Ventricular constraint in severe heart failure halts decline in cardiovascular function associated with experimental dilated cardiomyopathy.

Jai S Raman1, Melissa J Byrne, John M Power, Clif A Alferness.   

Abstract

BACKGROUND: We have shown that passive ventricular constraint during moderate heart failure can halt progressive deterioration in cardiac function in an experimental model of ovine pacing induced heart failure (HF). We report on ventricular constraint in severe heart failure.
METHODS: Eighteen adult merino sheep were used. Severe heart failure was induced in two stages, ie, high rate ventricular pacing for 21 days to produce moderate HF and then for 42 days to induce severe HF. A custom-made polyester mesh cardiac support device ([CSD] Acorn Cardiovascular, St Paul, MN) was implanted snugly around both ventricles through a lower partial sternotomy in 9 sheep (group 1). Rapid ventricular pacing was continued for a further 28 days in all animals to induce advanced HF. Cardiovascular functional indicators were determined using echocardiography and a submaximal treadmill exercise protocol at base line, moderate, severe, and advanced stages. The 9 sheep in group 2 were used as controls.
RESULTS: Cardiovascular function was significantly depressed in all animals in advanced heart failure compared with base line, with left ventricular ejection fraction (LVEF) falling from 50% to 25% (p < 0.05) and LV +dp/dt((max)) declining from 1,777 to 1,243 (p < 0.05). However after CSD implantation cardiovascular function during exercise improved significantly despite ongoing rapid pacing, with LVEF increasing to 30% and LV +dp/dt to 1,499 (p < 0.05) in group 1. There were no significant changes in left ventricular long axis area (157 to 151 cm(2)) and short axis (6.8 to 6.1 cm) dimensions at the termination of pacing compared with those at time of CSD implant. Mitral regurgitation improved slightly from 2.5 to 2.19 after containment (p < 0.05) in group 1 but increased to 2.83 in group 2.
CONCLUSIONS: Ventricular constraint in advanced heart failure with a custom-made polyester mesh device halted the decline in cardiac function seen in untreated animals with this pacing-induced animal model of heart failure. These results indicate potential clinical implications for ventricular containment in the treatment of end-stage heart failure.

Entities:  

Mesh:

Year:  2003        PMID: 12842528     DOI: 10.1016/s0003-4975(03)00185-1

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  5 in total

1.  Efficacy of the Acorn Cardiac Support Device in animals with heart failure secondary to high rate pacing.

Authors:  John M Power; Jai Raman; Melissa J Byrne; Clif A Alferness
Journal:  Heart Fail Rev       Date:  2005-06       Impact factor: 4.214

Review 2.  Global left ventricular remodeling with the Acorn Cardiac Support Device: hemodynamic and angiographic findings in dogs with heart failure.

Authors:  Hani N Sabbah
Journal:  Heart Fail Rev       Date:  2005-06       Impact factor: 4.214

Review 3.  Device therapy for remodeling in congestive heart failure.

Authors:  Edward A Carraway; Barry K Rayburn
Journal:  Curr Heart Fail Rep       Date:  2007-03

Review 4.  Diastolic ventricular support with cardiac support devices: an alternative approach to prevent adverse ventricular remodeling.

Authors:  Pavan Atluri; Michael A Acker
Journal:  Heart Fail Rev       Date:  2013-01       Impact factor: 4.214

5.  Beneficial effects of a cardiac support device on left ventricular remodeling after posterior myocardial infarction: an evaluation by echocardiography, pressure-volume curves and ventricular histology.

Authors:  Miyako Okada; Toshiaki Akita; Fumito Mizuno; Asami Nakayama; Kouichi Morioka
Journal:  Surg Today       Date:  2015-08-02       Impact factor: 2.549