Literature DB >> 12876701

Hyperpolarized 13C MR angiography using trueFISP.

Jonas Svensson1, Sven Månsson, Edvin Johansson, J Stefan Petersson, Lars E Olsson.   

Abstract

A (13)C-enriched water-soluble compound (bis-1,1-(hydroxymethyl)-1-(13)C-cyclopropane-D(8)), with a (13)C-concentration of approximately 200 mM, was hyperpolarized to approximately 15% using dynamic nuclear polarization, and then used as a contrast medium (CM) for contrast-enhanced magnetic resonance angiography (CE-MRA). The long relaxation times (in vitro: T(1) approximately 82 s, T(2) approximately 18 s; in vivo: T(1) approximately 38 s, T(2) approximately 1.3 s) are ideal for steady-state free precession (SSFP) imaging with a true fast imaging and steady precession (trueFISP) pulse sequence. It was shown both theoretically and experimentally that the optimal flip angle was 180 degrees. CE-MRA was performed in four anesthetized live rats after intravenous injection of 3 ml CM. The angiograms covered the thoracic/abdominal region in two of the animals, and the head-neck region in the other two. Fifteen consecutive images were acquired in each experiment, with a flip-back pulse at the end of each image acquisition. In the angiograms, the vena cava (SNR approximately 240), aorta, renal arteries, carotid arteries (SNR approximately 75), jugular veins, and several other vessels were visible. The SNR in the cardiac region was 500. Magnetization was preserved from one image acquisition to the next using the flip-back technique (SNR(cardiac) approximately 10 in the 15th image). Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12876701     DOI: 10.1002/mrm.10530

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  44 in total

1.  Investigating tumor perfusion and metabolism using multiple hyperpolarized (13)C compounds: HP001, pyruvate and urea.

Authors:  Cornelius von Morze; Peder E Z Larson; Simon Hu; Hikari A I Yoshihara; Robert A Bok; Andrei Goga; Jan Henrik Ardenkjaer-Larsen; Daniel B Vigneron
Journal:  Magn Reson Imaging       Date:  2011-12-12       Impact factor: 2.546

2.  Highly parallel volumetric imaging with a 32-element RF coil array.

Authors:  Yudong Zhu; Christopher J Hardy; Daniel K Sodickson; Randy O Giaquinto; Charles L Dumoulin; Gontran Kenwood; Thoralf Niendorf; Hubert Lejay; Charles A McKenzie; Michael A Ohliger; Neil M Rofsky
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

3.  Fast chemical shift mapping with multiecho balanced SSFP.

Authors:  Jochen Leupold; Oliver Wieben; Sven Månsson; Oliver Speck; Klaus Scheffler; J Stefan Petersson; Jürgen Hennig
Journal:  MAGMA       Date:  2006-11-22       Impact factor: 2.310

Review 4.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

5.  Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications.

Authors:  Daniel K Sodickson; Christopher J Hardy; Yudong Zhu; Randy O Giaquinto; Patrick Gross; Gontran Kenwood; Thoralf Niendorf; Hubert Lejay; Charles A McKenzie; Michael A Ohliger; Aaron K Grant; Neil M Rofsky
Journal:  Acad Radiol       Date:  2005-05       Impact factor: 3.173

Review 6.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

Review 7.  13C imaging-a new diagnostic platform.

Authors:  Sven Månsson; Edvin Johansson; Peter Magnusson; Chun-Ming Chai; Georg Hansson; J Stefan Petersson; Freddy Ståhlberg; Klaes Golman
Journal:  Eur Radiol       Date:  2005-06-14       Impact factor: 5.315

8.  Ultra-fast three dimensional imaging of hyperpolarized 13C in vivo.

Authors:  P Bhattacharya; K Harris; A P Lin; M Mansson; V A Norton; W H Perman; D P Weitekamp; B D Ross
Journal:  MAGMA       Date:  2005-11-23       Impact factor: 2.310

Review 9.  Interventional cardiovascular magnetic resonance imaging.

Authors:  Venkatesh K Raman; Robert J Lederman
Journal:  Trends Cardiovasc Med       Date:  2007-08       Impact factor: 6.677

10.  Handheld electromagnet carrier for transfer of hyperpolarized carbon-13 samples.

Authors:  Hong Shang; Timothy Skloss; Cornelius von Morze; Lucas Carvajal; Mark Van Criekinge; Eugene Milshteyn; Peder E Z Larson; Ralph E Hurd; Daniel B Vigneron
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.