Literature DB >> 12872277

Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard.

Mohammed Jemal1, Alan Schuster, Daisy B Whigan.   

Abstract

Selective, accurate, and reproducible liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of mevalonic acid, an intermediate in the biosynthesis of cholesterol and therefore a useful biomarker in the development of cholesterol lowering drugs, in human plasma and urine. A hepta-deuterated analog of mevalonic acid was used as the internal standard. For both methods, calibration standards were prepared in water, instead of human plasma and urine, due to unacceptably high levels of endogenous mevalonic acid. The lower quality control (QC) samples were prepared in water while the higher QC samples were prepared in the biological matrices. For the isolation/purification of mevalonic acid from the plasma and urine matrices, the samples were first acidified to convert the acid analyte into its lactone form. For the plasma samples, the lactone analyte was retained on and then eluted off a polymeric solid-phase extraction (SPE) sorbent. For the urine method, the sample containing the lactone analyte was passed through a C-18 SPE column, which did not retain the analyte, with the subsequent analyte retention on and then elution off a polymeric SPE sorbent. Chromatographic separation was achieved isocratically on a polar-endcapped C-18 analytical column with a water/methanol mobile phase containing 0.5 mM formic acid. Detection was by negative-ion electrospray tandem mass spectrometry. The standard curve range was 0.500-20.0 ng/mL for the plasma method and 25.0-1,000 ng/mL for the urine method. Excellent accuracy and precision were obtained for both methods at all concentration levels tested. It was interesting to note that for certain batches of urine, when a larger sample volume was used for analysis, a high degree of matrix effect was observed which resulted not only in the attenuation of the absolute response, but also in a change of analyte/internal standard response ratio. This demonstrated that, under certain conditions, the use of a stable isotope analog internal standard does not, contrary to conventional thinking, guarantee the constancy of the analyte/internal response ratio, which is a prerequisite for a rugged bioanalytical method. On the other hand, under conditions where the sample matrix does not have such a deleterious effect, we have found that a stable isotope analog could serve as a surrogate (substitute) analyte. Thus, we have shown that using calibration standards prepared by spiking plasma with tri-deuterated or tetra-deuterated mevalonic acid, instead of mevalonic acid itself (the analyte), plasma QC samples that contain mevalonic acid can be successfully analyzed for the accurate and precise quantitation of mevalonic acid. The use of a surrogate analyte provides the opportunity to gauge the daily performance of the method for the low concentration levels prepared in the biological matrix, which otherwise is not achievable because of the endogenous concentrations of the analyte in the biological matrices. Copyright 2003 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12872277     DOI: 10.1002/rcm.1112

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  18 in total

1.  Isoprenoid quantitation in human brain tissue: a validated HPLC-fluorescence detection method for endogenous farnesyl- (FPP) and geranylgeranylpyrophosphate (GGPP).

Authors:  Gero P Hooff; Dietrich A Volmer; W Gibson Wood; Walter E Müller; Gunter P Eckert
Journal:  Anal Bioanal Chem       Date:  2008-08-09       Impact factor: 4.142

2.  Reverse-polynomial dilution calibration methodology extends lower limit of quantification and reduces relative residual error in targeted peptide measurements in blood plasma.

Authors:  Yunki Y Yau; Xizi Duo; Rupert W L Leong; Valerie C Wasinger
Journal:  Mol Cell Proteomics       Date:  2014-12-09       Impact factor: 5.911

3.  Accurate quantification of PGE2 in the polyposis in rat colon (Pirc) model by surrogate analyte-based UPLC-MS/MS.

Authors:  Changhong Yun; Wan-Mohaiza Dashwood; Lawrence N Kwong; Song Gao; Taijun Yin; Qinglan Ling; Rashim Singh; Roderick H Dashwood; Ming Hu
Journal:  J Pharm Biomed Anal       Date:  2017-07-25       Impact factor: 3.935

4.  Absolute Quantification of Aβ1-42 in CSF Using a Mass Spectrometric Reference Measurement Procedure.

Authors:  Josef Pannee; Kaj Blennow; Henrik Zetterberg; Erik Portelius
Journal:  J Vis Exp       Date:  2017-03-21       Impact factor: 1.355

5.  A simple LC-MS/MS method for determination of kynurenine and tryptophan concentrations in human plasma from HIV-infected patients.

Authors:  Yong Huang; Alexander Louie; Qiyun Yang; Nicholas Massenkoff; Connie Xu; Peter W Hunt; Winnie Gee
Journal:  Bioanalysis       Date:  2013-06       Impact factor: 2.681

6.  An ultrasensitive enzymatic method for measuring mevalonic acid in serum.

Authors:  Takeshi Matsuoka; Shigeru Ueda; Hideyuki Matsumoto; Masanobu Kawakami
Journal:  J Lipid Res       Date:  2012-06-19       Impact factor: 5.922

7.  Comparative triplex tandem mass spectrometry assays of lysosomal enzyme activities in dried blood spots using fast liquid chromatography: application to newborn screening of Pompe, Fabry, and Hurler diseases.

Authors:  Zdeněk Spáčil; Susan Elliott; Steven L Reeber; Michael H Gelb; C Ronald Scott; František Tureček
Journal:  Anal Chem       Date:  2011-05-17       Impact factor: 6.986

8.  Detection of nonsterol isoprenoids by HPLC-MS/MS.

Authors:  Linda Henneman; Arno G van Cruchten; Simone W Denis; Michael W Amolins; Andrew T Placzek; Richard A Gibbs; Willem Kulik; Hans R Waterham
Journal:  Anal Biochem       Date:  2008-08-30       Impact factor: 3.365

Review 9.  Steroid assays in paediatric endocrinology.

Authors:  John W Honour
Journal:  J Clin Res Pediatr Endocrinol       Date:  2010-02-01

10.  Determination of key intermediates in cholesterol and bile acid biosynthesis by stable isotope dilution mass spectrometry.

Authors:  Tadashi Yoshida; Akira Honda; Hiroshi Miyazaki; Yasushi Matsuzaki
Journal:  Anal Chem Insights       Date:  2008-03-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.