Literature DB >> 12846775

The effect of PMMA-based protein-leaking dialyzers on plasma homocysteine levels.

Francesco Galli1, Serena Benedetti, Umberto Buoncristiani, Marta Piroddi, Carmela Conte, Franco Canestrari, Emanuela Buoncristiani, Ardesio Floridi.   

Abstract

BACKGROUND: Hyperhomocysteinemia is a well-recognized independent risk factor for cardiovascular disease in end-stage renal disease (ESRD) patients. Since homocysteine (Hcy) largely binds to serum proteins (80 to 90%), in this study we investigated the possibility that polymethylmethacrylate (PMMA)-based protein-leaking dialyzers could reduce total plasma Hcy (tHcy) levels in ESRD patients.
METHODS: Two matched groups of patients (N = 13) showing mild to intermediate hyperhomocysteinemia on standard hemodialysis (HD) with conventional non-protein-leaking dialyzers were included. In the control group membranes were maintained the same, while the study group was switched to protein-leaking dialyzers (BK-F series; Toray, Japan) and studied for 6 months. tHcy was measured by high performance liquid chromatography (HPLC) at baseline and after 1, 3, and 6 months. Proteins and Hcy were also measured in the spent dialysate.
RESULTS: The pre-HD levels of tHcy in the control group remained close to baseline values (26.6 +/- 5.0 micromol/L), while in the study group at 1, 3, and 6 months they decreased from a baseline value (in micrormol/L) of 25.3 +/- 5.9 to 21.5 +/- 4.5, 16.9 +/- 4.0, and 17.2 +/- 4.2, respectively (P < 0.01 for values at 3 and 6 months vs. baseline). The intra-HD drop of tHcy (Delta HDHcy) slightly but progressively decreased during the 3 steps on protein-leaking dialyzers and a positive correlation was found between Delta HDHcy and pre-HD levels of tHcy. In spent dialysate samples from protein-leaking dialyzer-treated patients, the amount of protein-bound Hcy (bHcy) was approximately 10 times higher than in non-protein-leaking dialyzers, but the Delta HDHcy observed in non-protein-leaking dialyzers and protein-leaking dialyzers was comparable. Serum proteins and albumin were only slightly affected by protein-leaking dialyzers.
CONCLUSION: This study demonstrates that protein-leaking dialyzers used with a pure diffusive technique significantly lower pre-HD tHcy (approximately 33% of starting levels after 3 months of treatment) in ESRD patients. A possible underlying mechanism for this effect could be the removal of large molecular weight solutes responsible for a defective metabolism of the Hcy, as the removal of bHcy with protein-leaking dialyzers seems not sufficient, per se, to explain this steady reduction of tHcy levels in pre-HD.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12846775     DOI: 10.1046/j.1523-1755.2003.00134.x

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  5 in total

Review 1.  Enhancing dialyser clearance-from target to development.

Authors:  Kamonwan Tangvoraphonkchai; Andrew Davenport
Journal:  Pediatr Nephrol       Date:  2017-04-12       Impact factor: 3.714

2.  Relation of kidney function and homocysteine in patients with hypothyroidism.

Authors:  Qingrong Pan; Shuxin Gao; Xia Gao; Ning Yang; Zhi Yao; Yanjin Hu; Li Miao; Zhe Chen; Guang Wang
Journal:  Endocr Connect       Date:  2021-05-13       Impact factor: 3.335

3.  Elevated plasma free thiols are associated with early and one-year graft function in renal transplant recipients.

Authors:  Marie B Nielsen; Bente Jespersen; Henrik Birn; Nicoline V Krogstrup; Arno R Bourgonje; Henri G D Leuvenink; Harry van Goor; Rikke Nørregaard
Journal:  PLoS One       Date:  2021-08-11       Impact factor: 3.240

4.  Potential role of the soluble form of CD40 in deficient immunological function of dialysis patients: new findings of its amelioration using polymethylmethacrylate (PMMA) membrane.

Authors:  Cécile Contin-Bordes; Adeline Lacraz; Valérie de Précigout
Journal:  NDT Plus       Date:  2010-05

Review 5.  Current approaches to middle molecule removal: room for innovation.

Authors:  Ikuto Masakane; Kenji Sakurai
Journal:  Nephrol Dial Transplant       Date:  2018-10-01       Impact factor: 5.992

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.