Literature DB >> 12874191

Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts.

Gregg W Stone1, Campbell Rogers, James Hermiller, Robert Feldman, Patrick Hall, Robert Haber, A Masud, Patrick Cambier, Ron P Caputo, Mark Turco, Richard Kovach, Bruce Brodie, Howard C Herrmann, Richard E Kuntz, Jeffrey J Popma, Steve Ramee, David A Cox.   

Abstract

BACKGROUND: The high rate of periprocedural complications resulting from atherothrombotic embolization after percutaneous intervention in diseased saphenous vein grafts is reduced by distal microcirculatory protection using a balloon occlusion and aspiration system. Whether filter-based catheters, which offer the inherent advantages of maintained perfusion and ease of use, are as effective for this purpose has not been established. METHODS AND
RESULTS: A total of 651 patients undergoing percutaneous intervention of 682 saphenous vein graft lesions were prospectively randomized to distal protection with the filter-based FilterWire EX versus the GuardWire balloon occlusion and aspiration system. Device success was 95.5% and 97.2% with the FilterWire EX and GuardWire, respectively (P=0.25). Postprocedural measures of epicardial flow and angiographic complications were similar between the 2 groups, although bailout IIb/IIIa inhibitors were required slightly less frequently in the FilterWire EX group (0% versus 1.5%, P=0.03). The primary end point, the composite incidence of death, myocardial infarction, or target vessel revascularization at 30 days, occurred in 9.9% of FilterWire EX patients and 11.6% of GuardWire patients (difference [95% CI]=-1.7% [-6.4%, 3.1%]; P for superiority=0.53, P for noninferiority=0.0008).
CONCLUSIONS: Distal protection with the FilterWire EX may be safely used as an adjunct to percutaneous intervention of diseased saphenous vein grafts and, compared with distal protection with the GuardWire balloon occlusion and aspiration system, results in similar rates of major adverse cardiac events at 30 days.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12874191     DOI: 10.1161/01.CIR.0000080894.51311.0A

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  30 in total

1.  Clinical outcomes in patients with renal artery stenosis treated with stent placement with embolic protection compared with those treated with stent alone.

Authors:  Ankaj Khosla; Sanjay Misra; Eddie L Greene; Axel Pflueger; Steve C Textor; Haraldur Bjarnason; Michael A McKusick
Journal:  Vasc Endovascular Surg       Date:  2012-06-11       Impact factor: 1.089

Review 2.  Stenting of complex lesions: an overview.

Authors:  Usman Baber; Annapoorna S Kini; Samin K Sharma
Journal:  Nat Rev Cardiol       Date:  2010-09       Impact factor: 32.419

Review 3.  Secondary revascularization after CABG surgery.

Authors:  Javier Escaned
Journal:  Nat Rev Cardiol       Date:  2012-07-10       Impact factor: 32.419

4.  Percutaneous coronary intervention: recommendations for good practice and training.

Authors:  K D Dawkins; T Gershlick; M de Belder; A Chauhan; G Venn; P Schofield; D Smith; J Watkins; H H Gray
Journal:  Heart       Date:  2005-12       Impact factor: 5.994

5.  Implantation of paclitaxel-eluting stents in saphenous vein grafts: clinical and angiographic follow-up results from a multicentre study.

Authors:  Rainer Hoffmann; Tilmann Pohl; Ralf Köster; Ruediger Blindt; Peter Boeckstegers; Thomas Heitzer
Journal:  Heart       Date:  2006-08-29       Impact factor: 5.994

6.  Spontaneous slow flow in the saphenous vein graft: a relevant distinction of macrovascular endothelial dysfunction.

Authors:  Paul C Ho
Journal:  Heart Vessels       Date:  2007-07-20       Impact factor: 2.037

7.  Embolic protection device use in renal artery stent placement.

Authors:  Mallik R Thatipelli; Sanjay Misra; Srinivas R Sanikommu; Robert M Schainfeld; Sandeep K Sharma; Peter A Soukas
Journal:  J Vasc Interv Radiol       Date:  2009-03-27       Impact factor: 3.464

Review 8.  An update on coronary bypass graft intervention.

Authors:  Debabrata Dash
Journal:  Heart Asia       Date:  2014-03-06

9.  Carotid artery stenting in clinical practice results from the Carotid Artery Stenting (CAS)-registry of the Arbeitsgemeinschaft Leitende Kardiologische Krankenhausarzte (ALKK).

Authors:  R Zahn; E Roth; T Ischinger; B Mark; M Hochadel; U Zeymer; K Haerten; K E Hauptmann; E-R von Leitner; A Schramm; W Kasper; J Senges
Journal:  Z Kardiol       Date:  2005-03

Review 10.  Implementation of standardized assessment and reporting of myocardial infarction in contemporary randomized controlled trials: a systematic review.

Authors:  Sergio Leonardi; Paul W Armstrong; Phillip J Schulte; E Magnus Ohman; L Kristin Newby
Journal:  Eur Heart J       Date:  2013-01-25       Impact factor: 29.983

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.