Literature DB >> 12873576

Contrast radiology, computed tomography and ultrasonography in detecting internal fistulas and intra-abdominal abscesses in Crohn's disease: a prospective comparative study.

Giovanni Maconi1, Gianluca M Sampietro, Fabrizio Parente, Giovanni Pompili, Antonio Russo, Massimo Cristaldi, Giancarlo Arborio, Sandro Ardizzone, Giovanni Matacena, Angelo Maria Taschieri, Gabriele Bianchi Porro.   

Abstract

OBJECTIVE: Accurate assessment of intestinal complications of Crohn's disease (CD) is extremely important, both in clinical practice and in trials. The accuracy of radiographic and ultrasonographic diagnosis of internal fistulae and abscesses complicating CD is still debated and requires further investigation. We compared ultrasonography (US) and contrast radiography in detecting intestinal fistulae and abscesses complicating CD.
METHODS: A prospective study was carried out on 625 consecutive CD patients who underwent complete evaluation of the intestinal tract by means of colonoscopy and double contrast barium enema, small bowel enteroclysis, and abdominal ultrasound (US). Computed tomography (CT) was also carried out in cases of severe CD with clinical suspicion of septic complications. The accuracy of US, barium radiology, and CT in detecting internal fistulae and abscesses was assessed by comparing results with intraoperative findings in 128 consecutive patients who underwent operation immediately after diagnostic workup.
RESULTS: Internal fistulae and intra-abdominal abscesses were identified intraoperatively in 56 (43.7%) and 26 (20.3%) patients, respectively. Diagnostic accuracy of US and x-ray studies in detecting internal fistulae was comparable (85.2% vs 84.8%), with sensitivity of 71.4% for US and 69.6% for x-ray studies, and specificity of 95.8% for both. Combination of radiographic techniques and US significantly improved diagnostic accuracy in detection of internal fistulae. In severe cases of CD with clinical suspicion of septic complications such as abdominal mass or fever, the accuracy of US, barium studies, and CT was 88.5%, 80.3%, and 77%, respectively (p = ns). The presence of abscesses was correctly detected in 90.9% of cases by means of US and in 86.4% by CT (p = ns), although accuracy was higher for CT (91.8%) than for US (86.9%) because of false positive results in US studies.
CONCLUSIONS: Despite the fact that barium radiology is widely considered the method of choice in detection of internal fistulae, accuracy is not entirely satisfactory. Comparable accuracy was found for US and CT. The combination of barium and US studies, or the sole use of US in more CD patients with more severe disease, can reliably detect most internal fistulae and abscesses.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12873576     DOI: 10.1111/j.1572-0241.2003.07521.x

Source DB:  PubMed          Journal:  Am J Gastroenterol        ISSN: 0002-9270            Impact factor:   10.864


  48 in total

1.  A think tank of the Italian society of colorectal surgery (SICCR) on the surgical treatment of inflammatory bowel disease using the Delphi method: Crohn's disease.

Authors:  G Pellino; F Selvaggi; G Ghezzi; D Corona; G Riegler; G G Delaini
Journal:  Tech Coloproctol       Date:  2015-09-24       Impact factor: 3.781

2.  Contrast-enhanced ultrasonography (CEUS) vs. MRI of the small bowel in the evaluation of Crohn's disease activity.

Authors:  R Malagò; M D'Onofrio; W Mantovani; G D'Alpaos; G Foti; A Pezzato; G Caliari; D Cusumano; L Benini; R Pozzi Mucelli
Journal:  Radiol Med       Date:  2012-01-21       Impact factor: 3.469

Review 3.  Pediatric Small Bowel Crohn Disease: Correlation of US and MR Enterography.

Authors:  Jonathan R Dillman; Ethan A Smith; Ramon J Sanchez; Michael A DiPietro; Vera DeMatos-Maillard; Peter J Strouse; Kassa Darge
Journal:  Radiographics       Date:  2015-04-03       Impact factor: 5.333

4.  Magnetic resonance colonography for the detection of inflammatory diseases of the large bowel: quantifying the inflammatory activity.

Authors:  W M Ajaj; T C Lauenstein; G Pelster; G Gerken; S G Ruehm; J F Debatin; S C Goehde
Journal:  Gut       Date:  2005-02       Impact factor: 23.059

5.  [The value of postoperative ultrasonography].

Authors:  S Truong; J Grommes; J Conze; V Schumpelick
Journal:  Chirurg       Date:  2007-05       Impact factor: 0.955

6.  Combining two imaging techniques is best to diagnose small-bowel Crohn's disease.

Authors:  Giovanni Maconi; Gabriele Bianchi Porro
Journal:  Nat Clin Pract Gastroenterol Hepatol       Date:  2009-01-27

7.  Ultrasonographic findings in Crohn's disease.

Authors:  Gabriella Carnevale Maffè; Laura Brunetti; Pietro Formagnana; Gino Roberto Corazza
Journal:  J Ultrasound       Date:  2014-05-24

Review 8.  Surgery and diagnostic imaging in abdominal Crohn's disease.

Authors:  Fiorenzo Botti; Flavio Caprioli; Diego Pettinari; Alberto Carrara; Andrea Magarotto; Ettore Contessini Avesani
Journal:  J Ultrasound       Date:  2013-10-16

9.  High-output fistula.

Authors:  Naila Arebi; Alastair Forbes
Journal:  Clin Colon Rectal Surg       Date:  2004-05

10.  Diagnostic ionizing radiation exposure in a population-based cohort of patients with inflammatory bowel disease.

Authors:  Joanna M Peloquin; Darrell S Pardi; William J Sandborn; Joel G Fletcher; Cynthia H McCollough; Beth A Schueler; James A Kofler; Felicity T B Enders; Sara J Achenbach; Edward V Loftus
Journal:  Am J Gastroenterol       Date:  2008-06-28       Impact factor: 10.864

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.