Literature DB >> 12876035

Multidetector CT of bronchiectasis: effect of radiation dose on image quality.

Chin A Yi1, Kyung Soo Lee, Tae Sung Kim, Daehee Han, Yon Mi Sung, Seonwoo Kim.   

Abstract

OBJECTIVE: The purpose of our prospective study was to assess the image quality with respect to the radiation dose incurred by multidetector CT (MDCT) in patients with suspected bronchiectasis. SUBJECTS AND METHODS. Image clusters, composed of nine images, using MDCT (120 kVp, a 2.5-mm collimation, a pitch of 6, and 2.5-mm reconstruction intervals) were obtained at each of two levels-the azygous arch and the right inferior pulmonary vein-at 170, 100, 70, 40, 20, and 10 mA. Independently, two chest radiologists assessed and compared the quality of the images obtained at the six milliamperage exposures. Image quality was graded using a 5-point scale with lung and mediastinal window settings. Radiation doses were measured at each of the six milliamperage settings while scanning the whole lung of a thoracic phantom using MDCT.
RESULTS: The mean image quality scores at exposures of 170, 100, 70, 40, 20, 10 mA were as follows: 3.9, 3.7, 3.8, 3.2, 2.5, 1.6 at lung window settings and 4.1, 4.3, 4.0, 3.4, 2.3, 1.3 at mediastinal window settings, respectively. Images obtained at 70 mA were rated significantly better than those obtained at 40 mA or less (p < 0.01). The mean radiation dose at 170, 100, 70, 40, 20, 10 mA was 23.72, 14.39, 10.54, 5.41, 2.74, and 1.50 mGy, respectively.
CONCLUSION: With a tube current setting as low as 70 mA, MDCT provides images of acceptable quality and volumetric data sets for the evaluation of bronchiectasis. The trade-off of using MDCT rather than conventional high-resolution CT is that the radiation dose is five times higher with MDCT (10.54 mGy) than with conventional high-resolution CT (2.17 mGy with parameters of 120 kVp, 170 mA, 1-mm collimation, and 10-mm intervals).

Entities:  

Mesh:

Year:  2003        PMID: 12876035     DOI: 10.2214/ajr.181.2.1810501

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  7 in total

1.  Comparison between conventional interrupted high-resolution CT and volume multidetector CT acquisition in the assessment of bronchiectasis.

Authors:  L E Hill; G Ritchie; A J Wightman; A T Hill; J T Murchison
Journal:  Br J Radiol       Date:  2009-06-08       Impact factor: 3.039

Review 2.  CT protocols in interstitial lung diseases--a survey among members of the European Society of Thoracic Imaging and a review of the literature.

Authors:  Helmut Prosch; Cornelia M Schaefer-Prokop; Edith Eisenhuber; Daniela Kienzl; Christian J Herold
Journal:  Eur Radiol       Date:  2012-12-13       Impact factor: 5.315

3.  Pictorial essay: Allergic bronchopulmonary aspergillosis.

Authors:  Ritesh Agarwal; Ajmal Khan; Mandeep Garg; Ashutosh N Aggarwal; Dheeraj Gupta
Journal:  Indian J Radiol Imaging       Date:  2011-10

4.  Optimal dose levels in screening chest CT for unimpaired detection and volumetry of lung nodules, with and without computer assisted detection at minimal patient radiation.

Authors:  Andreas Christe; Zsolt Szucs-Farkas; Adrian Huber; Philipp Steiger; Lars Leidolt; Justus E Roos; Johannes Heverhagen; Lukas Ebner
Journal:  PLoS One       Date:  2013-12-26       Impact factor: 3.240

5.  Radiologist agreement on the quantification of bronchiectasis by high-resolution computed tomography.

Authors:  Milene Carneiro Barbosa de Brito; Maurício Kenji Ota; Fernando Sergio Studart Leitão Filho; Gustavo de Souza Portes Meirelles
Journal:  Radiol Bras       Date:  2017 Jan-Feb

Review 6.  Suspecting non-cystic fibrosis bronchiectasis: What the busy primary care clinician needs to know.

Authors:  Diego J Maselli; Bravein Amalakuhan; Holly Keyt; Alejandro A Diaz
Journal:  Int J Clin Pract       Date:  2017-02       Impact factor: 2.503

7.  Low dose chest CT protocol (50 mAs) as a routine protocol for comprehensive assessment of intrathoracic abnormality.

Authors:  Takeshi Kubo; Yoshiharu Ohno; Mizuki Nishino; Pei-Jan Lin; Shiva Gautam; Hans-Ulrich Kauczor; Hiroto Hatabu
Journal:  Eur J Radiol Open       Date:  2016-04-27
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.