Literature DB >> 12852901

Single point measurements of magnetic field gradient waveform.

David J Goodyear1, Maurice Shea, Steven D Beyea, Nadim J Shah, Bruce J Balcom.   

Abstract

Pulsed magnetic field gradients are fundamental to spatial encoding and diffusion weighting in magnetic resonance. The ideal pulsed magnetic field gradient should have negligible rise and fall times, however, there are physical limits to how fast the magnetic field gradient may change with time. Finite gradient switching times, and transient, secondary, induced magnetic field gradients (eddy currents) alter the ideal gradient waveform and may introduce a variety of undesirable image artifacts. We have developed a new method to measure the complete magnetic field gradient waveform. The measurement employs a heavily doped test sample with short MR relaxation times (T(1), T(2), and T(2)(*)<100 micros) and a series of closely spaced broadband radiofrequency excitations, combined with single point data acquisition. This technique, a measure of evolving signal phase, directly determines the magnetic field gradient waveform experienced by the test sample. The measurement is sensitive to low level transient magnetic fields produced by eddy currents and other short and long time constant non-ideal gradient waveform behaviors. Data analysis is particularly facile permitting a very ready experimental check of gradient performance.

Mesh:

Substances:

Year:  2003        PMID: 12852901     DOI: 10.1016/s1090-7807(03)00152-6

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  4 in total

1.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

2.  Eddy current compensation for delta relaxation enhanced MR by dynamic reference phase modulation.

Authors:  Uvo Christoph Hoelscher; Peter M Jakob
Journal:  MAGMA       Date:  2012-08-24       Impact factor: 2.310

3.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

4.  VERSE-guided parallel RF excitations using dynamic field correction.

Authors:  Mustafa Çavuşoğlu; Ronald Mooiweer; Klaas P Pruessmann; Shaihan J Malik
Journal:  NMR Biomed       Date:  2017-02-17       Impact factor: 4.044

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.