Literature DB >> 12843232

Automated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT.

Piotr J Slomka1, Damini Dey, Christian Przetak, Usaf E Aladl, Richard P Baum.   

Abstract

UNLABELLED: Image registration and fusion of whole-body (18)F-FDG PET with thoracic CT would allow combination of anatomic detail from CT with functional PET information, which could lead to improved diagnosis or PET-based radiotherapy planning.
METHODS: We have designed a practical and fully automated algorithm for the elastic 3-dimensional image registration of whole-body PET and CT images, which compensates for the nonlinear deformation due to breath-hold CT imaging. A set of 18 PET and CT patient datasets has been evaluated by the algorithm. Initially, a 9-parameter linear registration is performed by maximizing the mutual information (MI)-based cost function, between the CT and the combination of emission and transmission PET volumes, using progressively increased matrix sizes to increase speed and provide better convergence. Subsequently, lung contours on transmission maps and corresponding contours on CT volumes are automatically detected. A large number (few hundreds) of corresponding point pairs are automatically derived, defining a thin-plate-spline (TPS) elastic transformation of PET emission and transmission scans to match the CT scan.
RESULTS: In all 18 patients the automatic linear registration with multiresolution converged close to the final alignment, but, in 10 cases, the nonlinear differences in the diaphragm position and chest wall were still clearly visible. The nonlinear adjustment, which was in the order of 40-75 mm, significantly improved the alignment between breath-hold CT and PET, especially in the areas of the diaphragm. Lung volumes measured from transmission and CT scans match closely after the warping has been applied. The average computation time is <40 s for the linear component and <30 s for the nonlinear component for a typical PET scan with 4-6 bed positions.
CONCLUSION: We have developed a technique for automatic nonlinear registration of CT and PET whole-body images to common spatial coordinates. This technique may be applied for automatic fusion of PET with CT acquired on stand-alone scanners during normal breathing or breath-hold data acquisition.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12843232

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  19 in total

1.  The new-generation positron emission tomography/computed tomography scanners: implications for cardiac imaging.

Authors:  Stephen L Bacharach
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

2.  Is PET/CT necessary in paediatric oncology? For.

Authors:  Christiane Franzius; Kai Uwe Juergens; Otmar Schober
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-08       Impact factor: 9.236

3.  Software-based fusion of PET and CT images for suspected recurrent lung cancer.

Authors:  Yuji Nakamoto; Michio Senda; Tomohisa Okada; Setsu Sakamoto; Tsuneo Saga; Tatsuya Higashi; Kaori Togashi
Journal:  Mol Imaging Biol       Date:  2008-02-22       Impact factor: 3.488

4.  Incorporation of preprocedural PET into CT-guided radiofrequency ablation of hepatic metastases: a nonrigid image registration validation study.

Authors:  Peng Lei; Omkar Dandekar; David Widlus; Raj Shekhar
Journal:  J Digit Imaging       Date:  2009-05-27       Impact factor: 4.056

Review 5.  Multimodality image registration with software: state-of-the-art.

Authors:  Piotr J Slomka; Richard P Baum
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

6.  Dual-isotope acquisition for CT-SPECT registration of infection studies.

Authors:  Lisa Tang; Ghassan Hamarneh; Anna Celler
Journal:  J Digit Imaging       Date:  2009-01-10       Impact factor: 4.056

7.  Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-12       Impact factor: 9.236

8.  FDG-PET reveals improved cardiac regeneration and attenuated adverse remodelling following Sitagliptin + G-CSF therapy after acute myocardial infarction.

Authors:  Lisa Gross; Lisa Paintmayer; Sebastian Lehner; Lydia Brandl; Christoph Brenner; Ulrich Grabmaier; Bruno Huber; Peter Bartenstein; Hans-Diogenes Theiss; Wolfgang-Michael Franz; Steffen Massberg; Andrei Todica; Stefan Brunner
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-09-28       Impact factor: 6.875

9.  Impact of rigid and nonrigid registration on the determination of 18F-FDG PET-based tumour volume and standardized uptake value in patients with lung cancer.

Authors:  Aleksandar Grgic; Elena Ballek; Jochen Fleckenstein; Norbert Moca; Stephanie Kremp; Andrea Schaefer; Jan-Martin Kuhnigk; Christian Rübe; Carl-Martin Kirsch; Dirk Hellwig
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01-22       Impact factor: 9.236

10.  Quantitative analysis of myocardial perfusion SPECT anatomically guided by coregistered 64-slice coronary CT angiography.

Authors:  Piotr J Slomka; Victor Y Cheng; Damini Dey; Jonghye Woo; Amit Ramesh; Serge Van Kriekinge; Yasuzuki Suzuki; Yaron Elad; Ronald Karlsberg; Daniel S Berman; Guido Germano
Journal:  J Nucl Med       Date:  2009-09-16       Impact factor: 10.057

View more