Clinical evaluation of chirp-coded excitation in medical ultrasound.

Morten H Pedersen1, Thanassis X Misaridis, Jørgen A Jensen.   

Abstract

Despite the enormous development in medical ultrasound (US) imaging over the last decades, penetration depth with satisfying image quality is often a problem in clinical practice. Coded excitation, used for years in radar techniques to increase signal-to-noise ratio (SNR), has recently been introduced in medical US scanning. In the present study, coded excitation using frequency-modulated US signals is implemented and evaluated in vivo.A total of nine male volunteers were scanned in three different abdominal locations, using both conventional pulsed and coded excitation. A modified scanner (B-K Medical model 3535) with transmitter and receiver boards developed in our group and a mechanical 4 MHz transducer were used. The system acquired coded and conventional US image frames interleaved, yielding identical acquisitions with the two techniques. Cine-loop sequences were evaluated by three experienced sonographers estimating penetration depth and scoring image quality of both conventional and coded imaging. The results showed a significant (p < 0.001) increase in penetration depth around 2 cm. Image quality was significantly (p < 0.001) better using codes at full usable depth and slightly, but also significantly (p < 0.05), better above depths, where the effect of coded excitation was noticeable to the sonographers. We conclude that the higher SNR offered by coded excitation gives improved image quality and provides increased penetration in medical US imaging. This increased SNR can, alternatively, be used to allow imaging at higher frequencies and thereby increase spatial resolution without any loss of penetration.

Mesh:

Year:  2003        PMID: 12837505     DOI: 10.1016/s0301-5629(02)00784-6

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  10 in total

1.  Spectral image reconstruction for transcranial ultrasound measurement.

Authors:  Greg T Clement
Journal:  Phys Med Biol       Date:  2005-11-16       Impact factor: 3.609

2.  Modeling and phantom studies of ultrasonic wall shear rate measurements using coded pulse excitation.

Authors:  Jean K Tsou; Jie Liu; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-04       Impact factor: 2.725

3.  Observation of contrast agent response to chirp insonation with a simultaneous optical-acoustical system.

Authors:  Yang Sun; Shukui Zhao; Paul A Dayton; Katherine W Ferrara
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-06       Impact factor: 2.725

4.  Characterization of the trabecular bone structure using frequency modulated ultrasound pulse.

Authors:  Wei Lin; Yi Xia; Yi-Xian Qin
Journal:  J Acoust Soc Am       Date:  2009-06       Impact factor: 1.840

5.  Coded Spectral Doppler Imaging: From Simulation to Real-Time Processing.

Authors:  Alessandro Ramalli; Enrico Boni; Alessandro Dallai; Francesco Guidi; Stefano Ricci; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-05-26       Impact factor: 2.725

6.  Chirp- and random-based coded ultrasonic excitation for localized blood-brain barrier opening.

Authors:  H A S Kamimura; S Wang; S-Y Wu; M E Karakatsani; C Acosta; A A O Carneiro; E E Konofagou
Journal:  Phys Med Biol       Date:  2015-10-07       Impact factor: 3.609

7.  Assessing Stability of Crutch Users by Non-Contact Methods.

Authors:  Achilles Vairis; Suzana Brown; Maurice Bess; Kyu Hyun Bae; Jonathan Boyack
Journal:  Int J Environ Res Public Health       Date:  2021-03-15       Impact factor: 3.390

8.  High resolution transcranial acoustoelectric imaging of current densities from a directional deep brain stimulator.

Authors:  Chet Preston; Alexander M Alvarez; Andres Barragan; Jennifer Becker; Willard S Kasoff; Russell S Witte
Journal:  J Neural Eng       Date:  2020-02-27       Impact factor: 5.379

9.  Frequency-Dependent Spatial Coherence in Conventional and Chirp Transmissions.

Authors:  James Long; Nick Bottenus; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-04-26       Impact factor: 2.725

10.  Ultrasound Elasticity Imaging System with Chirp-Coded Excitation for Assessing Biomechanical Properties of Elasticity Phantom.

Authors:  Guan-Chun Chun; Hsing-Jung Chiang; Kuan-Hung Lin; Chien-Ming Li; Pei-Jarn Chen; Tainsong Chen
Journal:  Materials (Basel)       Date:  2015-12-03       Impact factor: 3.623

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.