Literature DB >> 12860901

Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases.

Pedro A Lemos1, Francesco Saia, Jurgen M R Ligthart, Chourmouzios A Arampatzis, Georgios Sianos, Kengo Tanabe, Angela Hoye, Muzaffer Degertekin, Joost Daemen, Eugene McFadden, Sjoerd Hofma, Pieter C Smits, Pim de Feyter, Willem J van der Giessen, Ron T van Domburg, Patrick W Serruys.   

Abstract

BACKGROUND: We describe the clinical and morphological patterns of restenosis after sirolimus-eluting stent (SES) implantation. METHODS AND
RESULTS: From 121 patients with coronary angiography obtained >30 days after SES implantation, restenosis (diameter stenosis >50%) was identified in 19 patients and 20 lesions (located at the proximal 5-mm segment in 30% or within the stent in 70%). Residual dissection after the procedure or balloon trauma outside the stent was identified in 83% of the proximal edge lesions. Lesions within the stent were focal, and stent discontinuity was identified in some lesions evaluated by intravascular ultrasound.
CONCLUSIONS: Sirolimus-eluting stent edge restenosis is frequently associated with local trauma outside the stent. In-stent restenosis occurs as a localized lesion, commonly associated with a discontinuity in stent coverage. Local conditions instead of intrinsic drug-resistance to sirolimus are likely to play a major role in post-SES restenosis.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12860901     DOI: 10.1161/01.CIR.0000083366.33686.11

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  32 in total

1.  Long-term angiographic outcomes of post-sirolimus-eluting stent restenosis in Japanese patients.

Authors:  Nobuyuki Miyai; Noriyuki Kinoshita; Keisuke Oota; Takeshi Yamada; Reo Nakamura; Hidekazu Irie; Tetsuo Hashimoto; Shyunichi Tamaki; Hiroaki Matsubara
Journal:  Heart Vessels       Date:  2010-10-27       Impact factor: 2.037

2.  Regulation of vascular smooth muscle cell growth: targeting the final common pathway.

Authors:  Angela M Taylor; Coleen A McNamara
Journal:  Arterioscler Thromb Vasc Biol       Date:  2003-10-01       Impact factor: 8.311

3.  Late incomplete lesion coverage following Cypher stent deployment for diffuse right coronary artery stenosis.

Authors:  A Halkin; S Carlier; M B Leon
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

4.  Characterizing the spectrum of in-stent restenosis: implications for contemporary treatment.

Authors:  Gordon E Pate; May Lee; Karin Humphries; Eric Cohen; Robert Lowe; Rebecca S Fox; Robert Teskey; Christopher E Buller
Journal:  Can J Cardiol       Date:  2006-12       Impact factor: 5.223

5.  Superiority of sirolimus eluting stent compared with intracoronary beta radiation for treatment of in-stent restenosis: a matched comparison.

Authors:  E Iofina; P W Radke; P Skurzewski; P K Haager; R Blindt; K-C Koch; P Hanrath; J vom Dahl; R Hoffmann
Journal:  Heart       Date:  2005-03-29       Impact factor: 5.994

6.  Long-term inhibition of intimal hyperplasia using vascular photodynamic therapy in balloon-injured carotid arteries.

Authors:  Takeshi Wakamatsu; Takashi Saito; Junichi Hayashi; Toshiaki Takeichi; Kiyoshi Kitamoto; Katsuo Aizawa
Journal:  Med Mol Morphol       Date:  2005-12       Impact factor: 2.309

7.  Three-dimensional coronary imaging for the ostium of the left anterior descending artery.

Authors:  Kenji Sadamatsu; Shuichiro Sagara; Tohru Yamawaki; Hideki Tashiro
Journal:  Int J Cardiovasc Imaging       Date:  2008-11-26       Impact factor: 2.357

8.  Difference in neointimal coverage at chronic stage between bare metal stent and sirolimus-eluting stent evaluated at stent-strut level by optical coherence tomography.

Authors:  Shinichiro Ikuta; Kazuhiro Kobuke; Yoshitaka Iwanaga; Yoshifumi Nakauchi; Kenji Yamaji; Shunichi Miyazaki
Journal:  Heart Vessels       Date:  2013-06-21       Impact factor: 2.037

Review 9.  Are we aware of stent fracture?

Authors:  R D Acar; M Bulut; M Akcakoyun
Journal:  Herz       Date:  2013-10-25       Impact factor: 1.443

10.  Stent implant follow-up in intravascular optical coherence tomography images.

Authors:  Gozde Unal; Serhan Gurmeric; Stéphane Guy Carlier
Journal:  Int J Cardiovasc Imaging       Date:  2009-09-24       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.