levels were as high as 2.05 +/- 0.17 ppm and 0.47 +/- 0.11 ppm 2 weeks post injection in the kidney and liver tissues, respectively. To evaluate the role that the injection strategy plays in toxicity, 0.8 mmol/kg of Gd-(HP-DO3A) was injected into rats, in a second study, via bolus and constant infusion techniques. Gd was only detected in the kidney in the bolus injected rats but in the lung as well in the constant infusion injected rats. Concentrations detected in the kidney for both strategies, were comparable within error: 1.37 +/- 0.46 ppm for the bolus and 1.24 +/- 0.39 ppm for the bolus/constant infusion strategy and 0.16 +/- 0.14 ppm in the lung for the constant infusion technique. The contrast infusion technique does not appear to present an increased risk of toxicity over the bolus technique except perhaps to a small degree in the lung.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12878264     DOI: 10.1016/s0730-725x(03)00081-x

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  12 in total

Review 1.  The translational role of diffusion tensor image analysis in animal models of developmental pathologies.

Authors:  Ipek Oguz; Matthew S McMurray; Martin Styner; Josephine M Johns
Journal:  Dev Neurosci       Date:  2012-05-24       Impact factor: 2.984

2.  In vivo detection of oxidation-specific epitopes in atherosclerotic lesions using biocompatible manganese molecular magnetic imaging probes.

Authors:  Karen C Briley-Saebo; Tuyen Hoang Nguyen; Alexander M Saeboe; Young-Seok Cho; Sung Kee Ryu; Eugenia R Volkova; Eugenia Volkava; Stephen Dickson; Gregor Leibundgut; Philipp Wiesner; Philipp Weisner; Simone Green; Florence Casanada; Yury I Miller; Walter Shaw; Joseph L Witztum; Zahi A Fayad; Sotirios Tsimikas
Journal:  J Am Coll Cardiol       Date:  2012-02-07       Impact factor: 24.094

3.  Salicylic Acid Conjugated Dendrimers Are a Tunable, High Performance CEST MRI NanoPlatform.

Authors:  Wojciech G Lesniak; Nikita Oskolkov; Xiaolei Song; Bachchu Lal; Xing Yang; Martin Pomper; John Laterra; Sridhar Nimmagadda; Michael T McMahon
Journal:  Nano Lett       Date:  2016-03-01       Impact factor: 11.189

4.  Biofunctionalized prussian blue nanoparticles for multimodal molecular imaging applications.

Authors:  Jennifer M Vojtech; Juliana Cano-Mejia; Matthieu F Dumont; Raymond W Sze; Rohan Fernandes
Journal:  J Vis Exp       Date:  2015-04-28       Impact factor: 1.355

5.  Near infrared-fluorescent and magnetic resonance imaging molecular probe with high T1 relaxivity for in vivo multimodal imaging.

Authors:  Kevin Guo; Mikhail Y Berezin; Jie Zheng; Walter Akers; Franck Lin; Bao Teng; Olga Vasalatiy; Amir Gandjbakhche; Gary L Griffiths; Samuel Achilefu
Journal:  Chem Commun (Camb)       Date:  2010-04-13       Impact factor: 6.222

6.  Shape memory polymers with enhanced visibility for magnetic resonance- and X-ray imaging modalities.

Authors:  A C Weems; J M Szafron; A D Easley; S Herting; J Smolen; D J Maitland
Journal:  Acta Biomater       Date:  2017-03-01       Impact factor: 8.947

Review 7.  Biochemical safety profiles of gadolinium-based extracellular contrast agents and nephrogenic systemic fibrosis.

Authors:  Hale Ersoy; Frank J Rybicki
Journal:  J Magn Reson Imaging       Date:  2007-11       Impact factor: 4.813

8.  Effects of image contrast on functional MRI image registration.

Authors:  Javier Gonzalez-Castillo; Kristen N Duthie; Ziad S Saad; Carlton Chu; Peter A Bandettini; Wen-Ming Luh
Journal:  Neuroimage       Date:  2012-11-02       Impact factor: 6.556

9.  Molecular imaging probe development: a chemistry perspective.

Authors:  Donald D Nolting; Michael L Nickels; Ning Guo; Wellington Pham
Journal:  Am J Nucl Med Mol Imaging       Date:  2012-07-10

10.  An [18F]-Positron Emitting Fluorophore Allows Safe Evaluation of Small Molecule Distribution in the CSF, CSF Fistulas, and CNS Device Placement.

Authors:  Hua Guo; Harikrishna Kommidi; Uday B Maachani; Julia C Voronina; Weiqi Zhang; Rajiv S Magge; Jana Ivanidze; Amy P Wu; Mark M Souweidane; Omer Aras; Richard Ting
Journal:  Mol Pharm       Date:  2019-07-10       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.