Literature DB >> 12878252

Assessment of the acoustic properties of common tissue-mimicking test phantoms.

J E Browne1, K V Ramnarine, A J Watson, P R Hoskins.   

Abstract

Ultrasound (US) test phantoms incorporating tissue-mimicking materials (TMMs) play an important role in the quality control (QC) and performance testing of US equipment. Three commercially available TMMs (Zerdine from CIRS Inc.; condensed-milk-based gel from Gammex RMI; urethane-rubber-based from ATS Labs) and a noncommercial agar-based TMM, were investigated. Acoustic properties were measured over the frequency range 2.25 to 15 MHz at a range of ambient temperatures (10 to 35 degrees C). The acoustic velocity of the TMMs remained relatively constant with increasing frequency. Only the agar-based TMM had a linear increase of attenuation with frequency, with the other materials exhibiting nonlinear responses to varying degrees (f(1.08) to f(1.83)). The acoustic velocity and attenuation coefficient of all the TMMs varied with temperature, with the urethane-rubber TMM showing the greatest variation of +/- 1.2% for acoustic velocity and +/- 12% for attenuation coefficient. The data obtained in this study highlight the importance of greater knowledge of the acoustic behavior of TMMs to variations in both frequency and temperature, to ensure that accurate and precise measurements are obtained during QC and performance testing.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12878252     DOI: 10.1016/s0301-5629(03)00053-x

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  35 in total

1.  Development of a training phantom for compression breast elastography-comparison of various elastography systems and numerical simulations.

Authors:  Kavitha Manickam; Machireddy Ramasubba Reddy; Suresh Seshadri; Bagyam Raghavan
Journal:  J Med Imaging (Bellingham)       Date:  2015-12-17

2.  Histotripsy Thrombolysis on Retracted Clots.

Authors:  Xi Zhang; Gabe E Owens; Charles A Cain; Hitinder S Gurm; Jonathan Macoskey; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2016-05-07       Impact factor: 2.998

3.  Quality control of ultrasound transducers: analysis of evaluation parameters and results of a survey of 116 transducers in a single hospital.

Authors:  P Cozzolino; R Stramare; A Udilano; M Castoro; E Scagliori; V Beltrame; L Rubaltelli
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

4.  The feasibility of implementation of ultrasound equipment standards set by United Kingdom professional bodies.

Authors:  Nicholas J Dudley; Debbie Harries; Jessica Wardle
Journal:  Ultrasound       Date:  2017-01-23

5.  Polydimethylsiloxane-based optical waveguides for tetherless powering of floating microstimulators.

Authors:  Ali Ersen; Mesut Sahin
Journal:  J Biomed Opt       Date:  2017-05-01       Impact factor: 3.170

6.  Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: a pilot ex vivo study.

Authors:  Mohammad Mehrmohammadi; Azra Alizad; Randall R Kinnick; Brian J Davis; Mostafa Fatemi
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

7.  Early experience with automated B-mode quality assurance tests.

Authors:  N J Dudley; N M Gibson
Journal:  Ultrasound       Date:  2013-12-19

8.  A simple method for determining the coagulation threshold temperature of transparent tissue-mimicking thermal therapy gel phantoms: Validated by magnetic resonance imaging thermometry.

Authors:  N Patrik Brodin; Ari Partanen; Patrik Asp; Craig A Branch; Chandan Guha; Wolfgang A Tomé
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

9.  Integrated Histotripsy and Bubble Coalescence Transducer for Thrombolysis.

Authors:  Aiwei Shi; Jonathan Lundt; Zilin Deng; Jonathan Macoskey; Hitinder Gurm; Gabe Owens; Xi Zhang; Timothy L Hall; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2018-09-30       Impact factor: 2.998

10.  Poly(vinyl alcohol) gel ultrasound phantom with durability and visibility of internal flow.

Authors:  Kenichi Funamoto; Osamu Yamashita; Toshiyuki Hayase
Journal:  J Med Ultrason (2001)       Date:  2014-08-05       Impact factor: 1.314

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.